Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2L1330 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

ABB Installation Products 15PCJ2L1330 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786271795


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15kV Power Cable Joint (SKU: 15PCJ2L1330) is a Style 2 joint designed for medium-voltage power cable installations. This joint features a universal housing and separate cable adapters, enabling compatibility with cable insulation diameters ranging from 1.180 inch to 1.465 inch. The joint accommodates 500 AWG stranded aluminum conductors, making it suitable for heavy-duty power distribution systems. This joint is engineered for 15kV class applications, ensuring reliable electrical continuity and mechanical strength in underground or aerial installations. The universal housing design simplifies installation by accommodating variations in cable insulation without requiring custom fabrication. Separate cable adapters allow for precise fitment to specific cable types, reducing installation time and potential errors. Typical applications include utility power distribution, industrial facilities, commercial buildings, and renewable energy projects where medium-voltage cable joints are required. The joint’s design supports long-term reliability under standard operating conditions, including thermal cycling and mechanical stress. Key specifications: - Voltage class: 15kV - Conductor size: 500 AWG stranded aluminum - Insulation diameter range: 1.180 inch to 1.465 inch - Housing type: Universal with separate adapters - Manufacturer: ABB - Installation Products
  • 15kV rated medium-voltage cable joint
  • Universal housing with separate cable adapters
  • Accommodates 500 AWG stranded aluminum conductors
  • Insulation diameter range: 1.180" to 1.465"
  • Compatible with standard medium-voltage cable systems

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
21 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.

15PCJ2J1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1H1250-1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2L1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

25PCJ1LM1310

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1H1260-1240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch.

35PCJ1K

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2N1410-P1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1R242PVDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Frequently Asked Questions

What type of connector is included for aluminum conductors?

Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil. They provide a permanent, fully shielded, fully submersible splice.

What types of installations are supported?

PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor types and sizes are compatible?

They are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What pull force can the interlock withstand?

The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force up to 500 lb.

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the continuous current rating?

The continuous current rating of the PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

How to Install the 15/25/35PCJ2W Cable Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ2W series straight joint for aluminum and/or copper conductor, wire shielded cables. Ensure all apparatus is de-energized before beginning.

Estimated time: 2h

Tools needed:

Wire strippers, Circular cutting tool, Glass scraper, Wirebrush, Hex wrench, Crimping tool

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars, Hose Clamp, Electrical tape, #14 AWG copper wire (or equivalent), Appropriate connector (user supplied), Heat/cold shrink jacket (user supplied)

  1. Perform Safety Checks and Initial Preparation

    DANGER: Ensure all apparatus is de-energized before installation or removal. Inspect all components for damage, rating, and compatibility. Examine mating cable ends for moisture and contaminants. Remove graphite coatings 12 inches (30.5cm) beyond the cable jacket cut using a circular cutting tool or glass scraper; avoid sanding. If conductors contain strand filled or water-blocking material, contact the cable manufacturer for welding/crimping procedures.

  2. Prepare Cable Jackets and Position Housing

    Using a stripping guide, carefully remove the cable jacket of both cables for a distance of 11-1/4 inches (285.7mm). Fold back the shield wires and tape the end of the wires on Cable 1, allowing enough extra length to rejoin later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm).

  3. Prepare Cable Insulation

    Using the stripping guide, carefully remove the insulation shield and cable insulation. CAUTION: DO NOT CUT OR NICK THE INSULATION, as this could lead to assembly failure. Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield on both cables to serve as a marker. Clean the cable insulation thoroughly, then lubricate it to create a build-up or ramp of lubricant at the edge of the insulation shield.

  4. Install Cable Adapters and Retaining Collars

    Lubricate the inside of both ends of one cable adapter. Install this cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the other cable adapter on Cable 2. Select the retaining collars and partially thread the proper size setscrews. Position each retaining collar over the insulation, flush against its respective cable adapter. Using the supplied hex wrench, tighten each set screw one or two turns at a time to keep the collar centered, then continue tightening until the screws are below the collar surface.

  5. Splice Conductors

    Thoroughly clean the ends of the cable adapters and the cable where shown. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored to hold the adapter in place. Tape over the hose clamp to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Verify the 'Check' dimension does not exceed 8-1/2 inches (215mm); redo assembly if it does. Crimp the splice according to its recommendations. Wipe off all excess inhibitor. Check the distance between cable adapters; redo assembly if it exceeds 8-3/4 inches (222mm). Clean and lubricate the outside surface of the cable adapters.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, centering it over the cable adapters. Remove all tape, ensuring that no cable or adapter insulation is exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and over the joint housing using heat/cold shrink materials (not included).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.