Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1J1230S - 35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Jacket Seal included.

ABB Installation Products 35PCJ1J1230S 35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch.…

UPC: 075114170758


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35kV Power Cable Joint Style 1 (SKU: 35PCJ1J1230S) is engineered for reliable and secure termination of high-voltage power cables. Designed for a voltage rating of 35 kV, this joint is suitable for cable insulation diameters ranging from 0.980 inches to 1.180 inches. The integrated aluminum compression lug ensures a robust and low-resistance connection for conductors sized for AWG or kcmil, specifically accommodating compressed stranded #1/0 or compacted solid 1/0 conductors, equivalent to 50 mm² compact. This Style 1 joint from ABB Installation Products features a cold shrinkable jacket seal, providing a durable and weather-resistant seal that protects the splice from environmental ingress. The cold shrink technology simplifies installation, eliminating the need for heat or open flames, which is critical in many industrial and utility applications. Its construction with high-quality aluminum for the compression lug guarantees excellent conductivity and long-term performance under demanding electrical loads. This product is essential for maintaining the integrity and safety of medium-voltage power distribution systems, ensuring uninterrupted power flow. The precise sizing and material specifications make it a dependable choice for utility companies, industrial facilities, and infrastructure projects requiring high-voltage cable splicing solutions. Its robust design and ease of application contribute to reduced installation time and enhanced operational reliability. The UNSPSC code for this product is 39121452, categorizing it within electrical connectors and accessories.
  • 35 kV Voltage Rating for high-voltage applications
  • Accommodates cable insulation diameters from 0.980 to 1.180 inches
  • Aluminum compression lug for reliable conductor connection
  • Suitable for AWG/kcmil conductors (#1/0 stranded or solid, 50 mm² compact)
  • Includes cold shrinkable jacket seal for environmental protection

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#1 STR AWG , 1/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ2J1230

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ2F2240

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2H1250-H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ2K2300-J2270

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ2F1210

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size kcmil Stranded-Compressed 250, Solid-Compact 300.

25PCJ1-K1280

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size kcmil Stranded-Compressed 250, Solid-Compact 300.
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter

69TCJS1R246PVDHNN

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ2F1240

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

Frequently Asked Questions

What is the voltage rating of this cable joint?

The voltage rating of this ABB Power Cable Joint Style 1 is 35 kV.

What cable insulation diameters does this joint support?

This joint supports cable insulation diameters ranging from 0.980 inches to 1.180 inches.

What type of lug is included with this cable joint?

This cable joint includes an aluminum compression lug for conductor connection.

What conductor sizes are compatible with this joint?

It is compatible with AWG or kcmil conductors, including compressed stranded #1/0, compacted solid 1/0, or 50 mm² compact.

Does this joint include a jacket seal?

Yes, this joint includes a cold shrinkable jacket seal for environmental protection.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides detailed instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible joint for connecting aluminum or copper conductor, wire shielded cables. Ensure all safety precautions are followed for high voltage electrical equipment.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush, Measuring tape or ruler, Knife or tapering tool, Cleaning cloths or wipes

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector for grounding wires, #14 AWG copper wire or equivalent (if needed), Jacket sealing or restoration kits (if applicable), Aluminum and/or copper conductor, wire shielded cables

  1. Prepare Cables for Joint Assembly

    DANGER: Ensure all apparatus is de-energized before beginning installation. Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Where applicable, remove the cable jacket of Cable 1 to 34 inches (865mm) and Cable 2 to 20 inches (510mm). Fold back the shield wires, then cut both cables precisely at the joint centerline.

  2. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and then lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, positioning it up to the shield wires.

  3. Prepare Cables for Splice Installation

    Using the provided stripping guide, carefully remove the cable insulation and then the insulation shield from both cables. WARNING: Do not cut or nick the cable insulation or conductor, as this could result in the failure of the assembly.

  4. Install and Crimp the Splice

    If using aluminum conductors, wirebrush them thoroughly and immediately insert them into the splice. Ensure the 'Check' dimension does not exceed 5 inches (127mm); if it does, redo the assembly. Crimp the splice following the recommendations provided with it. Wipe off any excess inhibitor. Verify that the distance between the cable insulations does not exceed 5-1/4 inches (133mm); if it does, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips or filings are removed from the splice and joint assembly area. Clean and lubricate the cables where indicated, applying lubricant in the direction of the arrows to create a build-up or ramp at the edge of the insulation shield.

  5. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position. Proper positioning is ensured by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. Reshape the shield wires and secure them to the ends of the joint as shown in the documentation. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector.

  6. Restore Cable Jacket (if applicable)

    WARNING: If one or both of the cables being joined are jacketed, it is critical to seal the ends of the jacket or completely restore the jacket across the joint. Follow standard operating procedures or instructions provided with compatible jacket sealing or restoration kits to ensure appropriate jacket seals or restoration.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.