ABB - Installation Products 655CETP-K0300-DRG - 15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil. Includes Insulated cap

ABB Installation Products 655CETP-K0300-DRG 15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable…

UPC: 075114246354


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655CETP-K0300-DRG 15kV 600 Amp Dead Break Combo T Elbow Kit delivers a reliable, space-saving solution for medium-voltage cable terminations. Designed for 15kV systems, this kit supports phase-to-ground operating voltages up to 8.3kV and phase-to-phase voltages up to 14.4kV, with a basic impulse level (BIL) of 95kV and a 1-minute AC withstand rating of 34kV. The 200A loadbreak interface allows for safe, continuous operation at 200A with a 10kA symmetrical momentary rating over 10 cycles, while the 600A deadbreak connection supports 600A continuous current and 25kA symmetrical momentary ratings. This kit includes a 200A reducing tap plug, a 5/8"–11 stud, a cable adapter, and a universal aluminum compression lug compatible with compressed stranded conductors up to 350 kcmil or solid compact conductors up to 400 kcmil. The cable insulation diameter range is 1.090" to 1.310", ensuring broad compatibility with standard medium-voltage cables. The internal hex broach design ensures proper installation torque and reduces the risk of cross-threading, while the IEEE 386 color-coded PBT interface provides visual confirmation of proper seating and reduces sticking during installation. The hollow bore of the ComboT elbow allows for visual validation of the compression lug position before final assembly, simplifying installation and reducing errors. The kit is supplied without a test point, streamlining the installation process for applications where this feature is unnecessary. An insulated cap is included for enhanced safety during both installation and operation. The simplified connection system reduces stack height by 2.67" compared to traditional configurations, minimizing space requirements and inventory complexity. Assembly requires only standard tools, making it suitable for field installations and maintenance operations.
  • 15kV voltage class with 8.3kV phase-to-ground and 14.4kV phase-to-phase ratings
  • 600A deadbreak and 200A loadbreak interfaces with 25kA/10kA momentary ratings
  • Universal aluminum compression lug for 350 kcmil stranded or 400 kcmil solid compact conductors
  • Cable insulation diameter range: 1.090" to 1.310"
  • IEEE 386 color-coded PBT interface for visual seating confirmation and reduced sticking
  • Hollow bore design enables visual validation of lug positioning before final assembly
  • Internal hex broach ensures proper installation torque and reduces cross-threading risk
  • Includes insulated cap for enhanced safety during installation and operation
  • Reduces stack height by 2.67" compared to traditional configurations
  • Assembles with standard tools; no specialized equipment required

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Black
Conductor Range
350 kcmil , 400 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
655CETP
Size
1.090-1.310 inch (cable insulation diameter)
Special Features
Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS-G1 Jacket Seal and Grounding Kit Included.

K655LR-K0300-SG1

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS-G1 Jacket Seal and Grounding Kit Included.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug, No Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. With Insulated Cap

655CETP-J5300-DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug, No Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. With Insulated Cap
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap and Shrink-Fit Jacket Seal Kit

K656CETP-P0410-DRGS

15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap and Shrink-Fit Jacket Seal Kit
200 Amp LoadBreak Replacement Elbow without Test point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

167RLR-H-5260

200 Amp LoadBreak Replacement Elbow without Test point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
600 Amp, 15KV, Combo T Elbow Reducing Tap Plug with stud, cable adapter, Lug and Insulated Cap kit, No Test Point, Cable Insulation Diameter Range - 1.180 ti 1.465 inches, Connector Type - Universal Aluminum, Connector Size - AWG or Kcmil - Stranded Compressed 500, Solid/Compact 600, MMSQ Compact only 300.

655CETPL0330

600 Amp, 15KV, Combo T Elbow Reducing Tap Plug with stud, cable adapter, Lug and Insulated Cap kit, No Test Point, Cable Insulation Diameter Range - 1.180 ti 1.465 inches, Connector Type - Universal Aluminum, Connector Size - AWG or Kcmil - Stranded Compressed 500, Solid/Compact 600, MMSQ Compact only 300.
15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 kcmil or Solid/Compact 900 kcmil.

K655CETP-M0380

15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 kcmil or Solid/Compact 900 kcmil.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap

655CETP-J0270-DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap
15kv, 600 Amp (base aluminum) No Test Point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter Range - 1.180 to 1.465 inches (30.0 to 37.2 mm), Universal Aluminum Connector Type, Connector Sizing - 750 Stranded/Compressed, 900 Solid/Compact. No Sealing Kit.

655CETP-L0380

15kv, 600 Amp (base aluminum) No Test Point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter Range - 1.180 to 1.465 inches (30.0 to 37.2 mm), Universal Aluminum Connector Type, Connector Sizing - 750 Stranded/Compressed, 900 Solid/Compact. No Sealing Kit.

