ABB - Installation Products 655CETP-K0330-DRG - 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products 655CETP-K0330-DRG 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and…

UPC: 075114181860


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655CETP-K0330-DRG is a 600 Amp, 15kV Combo T Elbow Reducing Tap Plug kit designed for medium-voltage cable connections in power distribution networks. This complete kit includes a stud, cable adapter, lug, and insulated cap, eliminating the need for separate test points. Manufactured from durable aluminum, the plug accommodates cable insulation diameters from 1.090 inches to 1.310 inches and supports conductor sizes including 500 kcmil (compressed stranded), 600 kcmil (compacted solid), and 250/300 mm² (compact). The reducing tap plug design minimizes inventory requirements by supporting multiple cable sizes. Key features include a 2.67-inch stack height reduction per elbow/connecting plug, a simple connection system that reduces cross-threading risks, and easier alignment during installation. The kit installs using standard assembly tools and includes an internal hex broach for proper installation torque. The IEEE 386 color-coded PBT interface enhances visibility, provides a seating indicator, and reduces sticking. Electrical ratings meet ANSI/IEEE Standard 386 for 15kV systems, with a maximum phase-to-ground operating voltage of 8.3kV, phase-to-phase voltage of 14.4kV, and a 95kV BIL impulse withstand. The loadbreak interface supports 200A continuous and loadbreak operations, while the deadbreak connection handles 600A continuous. Momentary and fault close ratings include 10kA symmetrical for 10 cycles and 25kA symmetrical for 10 cycles. Applications include medium-voltage power distribution systems requiring reliable cable connections. The hollow bore of the ComboT allows visual validation of the compression lug position before final assembly, ensuring proper installation. The ⅝” – 11 stud threads into the equipment bushing, and the design supports both stud-first and snuffer/bus-first installation methods.
  • 600 Amp, 15kV rated for medium-voltage cable connections
  • Supports cable insulation diameters from 1.090" to 1.310"
  • Compatible with 500 kcmil (compressed stranded), 600 kcmil (compacted solid), and 250/300 mm² (compact) conductors
  • Includes stud, cable adapter, lug, and insulated cap kit (no test point required)
  • Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand rating

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K675LR-M2330

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
15kv, 600 Amp, Combo T Connector with Bus, Stud, Cable Adapter and Aluminum Lug, No Test Point, includes Insulated Cap, Cable Insulation Diameter .760-.950 inches, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.

655CETP-G0250-DRG

15kv, 600 Amp, Combo T Connector with Bus, Stud, Cable Adapter and Aluminum Lug, No Test Point, includes Insulated Cap, Cable Insulation Diameter .760-.950 inches, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.
15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil. Includes Insulated cap

655CETP-K0300-DRG

15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil. Includes Insulated cap
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug, No Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. With Insulated Cap

655CETP-J5300-DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug, No Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. With Insulated Cap
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap and Shrink-Fit Jacket Seal Kit

K656CETP-P0410-DRGS

15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap and Shrink-Fit Jacket Seal Kit
200 Amp LoadBreak Replacement Elbow without Test point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

167RLR-H-5260

200 Amp LoadBreak Replacement Elbow without Test point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
600 Amp, 15KV, Combo T Elbow Reducing Tap Plug with stud, cable adapter, Lug and Insulated Cap kit, No Test Point, Cable Insulation Diameter Range - 1.180 ti 1.465 inches, Connector Type - Universal Aluminum, Connector Size - AWG or Kcmil - Stranded Compressed 500, Solid/Compact 600, MMSQ Compact only 300.

655CETPL0330

600 Amp, 15KV, Combo T Elbow Reducing Tap Plug with stud, cable adapter, Lug and Insulated Cap kit, No Test Point, Cable Insulation Diameter Range - 1.180 ti 1.465 inches, Connector Type - Universal Aluminum, Connector Size - AWG or Kcmil - Stranded Compressed 500, Solid/Compact 600, MMSQ Compact only 300.
15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 kcmil or Solid/Compact 900 kcmil.

K655CETP-M0380

15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 kcmil or Solid/Compact 900 kcmil.

