Overview
- Non-fused mechanical fuse and disconnect kit for street/highway lighting
- Y-Type design with crimped lug connectors for 4 AWG stranded copper wire
- Flood-Seal construction for environmental protection against moisture/contaminants
- Compatible with 5/16" installing dies and TP-29 tooling
- Copper run and tap configuration for reliable circuit branching
Specifications
Amperage Rating | 30 A |
Application | Rated 600V, 30 Amps Maximum, perfect for heavy-duty applications |
Color | Black |
Conductor Range | #4 Copper AWG |
Connection | Compression |
Environmental Conditions | WaterTight |
Insulation | True |
Length | 9-3/4 in |
Material | Copper Connector, EPDM-Rubber Housing |
Number of Conductors | 3 |
Special Features | EPDM Flood-Seal Housing ensures a fully insulated, watertight, and submersible connection. Safe separations to ensure fuse or connecting link stays in load side when separated. Dual-Rated. Approved for a wide range of aluminum or copper connections |
Type | Break-Away Streetlight Kits |
Voltage Rating | 600V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.5500 L |
Package Weight (Metric) | 0.2500 kg |

FYA 4
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 4, aluminum run copper tap fused, installing dies 52,BG,243,5/8
VFN-021-00
Solenoid Valve Connectors, Field Wireable, 3 Pole, Form A 18mm, 250V, 10A, PG11 opening, gray housing
SDT-M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits-In-Line, non-fused, twin housing ,conductor range stranded 12,10,8,6,4 and solid 12,10,8,6,4
FYC 4
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 4, copper run, copper tap fused, installing dies 5/16,8,TP,29
FYC 6
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 6 ,copper run, copper tap fused, installing dies J,7,TE,24
FYC 8
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 8 ,aluminum run copper tap fused, installing dies 1/4,6,TC,21
URS 125 CSN
Compression Lugs Crimped Onto Insulated Wire With Rockets/caps. Includes (2) Lugs with 1-Hole Pad 1/2-12 UNC-2B, (2) Insulating Caps without Liners, (2) Insulating Rockets, (2) Screws 1/2-13 x 1 inch long, and 15 inches of 350 kcmil Aluminum Wire.Frequently Asked Questions
Is the DYC 4 kit fused or non-fused?
The DYC 4 is a non-fused mechanical fuse and disconnect kit.
What wire sizes does the DYC 4 support?
The kit supports 4 AWG stranded copper wire for both run and tap conductors.
What tooling is required for installation?
The kit requires 5/16" installing dies and TP-29 tooling for proper crimping.
What type of connectors does the DYC 4 include?
The kit includes crimped lug connectors for stranded copper wire terminations.
Where is the DYC 4 Flood-Seal kit used?
This kit is designed for street and highway lighting applications in outdoor environments.
How to Install the DYC/FYC Street Lighting Kit
This guide provides step-by-step instructions for the proper assembly and installation of the DYC/FYC Y-Type street lighting kit, including cable preparation and component connection. Ensure power is disconnected before beginning installation.
Estimated time: 1h
Tools needed:
Caliper, Wire strippers, Crimping tool, Wood dowel, Wire brush
Supplies needed:
Y-Type housing, Load side (Plug) housing, Line end insert, Fuse holder, Connecting link, Fuse (600V 30A max), Nut, Bolt, Washers & Lugs, Lubricant, HM53 inhibitor or equivalent, Load side cable, Run connection cable
- Prepare Load Side Housing for Cable
WARNING: Risk of shock, disconnect power before installation. Measure the load side cable diameter. Refer to Table 1 in the documentation to select the corresponding section on the load side (plug) housing. Cut off any remaining sections of the housing to match the size referenced in the Range column of Table 1.
- Clean and Strip Load Side Cable
Thoroughly clean approximately 8 inches along the load side cable end. Apply lubricant and insert the cable through the small hole in the load side (plug) housing. Push the cable through a sufficient distance to allow for 3/8 inch of insulation stripping. Strip the insulation a distance of 3/8 inch. CAUTION: Do not over strip the insulation.
- Crimp Fuse Holder
Insert the stripped load side cable into the crimp barrel of the fuse holder. Using the recommended tool and die from Table 2, securely crimp the fuse holder onto the cable.
- Install Fuse Holder into Load Side Housing
Lightly apply lubricant to the outside of the fuse holder. Insert the wood dowel into the fuse holder socket and brace the free end of the dowel against a firm surface. Push the load side (plug) housing forward until the fuse holder snaps securely into position. Wipe off any excess lubricant.
- Insert Fuse or Connecting Link
Insert a 13/32 inch by 1 1/2 inch fuse (600 Volt, 30 Amp maximum) or the connecting link into the load side (plug) housing. WARNING: DO NOT use a glass body fuse.
- Prepare Y-Type Housing and Run Cable
For a run connection, select and cut the correct cut-off ring on the Y-Type housing for the cable being used. Cut and bevel the cable insulation. Apply lubricant to the end of the cable and the cut opening of the housing. Slide the cable through until it extends 2 to 3 inches beyond the housing. Strip the insulation to fit the compression lugs.
- Crimp Lugs and Apply Inhibitor
Crimp the lugs onto the stripped cable ends using the proper crimping tool, ensuring the pad portions of the lugs are back to back. If using aluminum cable, wire brush the pads of the lugs, apply HM53 inhibitor or equivalent on the pads, and then wipe off any excess inhibitor.
- Assemble and Tighten Bolted Insert
Assemble the insert components as shown in the illustration, including the nut, bolt, Belleville washers, and lugs. Tighten the bolted assembly securely.
- Install Line End Insert into Y-Type Housing
Apply lubricant to the line end insert as indicated. Slide the Y-Type housing up to the bottom of the line end insert. Push the line end insert into the opening of the Y-Type housing. While pulling on the cables and holding the Y-Type housing, slide the housing toward the line end insert. Push the line end insert until it is fully seated in the housing.
- Connect Load Side to Line End
Lubricate the male and female components of the load side (plug) housing and the line end insert. Insert the load side (plug) housing, with the installed link or fuse clip, into the line end insert until it is fully connected.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.