ABB - Installation Products 274RLR-G-5220 - 25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products 274RLR-G-5220 25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation…

UPC: 783786367474


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 8

Multiplier: 8

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274RLR-G-5220 is a 25kV, 200 Amp loadbreak replacement elbow connector engineered for underground distribution systems. This bi-metal compression lug connector accommodates cable insulation diameters from 0.760 inch to 0.950 inch, making it compatible with a range of medium-voltage cables. The integrated test point enables safe voltage verification without de-energizing the system, reducing downtime during maintenance or fault detection. This connector features a compression-style termination for #2 AWG compressed stranded or #1 AWG solid conductors, with a cross-sectional area of 33.62 mm². The bi-metal construction ensures reliable electrical contact between aluminum conductors and copper components, minimizing corrosion risk in harsh environments. The loadbreak design allows for hot-stick operation, enabling safe connection and disconnection under load conditions up to 200 Amps. Ideal for repair of failed elbow connections where cables must be stripped back and a new compression lug applied, the 274RLR-G-5220 accommodates cables that are too short for standard elbows. It is also used to gain extra length when cables are accidentally trimmed or to convert equipment connections from live front to dead front without changing cable. The fully shielded, fully submersible molded rubber housing ensures dielectric strength and environmental resistance in outdoor or underground applications. The 100% peroxide-cured insulation, insert, and jacket deliver long-term reliability. The connector meets ANSI/IEEE Standard 386 for 25kV voltage class, with a maximum phase-to-ground operating voltage of 15.2kV, phase-to-phase voltage of 26.3kV, and 125kV BIL impulse withstand. It supports continuous and loadbreak operation at 200 Amps, with 10kA symmetrical momentary and fault close capability for 10 cycles.
  • 25kV, 200 Amp loadbreak replacement elbow connector
  • Bi-metal compression lug for #2 AWG compressed stranded or #1 AWG solid conductors (33.62 mm²)
  • Cable insulation diameter range: 0.760" to 0.950" (19.30 mm to 24.13 mm)
  • Integrated test point for safe voltage verification without de-energizing the system
  • Fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation
  • Hot-stick operation capability for safe connection/disconnection under load
  • Meets ANSI/IEEE Standard 386 for 25kV voltage class with 125kV BIL impulse withstand
  • Extended length housing and compression lug for repairing short cables or gaining extra length

Specifications

Amperage Rating
200 A
Application
25kV, 200 Amps
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Replacement Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.3000 L
Package Weight (Metric)
1.9510 kg
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.

K655LR-F5220

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
15-25 Kv Elbow Connector, 900 Amps, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

K675LR-N5380-SG3

15-25 Kv Elbow Connector, 900 Amps, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

755LR-N0400

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLR-G-5220

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

376LR-J5250-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

168ELR-88110-5260

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168RLR-H5240

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

755LR-N0330-S

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the current rating of the elbow connectors?

The elbow connectors are rated for 200 A loadbreak applications.

What voltage classes do these connectors support?

The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.

How much length does the repair elbow add?

The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.

How much length does the replacement elbow add?

The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.

What is the test point cap catalog number?

The test point cap catalog number for elbows with a test point is 156-7.

What material are the elbows constructed from?

The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.

Are these elbow connectors certified?

Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

Where are Elastimold elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.

Where are Elastimold 200 A elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.

What type of contact is included with the 274RLR?

The 274RLR includes a long bi-metal contact, catalog number 00400X.

How to Install the Elastimold 274RLR Loadbreak Replacement Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the Elastimold 274RLR Loadbreak Replacement Elbow Connector, converting livefront terminations to deadfront for UD cable.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Hotstick, Wire brush, Crimping tool, Wire strippers

Supplies needed:

Elbow connector housing, Compression lug, Probe, Lubricant (supplied), Hose clamp, No. 14 AWG / 2.5mm copper wire, Grounding connector, Silicone grease

  1. De-energize and Remove Livefront Termination

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Remove the rubber cap from the terminator. Cut off the existing connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  2. Prepare Cable for Connection

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. Carefully remove 1-3/8 inches of cable insulation from the end of the cable, ensuring to cut squarely and without nicking the conductor. If the insulation shield measures less than 6-1/2 inches from the end of the cut cable, proceed; otherwise, consult an Elastimold representative.

  3. Install and Crimp Compression Lug

    Wire brush the bare aluminum conductor immediately. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart (packaged with the compression lug) for recommended crimp information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  4. Lubricate and Assemble Elbow

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean of dirt and grime. Do not use excess grease or introduce any grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Connect Grounding and Neutral Wires

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown in the documentation and tighten it snugly, but do not overtighten.

  6. Connect Elbow to Bushing

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to ensure the internal lock engages. DO NOT OPERATE BY HAND.

  7. Verify Voltage Status (274RLR Only)

    For 274RLR models, perform a voltage test to establish if the circuit is energized. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used with capacitive test points. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false "no voltage" indication. To prevent serious or fatal injury, treat the elbow as energized until the "no voltage" test point indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.