ABB - Installation Products 35PCJ1N1380-S - 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.

ABB Installation Products 35PCJ1N1380-S 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch.…

UPC: 783786338467


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1N1380-S is a 35kV power cable joint engineered for medium-voltage distribution systems requiring permanent, fully shielded splices. This joint accommodates cable insulation diameters between 1.515 and 1.780 inches, making it suitable for compressed stranded conductors sized 700/750 kcmil or compacted solid conductors up to 900 kcmil. The aluminum compression lug ensures low-resistance electrical connections, critical for maintaining system efficiency and minimizing heat generation in high-current applications. Rated per IEEE Standard 404, the 35PCJ1N1380-S delivers a 200kV BIL impulse withstand (1.2 x 50 microsecond wave), 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. Its continuous current rating matches the connected cable, with a short-time current rating up to 35kA. The molded conductive shield provides a virtually indestructible ground shield for true deadfront construction, while the fully submersible molded rubber housing ensures reliable performance in direct burial or vault installations. Key features include: - Pin and socket interlock design withstanding pulls up to 500 lbs - Grounding eye for convenient shield grounding - Cable entrance engages insulation shielding, eliminating taping requirements - Cold shrinkable jacket seal for simplified installation and consistent watertight performance - Compatible with UD cable having concentric neutral and extruded insulation shielding, as well as fabric tape shielded or lead-jacketed cables with proper adapters Applications include utility substation terminations, industrial facility power feeds, commercial building electrical rooms, renewable energy interconnections, and critical infrastructure protection. The joint is designed for underground and aerial medium-voltage circuits, offering durability against moisture, UV exposure, and mechanical stress. For specifiers and contractors, this product delivers a balance of performance and ease of installation with materials selected for long-term reliability.
  • 35kV rated per IEEE Standard 404 with 200kV BIL impulse withstand
  • Accommodates 1.515-1.780" insulation diameter for 700/750 kcmil stranded or 900 kcmil solid conductors
  • Aluminum compression lug ensures low-resistance electrical connections
  • Cold shrinkable jacket seal simplifies installation and ensures watertight performance
  • Fully shielded, submersible design withstands 500 lbs pull force

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
750 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
15-3/4 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cold-Shrinkable Jacket Seal Included.

35PCJ1P1380-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cold-Shrinkable Jacket Seal Included.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 1000.

25PCJ1P2410

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 1000.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

35PCJ1N1380

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

25PCJ2H1240-F1220

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Z - Thin Walled, Connector

25PCJ1N1410Z

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Z - Thin Walled, Connector
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.

25PCJ1N2380

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.
25 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.

25PCJ1M1400

25 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

25PCJ1M1380

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

Frequently Asked Questions

What standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What environments are PCJ joints suitable for?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice. They can be installed in direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

Can copper connectors be used on aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only. They should not be used on aluminum conductors.

What are the available voltage classes?

The Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What types of conductors can be spliced?

These joints can splice copper or aluminum conductors up to 1250 kcmil. They are designed for UD cable with concentric neutral and extruded insulation shielding.

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

Can copper connectors be used on aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only. They should not be used on aluminum conductors.

What standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

How to Install the 15/25/35PCJ1 Series Cable Joint

This guide provides detailed instructions for installing the 15/25/35PCJ1 series permanent, fully shielded, and submersible cable joint for aluminum or copper conductors. Ensure all safety precautions are followed for high voltage electrical equipment.

Estimated time: 2h

Tools needed:

Wire strippers, Knife or tapering tool, Wire brush, Crimping tool, Deburring tool, Measuring tape or ruler

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Cable 1, Cable 2, #14 AWG copper wire or equivalent (if needed), Appropriate connector for shield wires, Jacket sealing or restoration kits (if applicable), Cleaning supplies, Inhibitor (where applicable)

  1. De-energize and Prepare Cables

    DANGER: De-energize all apparatus before beginning installation. Ensure all local and national work rules are followed. Inspect all parts for damage, rating, and compatibility. Gather all required tools and supplies, and maintain cleanliness. Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline. Remove the cable jacket of Cable 1 to 34 inches (865mm) and Cable 2 to 20 inches (510mm), if applicable. Fold back the shield wires on both cables. Cut both cables at the joint's centerline.

  2. Prepare Cable Insulation and Store Housing

    Taper the edge of Cable 1's insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires, ensuring electrical interfaces are not contaminated. Carefully remove the cable insulation and then the insulation shield from both cables using the provided stripping guide. WARNING: Do not cut or nick the cable insulation or conductor, as this can lead to assembly failure.

  3. Install and Crimp the Splice

    If using aluminum conductors, wirebrush them thoroughly and immediately insert them into the splice. Crimp the splice according to the manufacturer's recommendations. Wipe off any excess inhibitor (if applicable). Verify the 'Check' dimension does not exceed 5 inches (127mm) and the distance between cable insulations does not exceed 5-1/4 inches (133mm); redo the assembly if these dimensions are exceeded. Remove any sharp protrusions or burrs from the crimped splice. Ensure all metal chips/filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate them in the direction of the arrows to create a lubricant build-up at the edge of the insulation shield.

  4. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. Reshape the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Reconstruct the cable jacket (if applicable) over both cables and the joint housing.

  5. Seal the Cable Jacket (If Applicable)

    WARNING: If one or both cables are jacketed, it is critical to seal the ends of the jacket or completely restore the jacket across the joint. Follow standard operating procedures or instructions provided with compatible jacket sealing or restoration kits to ensure appropriate seals or restoration.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.