Frequently Asked Questions

What is a critical safety step before ComboT installation?

The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.

What is a critical safety step before ComboT installation?

The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.

What conductor sizes are compatible with ComboT connectors?

ComboT connectors are compatible with conductor sizes ranging from AWG 2 (25 mm2) up to 1250 kcmil (630 mm2).

What cable insulation diameter range does ComboT support?

ComboT supports a wide range of cable insulation diameters, from 0.42 inches to 1.935 inches.

How much does the ComboT reduce stack height?

Each combination elbow/connecting plug reduces the stack height by 2.67 inches.

What stud size is used for ComboT assembly?

ComboT connectors utilize a standard 5/8 in–11 stud that threads into the equipment bushing.

What is the continuous current rating for CCP and CBW connectors?

CCP and CBW connectors have continuous current ratings of 600 A or 900 A.

What are the voltage ratings for CCP and CBW connectors?

CCP and CBW connectors have a voltage class of 15/25/28 kV, with a max phase-to-ground operating voltage of 16.2 kV.

What is the continuous current rating for CETP connectors?

CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak interfaces. 900 A is also available for deadbreak.

What are the voltage ratings for CETP connectors?

CETP connectors are available in 15 kV and 25 kV voltage classes, with max phase-to-ground operating voltages of 8.3 kV or 15.2 kV.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 655/656/675/676CETP deadbreak elbow connectors, including cable preparation, lug crimping, and connection to mating apparatus. These connectors provide fully shielded, submersible deadfront cable connections for 15kV class systems.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductors), 600AT assembly tool (for products dated Sep 30, 2013 or earlier), 600ATM assembly tool (for products dated Oct 1, 2013 or later), Hotstick, Suitable sensing device (for voltage test)

Supplies needed:

655/656/675/676CETP Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Lubricant), Vinyl Plastic Tape, Tape Retainer (if using fabric tape shield), Tape Marker (if using fabric, corrugated, or semi-con shield), 10TL cable shield adapter (if using UNISHIELD® or lead sheath cable), No. 14 AWG Copper wire (or equivalent) for grounding, Suitable ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone grease (for test point cap)

  1. Perform Pre-Installation Checks and De-energize Apparatus

    DANGER: All apparatus must be de-energized during installation or removal of part(s). For loadbreak products, follow operating instructions. All deadbreak connectors must be de-energized before operating. All 200A deadbreak connectors must be mechanically secured with bails when connected. Inspect all parts for damage, proper rating, and compatibility with mating parts. Check the contents of the package to ensure they are complete and undamaged. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Connection

    Position the cable in its final assembled position, ensuring enough slack for adequate clearance to remove elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires.

  3. Prepare the Cable Jacket and Shield

    Remove the outer jacket to the dimension specified in the instructions (e.g., 12 3/4” (324mm)). Fold back the shield wires. If using flat metallic tape shield, remove it and secure with vinyl plastic tape to the specified dimension. If using fabric tape shield, remove it and install a tape retainer and tape marker to the specified dimensions. If using longitudinally corrugated shield, remove it and install a tape marker to the specified dimension. If using UNISHIELD® or lead sheath cable, a 10TL cable shield adapter is required; refer to its installation instructions for cable preparation and grounding. If using semi-con shield, remove it and install a tape marker to the specified dimensions, taking care not to cut or nick the cable insulation.

  4. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation using the supplied lubricant, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare the Conductor and Crimp the Compression Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to cut or nick the cable adapter or the conductor. Verify the exposed conductor length is 4 3/8”–4 11/16” (111mm–119mm); if not, redo the assembly. For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; it should be less than 6 1/2” (165mm). Crimp the compression lug following its supplied instructions. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is 6 1/2”–7 1/4” (165mm–184mm); if not, redo the assembly.

  6. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance using the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  7. Connect to Mating Product

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove any protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  8. Torque the Contact Assembly

    Push the elbow onto the mating part. If the product is dated September 30, 2013 or earlier, use the 600AT assembly tool, engage the hex broach in the contact assembly, insert it into the elbow interface to engage the stud, and torque until the torque limiter on the 600AT ratchets (19 to 25 foot/pounds torque). If the product is dated October 1, 2013 or later, use the 600ATM assembly tool, engage the hex broach in the contact assembly, insert it into the elbow interface to engage the stud, and tighten to 50/60 foot/pounds torque. DO NOT EXCEED 60 FOOT POUNDS TORQUE.

  9. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with any grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  10. Install Mating Connector (Optional Tap)

    Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant or ELASTIMOLD® approved lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with each of those products.

  11. Verify Seating and Perform Voltage Test (if applicable)

    Verify complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side. For 656CETP products equipped with an integral capacitance test point: Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points and follow its manufacturer’s directions. Treat the elbow as energized until the “no voltage” indication is confirmed by other means to prevent serious or fatal injury. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.