ABB Installation Products 274RLR-G5240 25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .760 inch - .950…
UPC: 783786419555
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV, 200 Amp rated loadbreak elbow connector
- Supports .760" to .950" cable insulation diameter
- Compatible with 1/0 stranded or 2/0 solid copper wire
- Bi-metal compression lug for reliable electrical contact
- Integrated test point for safe voltage verification
Specifications
Amperage Rating | 200 A |
Application | 25kV, 200 Amps |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Special Features | Replacement Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector with Test Point |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 4.5100 L |
Package Weight (Metric) | 2.0460 kg |

252LR-C5240
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .805-1.060 inch Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
756LR-K0230
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50.
755LRTP-P0380-DRG
600 Amp, 35KV, Stick Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
755LRTP-N0380-DRG
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
755LRTP-J0240-DRG
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
755LR-P0400-SG3
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. 200ECS-G3 Jacket Seal and Grounding Kit Included.
273RLR-K-5270
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
755LR-P0360-SG3
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What is the test point cap catalog number?
The catalog number for the test point cap is 156-7.
Can these elbows be ordered with a jacket seal?
Yes, they are also available with a 200ECS jacket seal included. Add an "-S" suffix to the catalog number for this option.
Where are Elastimold 200 A elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.
What industry standards do these elbows meet?
These elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What material are the elbow connectors made from?
The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
Are these elbows available with a test point?
Yes, both repair and replacement elbows are available with an optional built-in capacitive test point to allow testing for the presence of voltage.
What is the extended length of the replacement elbow?
The replacement elbow provides a net gain of 8 7⁄8 inches in length compared to a standard elbow.
What is the extended length of the repair elbow?
The repair elbow provides a net gain of 3 1⁄4 inches in length compared to a standard elbow.
What is the current rating of these connectors?
These loadbreak repair and replacement elbow connectors are rated for 200 Amps.
What voltage classes do these elbows support?
The ABB Elastimold loadbreak repair and replacement elbows support 15 kV and 25 kV voltage classes.
How to Install the 273RLR/274RLR Loadbreak Replacement Elbow Connector
This guide provides step-by-step instructions for the safe installation and assembly of the 273RLR and 274RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cables.
Estimated time: 1h
Tools needed:
Probe Wrench, Wire brush, Hotstick
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for grounding)
- Perform Pre-Installation Checks
Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; if encountered, replace damaged components. Read all instructions and gather required tools, maintaining cleanliness throughout the procedure.
- De-energize Apparatus and Remove Livefront Terminator
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Remove the rubber cap from the terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Remove the terminator housing from the cable.
- Prepare the Cable
Train cables to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. Remove 1-3/8 inches of cable insulation from the end, cutting squarely. DO NOT NICK THE CONDUCTOR. If the insulation shield measures less than 6-1/2 inches, proceed; if greater, consult an ELASTIMOLD representative.
- Install Compression Lug
Wire brush the bare aluminum conductor and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Assemble Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants. Keep insulation clean and avoid introducing excess grease into the gap between the lug and insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole.
- Thread and Tighten Probe
Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect Concentric Neutral
Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires and connect them to ground using an appropriate connector, providing adequate slack for elbow operation. Add the hose clamp as shown and tighten snugly, but do not overtighten.
- Lubricate and Connect Elbow to Bushing
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle over the bushing plug, inserting the elbow male contact until slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.