- 316 stainless steel construction resists corrosion from chlorides, chemicals, and moisture
- NEMA ratings 3, 3R, 4, 4X for dust, rain, splashing water, and corrosion protection
- Temperature range: 0°C to 150°C with high UV resistance for outdoor durability
- Duraplated ground cone ensures secure grounding and electrical continuity
- Dimensions: 1.64" (41.66mm) length, 1.14" (28.96mm) width for 3/8" conduit
Specifications
Application | Connects Flexible Metallic Liquidtight Conduit to a Box or Enclosure |
Color | Metallic |
Declaration of Conformity - CE | 9AKK107492A9907 |
Finish | None |
Insulation | True |
Material | 316 Stainless Steel with Duraplated Ground Cone |
NEMA Rating | 3;3R;4;4X |
Size | 3/8 Inch |
Special Features | Stronger and More UV-resistant than Nonmetallic Fittings |
Temperature Rating, Maximum | 302 F |
Temperature Rating, Maximum | 150 C |
Temperature Rating, Minimum | 302 F |
Temperature Rating, Minimum | 150 C |
Type | Straight Fitting for Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 6 IN x 4.5 IN x 4 IN |
Package Dimensions (L x W x H) | 15.24 cm x 11.43 cm x 10.16 cm |
Package Weight (Imperial) | 0.1200 L |
Package Weight (Metric) | 0.0540 kg |

5335SST6
1-1/4 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, UL/CSA Listed, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 2.60 Inches/66.04mm, Width 2.25 Inches/57.15mm, Temperature Range 0 to 105 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5337SST6
2 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, UL/CSA Listed, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 2.80 Inches/71.12mm, Width 3.05 Inches/77.47mm, Temperature Range 0 to 105 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5333SST6HT
3/4 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 1.75 Inches/44.45mm, Width 1.64 Inches/41.66mm, Temperature Range 0 to 150 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5334SST6HT
1 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 2.19 Inches/65.63mm, Width 1.87 Inches/47.50mm, Temperature Range 0 to 150 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5336SST6HT
1-1/2 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 2.68 Inches/68.07mm, Width 2.56 Inches/65.02mm, Temperature Range 0 to 150 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5337SST6HT
2 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 2.80 Inches/71.12mm, Width 3.05 Inches/77.47mm, Temperature Range 0 to 150 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5335SST6HT
1-1/4 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 2.60 Inches/66.04mm, Width 2.25 Inches/57.15mm, Temperature Range 0 to 150 Degrees C, 316 Stainless Steel with Duraplated Ground Cone
5332SST6HT
1/2 Inch Liquidtight Fitting for Flexible Metallic Conduit, Straight, High UV Resistance, NEMA Ratings: 3, 3R, 4, 4X, Length 1.74 Inches/44.20mm, Width 1.33 Inches/33.78mm, Temperature Range 0 to 150 Degrees C, 316 Stainless Steel with Duraplated Ground ConeFrequently Asked Questions
What material is the liquidtight sealing gasket made of?
The liquidtight sealing gasket has a 316 stainless steel ring for corrosion protection and is filled with TPE for higher temperature and chemical resistance.
When should an externally bonded fitting be used?
An externally bonded fitting is used when an external bonding jumper is required around liquidtight flexible metal conduit. It's for indoor and outdoor locations exposed to continuous or intermittent moisture.
What material is the new liquidtight fitting made from?
The new liquidtight fitting is manufactured from 316 stainless steel, offering superior corrosion resistance.
What is the maximum temperature rating for high-temperature fittings?
High-temperature fittings are designed for extreme temperatures up to 150° C.
What is the size range for steel liquidtight fittings?
Steel liquidtight fittings are available in sizes from 1/4" to 6" in straight, 45°, and 90° styles, with insulated and non-insulated options.
What is the size range for Steel Quick-Connect™ fittings?
Steel Quick-Connect™ fittings are available in sizes from 3/8" to 1" in straight, 45°, and 90° styles, with insulated and non-insulated options.
What is the size range for aluminum liquidtight fittings?
Aluminum liquidtight fittings are available in straight styles from 3/8" to 4" and in 90° styles from 3/8" to 2". They are non-insulated only.
What is the primary use of the steel liquidtight fitting?
Steel liquidtight fittings are used for liquid- and dust-tight connections between liquidtight flexible metal conduit and a box or an enclosure.
What is the size range for the new 316 stainless steel fittings?
The new 316 stainless steel fittings are available in sizes from 3/8" to 2" in straight, 45°, and 90° styles. They are insulated only.
When should an externally bonded fitting be used?
An externally bonded fitting is used when an external bonding jumper is required around liquidtight flexible metal conduit. It's for indoor and outdoor locations exposed to continuous or intermittent moisture.
How to Install the 5331SST6HT Liquid-Tight Flexible Metal Conduit Fitting
This guide provides step-by-step instructions for installing the 5331SST6HT stainless steel liquid-tight fitting onto flexible metallic conduit and securing it to an enclosure or box wall.
Estimated time: 15m
Tools needed:
Hacksaw, Standard screwdriver, Hammer, Torque wrench
Supplies needed:
5331SST6HT Liquid-Tight Fitting, Liquid-tight flexible metal conduit (LFMC), LNSS/038 Locknut (if using a knockout), 5261 Seal Gasket (if using a knockout)
- Prepare the Flexible Metal Conduit
Cut the end of the flexible conduit with a clean, square cut. Use a metal jig, a sharp hacksaw with 32 teeth/inch, or a power band saw (24-32 teeth/inch, not more than 400 ft/minute). DO NOT use an abrasive wheel.
- Assemble the Fitting Components onto the Conduit
Slide the gland nut onto the prepared end of the flexible metal conduit. Next, slide the nylon sealing ring onto the conduit, ensuring it is correctly oriented. Finally, thread the SAFE-EDGE® ground cone onto the conduit.
- Install the Fitting into the Enclosure
Insert the assembled fitting into the desired opening in the box wall or enclosure. For knockout applications, place the 5261 seal gasket (if required for liquid-tight seal) and then thread the LNSS/038 locknut onto the fitting from the inside of the enclosure.
- Secure the Locknut (for Knockout Applications)
If using a locknut for knockout applications, hand-tighten the LNSS/038 locknut and then further tighten it 1/4 turn using a hammer and a standard screwdriver, or an equivalent method. The recommended torque for the LNSS/038 locknut is 70 lb-in (7.9 N-m).
- Tighten the Gland Nut
Tighten the gland nut to the UL recommended value to ensure a liquid-tight seal. For the 5331SST6HT fitting (3/8" NPT), the recommended tightening torque for the gland nut is 235 lb-in (26.6 N-m).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.