ABB - Installation Products 35PCJ1P1380-S - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 35PCJ1P1380-S 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786081523


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 35PCJ1P1380-S is a 35kV power cable joint engineered for medium-voltage cable systems requiring permanent, fully shielded, and fully submersible straight splices. This joint is rated per IEEE Standard 404 and designed for 35kV voltage class with a 200kV BIL impulse withstand (1.2 x 50 microsecond wave), 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. It accommodates cable insulation diameters between 1.725 inches and 1.935 inches, making it suitable for 750 AWG stranded aluminum conductors in industrial, utility, and infrastructure applications. The single-piece housing simplifies installation by eliminating multi-part assembly steps, reducing labor time and potential error points. The cold-shrinkable jacket seal ensures a watertight, corrosion-resistant interface without the need for heat-shrink tools or torches, improving safety and consistency in field conditions. The molded conductive shield provides a virtually indestructible ground shield for true deadfront construction, while the grounding eye offers a convenient point to connect a ground wire to the molded conductive shield, placing it at ground potential. This joint withstands pulls of up to 500 lbs and is designed for continuous current ratings equal to that of the cable rating, with a short-time current rating up to 35kA. It meets ANSI C119.4 Class A and Class 3 connector ratings and is suitable for use in power distribution networks, renewable energy substations, and heavy industrial facilities where medium-voltage cable joints must withstand environmental stress and maintain dielectric integrity. The joint can be installed either directly buried or in a vault, and operates equally well on UD cable with concentric neutral and extruded insulation shielding, as well as fabric tape shielded or lead-jacketed cables when used with the proper Elastimold® cable shield adapter or grounding device.
  • Rated for 35kV voltage class per IEEE Standard 404
  • Accommodates cable insulation diameters 1.725" to 1.935"
  • Designed for 750 AWG stranded aluminum conductors
  • Single-piece housing simplifies installation and reduces labor time
  • Cold-shrinkable jacket seal ensures watertight, corrosion-resistant interface

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
750 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
15-3/4 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.

35PCJ1N1380-S

35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 500.

15PCJ1J2330

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ2L1300-J1270

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1H2250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2M1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

15PCJ2L1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1H1250-1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2L1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

Frequently Asked Questions

What are the available voltage classes?

The PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the maximum pull force the interlock withstands?

The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force up to 500 lb.

What is the purpose of the grounding eye?

The grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing the molded shield at ground potential.

How is a catalog number constructed for transition joints?

When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.

Can copper connectors be used on aluminum conductors?

No, copper connectors should not be used on aluminum conductors. An all-copper connector is only suitable for copper-to-copper connections.

What standards do the PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What is the short-time current rating?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating?

The continuous current rating of the PCJ power cable joints is equal to that of the cable rating.

What environments are suitable for installation?

PCJ power cable joints can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, fully submersible splice.

What are the two styles of PCJ joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for aluminum to aluminum and/or aluminum to copper conductors.

Estimated time: 2h

Tools needed:

Wire-brush, Crimping tool, Cable cutting and stripping tools, Measuring tape or ruler, T&B WT3D tool (for 35kV installations)

Supplies needed:

15/25/35PCJ1 Series Joint Kit (includes Housing, Splice, Lubricant), Appropriate connector for grounding wires, DELTEC Cable ties (TYD5135) (for 35kV installations), #14 AWG copper wire or equivalent (if needed for grounding), Cable jacket reconstruction material (if applicable)

  1. De-energize Apparatus and Inspect Components

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical equipment. Verify that all apparatus in the work area is de-energized. Inspect all components of the joint housing, splice, and lubricant for completeness, damage, proper rating, and compatibility with the cables and mating products. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if applicable.

  2. Prepare Cable Ends for Splicing

    Overlap both cables and cut them to 12 inches (305mm) from the intended center line of the joint. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Finally, cut both cables precisely at the center line of the joint.

  3. Prepare Cable 1 and Position Joint Housing

    Taper the edge of Cable 1's insulation at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it back up to the shield wires for temporary storage.

  4. Remove Cable Insulation and Shield for Splice Area

    Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the 'Y' dimension in the provided table (e.g., 6 1/4 inches for 500-750 MCM). Then, carefully remove the insulation shield from both cables according to the 'X' dimension (e.g., 2 1/2 inches for 500-750 MCM). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.

  5. Install and Crimp the Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the dimension between the cable insulations does not exceed the 'Max Check Before' dimension (e.g., 6 inches for 500-750 MCM); if it does, redo the assembly. Crimp the splice securely following the manufacturer's recommendations. Wipe off any excess inhibitor. After crimping, re-check the distance between cable insulations against the 'Max Check After' dimension (e.g., 6 1/4 inches for 500-750 MCM); if exceeded, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area.

  6. Lubricate Cables and Slide Housing into Final Position

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield. Carefully slide the joint housing from its stored position on Cable 1 into its final central position over the splice. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  7. Complete Grounding and Jacket Reconstruction

    For 35kV installations ONLY, install two DELTEC Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch from the splice edge, with the second tie 1/4 inch from the first and locking heads offset. Use a T&B WT3D tool to tighten and trim. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.