ABB Installation Products K656CETP-P0410-DRGS 15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug…
UPC: 075114261234
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25 kV voltage class with 600 Amp continuous current rating
- Non-corrosive capacitive test point for safe diagnostic testing
- Supports cable insulation diameters from 1.515" to 1.780" (38.5-45.2 mm)
- Aluminum compression lug for conductors up to 1000 kcmil
- Includes insulated cap and shrink-fit jacket seal kit for environmental protection
Specifications
Amperage Rating | 600 A |
Application | 600 Amps, 25kV Connector |
Color | Red |
Color | Black |
Conductor Range | 1000 kcmil |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | K656CETP |
Size | 1.515-1.780 inch (cable insulation diameter) |
Special Features | Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | ComboT Elbow with Test Point |
Voltage Rating | 25 kV |
Voltage Rating | 15/25 kV |
Width | 13.31 in |
Width | 338.074 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656CETPN0410
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
167RLR-H-5260
200 Amp LoadBreak Replacement Elbow without Test point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
655CETPL0330
600 Amp, 15KV, Combo T Elbow Reducing Tap Plug with stud, cable adapter, Lug and Insulated Cap kit, No Test Point, Cable Insulation Diameter Range - 1.180 ti 1.465 inches, Connector Type - Universal Aluminum, Connector Size - AWG or Kcmil - Stranded Compressed 500, Solid/Compact 600, MMSQ Compact only 300.
K655CETP-M0380
15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 kcmil or Solid/Compact 900 kcmil.
655CETP-J0270-DRG
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap
655CETP-L0380
15kv, 600 Amp (base aluminum) No Test Point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter Range - 1.180 to 1.465 inches (30.0 to 37.2 mm), Universal Aluminum Connector Type, Connector Sizing - 750 Stranded/Compressed, 900 Solid/Compact. No Sealing Kit.
655CETP-K0300S
15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil. Includes Cold-Shrinkable Jacket Seal.
K656CETP-N0410-DRG
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap.Frequently Asked Questions
How much does the ComboT reduce stack height?
Each combination elbow/connecting plug reduces the stack height by 2.67 inches.
What accessories are included with the K656CETP-P0410-DRGS kit?
The K656CETP-P0410-DRGS kit includes a stud, cable adapter, lug, insulated cap, and a shrink-fit jacket seal kit.
What cable insulation diameter does the K656CETP-P0410-DRGS support?
The K656CETP-P0410-DRGS supports a cable insulation diameter range of 1.725 to 1.935 inches.
What is the primary safety precaution for ComboT installation?
The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.
What stud size is used for ComboT assembly?
ComboT assembly utilizes a standard 5/8 in–11 stud that threads into the equipment bushing.
What is the continuous current rating for CCP/CBW connectors?
CCP and CBW connectors have continuous current ratings of 600 A or 900 A.
What is the maximum operating voltage for CCP/CBW connectors?
The maximum phase-to-ground operating voltage for CCP/CBW connectors is 16.2 kV, and phase-to-phase is 28.0 kV.
What is the loadbreak switching current for CETP?
The loadmake/loadbreak switching current for CETP connectors is 200 A.
What is the continuous current rating for CETP connectors?
CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak connections.
What is the maximum operating voltage for 25 kV CETP?
The maximum phase-to-ground operating voltage for 25 kV CETP is 15.2 kV, and phase-to-phase is 26.3 kV.
How to Install 655/656/675/676CETP Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 655/656/675/676CETP deadbreak elbow connectors, including cable preparation, lug crimping, and connection to mating products. DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area.
Tools needed:
Wire brush, 600AT assembly tool (for products dated Sep 30, 2013 or earlier), 600ATM assembly tool (for products dated Oct 1, 2013 or later), Hotstick, Suitable sensing device (for capacitive test points)
Supplies needed:
Elbow connector, Cable adapter, Compression lug, Lubricant, Vinyl plastic tape, Tape retainer (if fabric tape shield), Tape marker (if applicable for shield type), 10TL cable shield adapter (if using UNISHIELD® or lead sheath cable), Wire (at least No. 14 AWG Copper), Suitable connector (for grounding wire), HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone grease
- Position the Cable
Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.
- Clean the Cable Outer Surface
Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires.
- Address Grounding Device (If Applicable)
If a 20MA or 21MA grounding device or 600ECS Jacket Cable Seal is being used, refer to the installation instructions supplied with those specific products for cable outer jacket removal, shield connection, and grounding. Otherwise, proceed with the following instructions for cable preparation.
- Prepare the Cable Shield
Prepare the cable according to its specific shield type: remove the outer jacket to the specified dimension, fold back shield wires, and remove or secure tape shields as dimensioned. If using UNISHIELD® CABLE or lead sheath cable, a 10TL cable shield adapter is required; refer to its specific instructions for cable preparation and grounding. For semi-con shields, remove carefully to the specified dimensions without cutting or nicking the cable insulation.
- Install the Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation (using the supplied lubricant and working toward the semi-con shield). Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare the Conductor
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure not to cut or nick the cable adapter or the conductor. The exposed conductor length must be 4 3/8”–4 11/16” (111mm–119mm); otherwise, redo the assembly.
- Crimp the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the 'Check Dimension' (which must be less than 6 1/2” (165mm)) before crimping. Crimp the compression lug following its supplied crimping instructions. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6 1/2”–7 1/4” (165mm–184mm); otherwise, redo the assembly.
- Install the Elbow
Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker.
- Prepare Mating Products and Stud
DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring all surfaces remain clean.
- Connect Elbow to Mating Part
Push the elbow onto the mating part. Use the appropriate assembly tool (600AT for products dated September 30, 2013 or earlier, or 600ATM for products dated October 1, 2013 or later) to engage the hex broach in the contact assembly. Insert the contact assembly into the elbow interface to engage the stud. Torque the contact assembly until the torque limiter on the 600AT ratchets (19 to 25 foot/pounds) or tighten the 600ATM contact assembly to 50/60 foot/pounds torque. WARNING: DO NOT EXCEED 60 FOOT POUNDS TORQUE with the 600ATM tool.
- Ground the Cable Shield
Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow the instructions supplied with the grounding device, or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture entry.
- Install Additional Mating Connectors or Caps (If Applicable)
Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with each of these products.
- Verify Seating Indication
Confirm the complete assembly of an insulated cap or elbow by ensuring that no portion of the colored interface sleeve is visible when viewed from the side.
- Perform Voltage Test (656CETP Only)
If using a 656CETP connector, perform a voltage test. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for separable connectors with capacitive test points and follow its manufacturer’s directions. Contamination, moisture, dirt, or incorrect equipment can provide a false 'no voltage' indication; treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.