Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274FLR1-C0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

ABB Installation Products 274FLR1-C0220 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 783786499687


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR1-C0220 Molded Current Limiting Fuse Housing is a compact, high-reliability solution for medium-voltage electrical protection in industrial and utility applications. Designed for 15.5kV nominal fuse voltage ratings, this housing integrates seamlessly into medium-voltage distribution systems, providing critical overcurrent protection while maintaining operational safety. The molded construction delivers inherent insulation and environmental resistance, ensuring long-term durability in demanding conditions. Key features include two capacitive test ports for non-invasive fuse testing, enabling quick diagnostics without system shutdown. The housing accommodates cable insulation diameters from 0.805 to 1.060 inches (20-27mm), supporting both aluminum conductors sized 2 AWG stranded compressed and 1 AWG solid compact configurations. This versatility simplifies installation across diverse electrical infrastructure projects, from substations to industrial motor control centers. The compact design of the 274FLR1-C0220 optimizes panel and enclosure space, making it ideal for installations where footprint is a constraint. The product is part of ABB’s Installation Products catalog, a trusted line for electrical infrastructure components. Applications include medium-voltage motor starters, transformers, and distribution panels where precise current limiting and fault protection are required. The fuse housing supports primary fuse holders (2 units) and secondary fuse clips (1 unit), aligning with ABB’s T4075PSF1, T4050PSF1, and T6150PS1 series specifications for standardized integration. Temperature rise is rated at 55°C, ensuring stable performance under continuous load conditions.
  • Nominal fuse voltage rating: 15.5kV
  • Two capacitive test ports for non-invasive fuse testing
  • Cable insulation diameter range: 0.805–1.060 in (20–27mm)
  • Supports aluminum conductors: 2 AWG stranded compressed or 1 AWG solid compact
  • Compact molded housing for space-constrained installations

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

274FLR1-C0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Aluminum Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Aluminum Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

274FLR1-C5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.

274FLR1-B5230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

Frequently Asked Questions

What is the product's primary application?

The Elastimold 274FLR protects light duty underground distribution systems, including sub-loops and radial taps. It replaces existing 200 Amp loadbreak tap elbows.

What voltage class is the 274FLR designed for?

The 274FLR is designed for 25/28kV voltage class applications.

What is the nominal fuse voltage for this product?

The nominal fuse voltage for the 274FLR is 16.2kV phase to ground.

What is the symmetrical interrupting capability?

The 274FLR has a symmetrical interrupting capability of 50,000 Amps.

Is the 274FLR suitable for submersible applications?

Yes, the 274FLR is fully sealed and submersible when used with ECS series sealing kits.

Does the 274FLR product include a fuse?

No, the fuse for the 274FLR is ordered separately.

How is a blown fuse indicated on the 274FLR?

The 274FLR has built-in voltage test points for quick and convenient blown fuse indication.

What industry standards does the 274FLR meet?

The 274FLR meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards.

What items are included in the 274FLR kit?

Each kit contains an elbow connector housing, crimp connector, probe lug, lubricant, installation instructions, crimp chart, and a V.D Cap-Peroxide.

How is the correct housing size selected?

The correct housing size (H code) is selected based on the desired fuse size and voltage.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides detailed instructions for the safe installation and initial assembly of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and grounding.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Allen Wrench (torque limiting), Wire brush, Crimp tool, Hotstick (live-line tool), Wire strippers

Supplies needed:

Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, Copper wire (No. 14 AWG / 2.5mm), Optional 200ECS Cold Shrink Cable Seal

  1. De-energize Apparatus and Inspect Components

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts. Check package contents for completeness and proper fit with cable and/or mating products. Thread the probe into the compression lug to check threads; if resistance is encountered, check for damage and replace the component. Read all instructions before starting and maintain cleanliness.

  2. Train and Cut Cable

    Using the bushing centerline as a reference, cut excess cable off 20 inches minimum beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable if used. Remove the jacket from the excess cable length remaining AND the distance of 'A' (fuse body length: 11-1/2 inches for FLR-1, 15-3/4 inches for FLR-3) plus 7-3/8 inches from the bushing centerline. If a Cable Seal kit is used, follow its instructions. Otherwise, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum of cable to terminate.

  3. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches from the cable end, ensuring a square cut and taking care not to nick the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, referring to the crimp chart provided with the lug for tool information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable.

  4. Remove Insulation Shield and Clean Insulation

    Remove the insulation shield 5-1/2 inches from the end of the lug. Bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  5. Lubricate and Insert Cable into Cable Half

    Apply lubricant (supplied) to the outside of the connector, cable insulation, conductive shield, and the cable half of the Fused Elbow cable entrance end. DO NOT SUBSTITUTE lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This allows the fuse to be tightened before bottoming on the rubber.

  6. Install and Hand Tighten Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. CAUTION: The fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.

  7. Assemble and Lock Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  8. Lubricate and Assemble Elbow Halves

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4 inch. Ensure the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other.

  9. Insert Probe and Tighten

    Insert the probe into the probe connector. It may be necessary to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread the probe. To tighten, use the special torque limiting allen wrench supplied; insert the short end of the wrench into the hole in the probe and tighten until the wrench bends and remains bent.

  10. Position and Tighten Hose Clamp

    Position the hose clamp as shown in the diagram (referencing the document's diagram) and tighten it. DO NOT OVERTIGHTEN.

  11. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eye. Finish installing the 200ECS jacket seal if used. Twist all neutral wires, exercising care not to damage grounding eyes, and connect to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  12. Lubricate and Connect Elbow to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection using a full insulated 'hotstick' type live-line tool. DO NOT OPERATE BY HAND. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.