Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274J2(1) - 200 Amp, 25kV, Loadbreak 2 Point Junction. Revision 1.

ABB Installation Products 274J2(1) 200 Amp, 25kV, Loadbreak 2 Point Junction. Revision 1.

UPC: 783786331376


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274J2(1) is a 200 Amp, 25kV Loadbreak 2 Point Junction designed for medium-voltage electrical distribution systems. This junction provides reliable loadbreak capability, enabling safe connection and disconnection of circuits under load without interrupting service. With a 25kV rating, it is suitable for applications in utility substations, industrial power distribution, and commercial electrical infrastructure. The 2-point design allows for efficient branching of electrical circuits while maintaining operational continuity. This product is Revision 1, ensuring compliance with current industry standards. The junction is engineered for durability and long-term performance in demanding electrical environments.
  • 200 Amp continuous current rating
  • 25kV rated voltage for medium-voltage applications
  • Loadbreak capability for safe circuit connection/disconnection
  • 2-point junction design for efficient branching
  • Revision 1 compliant with current industry standards

Specifications

Amperage Rating
200 A
Application
Designed for subsurface, vault or padmount applications and can be used for sectionalizing, looping, tapping, and equipment bypass
Color
Black
Insulation
True
Length
19 in
Length
482.6 mm
Material
EPDM-Rubber, Stainless Steel Mounting Hardware
Special Features
25kV, 200 Amp Loadbreak 2-Way Junction. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provides mating for other Elastimold loadbreak type products. Provides mating for Elastimold Elbow connectors. Mounting hardware for flat or curved mounting positions
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak 2-Way Junction
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
12.0000 L
Package Weight (Metric)
5.4430 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-H0240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
Copper Flood-Seal Street and Highway Lighting Compression Fuse and Disconnect Kits - YY-Type, fused, conductor size main 1/0, tap 14-6

YFC 1/0

Copper Flood-Seal Street and Highway Lighting Compression Fuse and Disconnect Kits - YY-Type, fused, conductor size main 1/0, tap 14-6
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, fused, conductor range stranded 1/0-2, and solid 2-14

SLK 102 M

Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, fused, conductor range stranded 1/0-2, and solid 2-14
Copper Flood-Seal Street and Highway Lighting Compression Non-Fused Kits - In-Line, Single Housing, wire size stranded 4 and solid 2

SDK 2

Copper Flood-Seal Street and Highway Lighting Compression Non-Fused Kits - In-Line, Single Housing, wire size stranded 4 and solid 2
Aluminum Insulated Y-Type Mechanical Streetlight Connector - Three Conductor, Wire Range #14-2/0 CU-AL, 1-27/32 inch x 3/4 inch x 9/16 inch with (3) 7/16-20 UNF-2B Holes on one side that intersects with (3) 31/64 inch Diameter through holes, includes Gray PVC Boot with dimensions 1-29/32 inch x 2-5/8 inch x 1-1/32 inch and Lubricant.

BY 320 C

Aluminum Insulated Y-Type Mechanical Streetlight Connector - Three Conductor, Wire Range #14-2/0 CU-AL, 1-27/32 inch x 3/4 inch x 9/16 inch with (3) 7/16-20 UNF-2B Holes on one side that intersects with (3) 31/64 inch Diameter through holes, includes Gray PVC Boot with dimensions 1-29/32 inch x 2-5/8 inch x 1-1/32 inch and Lubricant.
Copper Flood-Seal Street and Highway Lighting Compression Non-Fused Kits - In-Line, Twin Housing, wire size stranded 2

SDT 2

Copper Flood-Seal Street and Highway Lighting Compression Non-Fused Kits - In-Line, Twin Housing, wire size stranded 2
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, non-fused, wire size stranded 4, copper run, copper tap fused, installing dies 5/16,8,TP,29

DYC 4

Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, non-fused, wire size stranded 4, copper run, copper tap fused, installing dies 5/16,8,TP,29
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, non-fused, wire size stranded 1 copper run ,copper tap fused, installing dies 3/8,11K,TB,37

DYC 1

Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, non-fused, wire size stranded 1 copper run ,copper tap fused, installing dies 3/8,11K,TB,37

Frequently Asked Questions

What is the voltage rating of this junction?

The device has a 25kV voltage rating for medium-voltage applications.

What is the current rating of the ABB 274J2(1)?

The junction supports a continuous current rating of 200 Amps.

Does this junction support loadbreak operation?

Yes, the 274J2(1) is designed for loadbreak capability, allowing safe connection and disconnection under load.

Is the ABB 274J2(1) Revision 1 compliant?

Yes, this product is Revision 1, ensuring compliance with current industry standards.

How to Install 274J2(1), 274J3(1), or 274J4(1) Loadbreak Junctions

This guide provides step-by-step instructions for the universal mounting and initial setup of Elastimold 25kV class two-, three-, or four-point loadbreak junctions on flat or curved surfaces. The mounting angle is adjustable from 0° to 90°.

Estimated time: 45m

Tools needed:

Screwdriver, Wrench, Wire strippers, Marker or Pencil, Cleaning cloth

Supplies needed:

274J2(1), 274J3(1), or 274J4(1) Loadbreak Junction, Mounting brackets with hardware (included), Lubricant (included), Mounting bolts (user supplied, 17/32 inch / 13mm diameter), Grounding wire (No. 10 Solid to No. 1 Stranded), Elastimold 273DR insulated caps (for unused interfaces)

  1. Perform Initial Safety Checks and Inspect Components

    DANGER: All apparatus must be de-energized during installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all package contents and components for completeness, damage, rating, and compatibility with mating parts.

  2. Prepare and Mark Mounting Bracket Locations

    Loosely attach the universal mounting brackets to the junction back plate. Position the assembly against the desired wall surface (flat or curved), adjust the brackets for proper alignment, and mark their location on the wall.

  3. Mount Brackets to Wall

    Detach the universal mounting brackets from the junction back plate. Mount the brackets securely to the wall using user-supplied bolts (17/32 inch or 13mm diameter) according to the marks made in the previous step. Note that brackets can be inverted to adjust bolt center distance.

  4. Fasten Junction Assembly to Brackets

    Fasten the junction back plate (with the junction attached) to the securely mounted universal brackets. Ensure that the parking stands are in the upright position.

  5. Adjust and Secure Mounting Angle

    Adjust the junction's mounting angle to the desired position (0° through 90° above or below horizontal in 15° increments). Once positioned, securely tighten all bolts to prevent any movement during operation.

  6. Ground the Back Plate

    Ground the back plate using the provided grounding lug. Connect a grounding wire (No. 10 Solid to No. 1 Stranded) to the lug and ensure a secure connection to an appropriate ground.

  7. Prepare Bushing Interface and Install Mating Products

    Thoroughly wipe the bushing interface clean of any contaminants. Apply the supplied lubricant to the cleaned bushing interface. Install the mating products (e.g., elbow connectors) to the bushing insert, following the instructions provided with those mating products.

  8. Verify Seating and Secure Unused Interfaces

    Verify the complete assembly of any installed insulated caps or elbow connectors by ensuring no portion of the yellow band is visible when viewed from the side. WARNING: If any operating interfaces are not utilized, install an Elastimold 273DR insulated cap on each unused interface before energization. Do NOT use protective shipping covers for this purpose as they are not insulated.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.