Frequently Asked Questions

What cable insulation diameters does this tap plug support?

It supports cable insulation diameters from 1.090 inch to 1.310 inch.

Does this kit include a test point?

No, the kit does not include a test point.

What material is the tap plug made from?

The tap plug is constructed from aluminum.

What is the maximum operating voltage for this tap plug?

The device is rated for 15kV maximum operating voltage.

What conductor sizes are compatible with this tap plug?

Compatible conductor sizes include AWG or kcmil (500 compressed stranded, 600 compacted solid), and mm² compact (250/300).

Is this tap plug suitable for outdoor installations?

The product is designed for medium-voltage cable systems but does not specify outdoor suitability; consult ABB documentation for environmental ratings.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides detailed instructions for the installation and setup of 655/656/675/676CETP Deadbreak Elbow Connectors, designed for fully shielded, submersible high voltage cable connections, ensuring safe and reliable operation.

Estimated time: 1h 30m

Tools needed:

600AT or 600ATM assembly tool, Hotstick, Wire brush (for aluminum conductors), Crimping tool, Wire strippers, Measuring tape or ruler, Suitable sensing device (for capacitive test points)

Supplies needed:

655/656/675/676CETP Deadbreak Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Lubricant), Ground wire (at least No. 14 AWG Copper), Suitable grounding connector, Vinyl plastic tape, Tape retainer (if applicable), Tape marker (if applicable), HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone grease, DR(G), ESA, GLR, or LR (mating connector/accessory, if applicable)

  1. De-energize Apparatus and Prepare Work Area

    WARNING: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Ensure all work is performed in accordance with user, local, and national work rules. Inspect all parts for damage, rating, and compatibility before starting. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors.

  2. Position Cable and Clean Outer Surface

    Position the cable in its final assembled location with enough slack to allow for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.

  3. Prepare Cable Outer Jacket and Shield According to Type

    Remove the outer jacket to the specified dimension. Fold back shield wires. For flat metallic tape shields, remove the tape and secure with vinyl plastic tape. For fabric tape shields, remove the tape and install a tape retainer and tape marker. For longitudinally corrugated shields, remove the shield and install a tape marker. For semi-con shields, remove the shield and install a tape marker, ensuring not to cut or nick the cable insulation. If using UNISHIELD® or lead sheath cable, refer to the 10TL cable shield adapter instructions for preparation and grounding.

  4. Bevel Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Trim Insulation to Expose Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches (111mm) and 4-11/16 inches (119mm). If the length is outside this range, redo the assembly.

  6. Crimp Compression Lug onto Conductor

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the lug. Measure the 'Check Dimension' before crimping; it must be less than 6-1/2 inches (165mm). Crimp the lug according to its supplied instructions. Wipe off all excess inhibitor. After crimping, the distance from the end of the lug to the cable adapter should be 6-1/2 to 7-1/4 inches (165-184mm). Redo if dimensions are incorrect.

  7. Lubricate and Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance using the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Product and Install Stud

    WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.

  9. Connect Elbow to Mating Product Using Assembly Tool

    Push the elbow onto the mating part. For products dated October 1, 2013, or later, use the 600ATM assembly tool. Engage the hex broach in the contact assembly and insert it into the elbow interface to engage the stud. Tighten the contact assembly to 50-60 foot-pounds torque. DO NOT EXCEED 60 FOOT POUNDS TORQUE.

  10. Ground Cable Shield and Waterproof Jacket

    Insert one end of a wire, with ampacity at least equivalent to No. 14 AWG Copper, through the grounding eye and twist to form a small loop, avoiding damage to the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions for any grounding device used, or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  11. Install Mating Connector or Accessory

    Clean and lubricate the entire loadbreak interface and the DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions provided with those specific products.

  12. Verify Complete Seating of Assembly

    Confirm the complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side. This indicates full seating.

  13. Perform Voltage Test on 656CETP (If Applicable)

    If applicable for 656CETP, remove the test point cap with a hotstick by peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Use a suitable sensing device designed for capacitive test points. Do not use conventional voltage measuring equipment. Contamination or incorrect equipment can give false readings; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.