ABB - Installation Products 274FLR1-C0240 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

ABB Installation Products 274FLR1-C0240 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 783786445370


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products 274FLR1-C0240 is a molded current-limiting fuse housing designed for robust medium-voltage electrical protection. This compact unit is engineered for industrial and utility applications, supporting nominal fuse voltages up to 15.5kV. It features two capacitive test ports, enabling safe, non-intrusive fuse testing without system interruption, thereby enhancing operational continuity and maintenance efficiency. The housing is compatible with cable insulation diameters ranging from 0.805 to 1.060 inches (20-27mm) and accommodates aluminum conductors, specifically 1/0 AWG stranded compressed or 2/0 AWG solid compact configurations. The specified tightening torque for secure connections is 2-2.5 Nm using a PZ2 driver. It meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards. The housing is padlockable when open and sealable when closed. Cable temperature ratings include CU 60, 75, and 90°C.
  • Molded current-limiting fuse housing for medium-voltage protection
  • Nominal fuse voltage rating of 15.5kV
  • Two capacitive test ports for safe, non-intrusive fuse testing
  • Accommodates cable insulation diameters from 0.805 to 1.060 inches (20-27mm)
  • Supports aluminum conductors: 1/0 AWG stranded compressed, 2/0 AWG solid compact

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.9400 L
Package Weight (Metric)
3.6020 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Aluminum Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Aluminum Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

274FLR1-C5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.

274FLR1-B5230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR1-C0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

Frequently Asked Questions

What is the product's primary application?

The Elastimold 274FLR protects light duty underground distribution systems, including sub-loops and radial taps. It replaces existing 200 Amp loadbreak tap elbows.

What voltage class is the 274FLR designed for?

The 274FLR is designed for 25/28kV voltage class applications.

What is the nominal fuse voltage for this product?

The nominal fuse voltage for the 274FLR is 16.2kV phase to ground.

What is the symmetrical interrupting capability?

The 274FLR has a symmetrical interrupting capability of 50,000 Amps.

Is the 274FLR suitable for submersible applications?

Yes, the 274FLR is fully sealed and submersible when used with ECS series sealing kits.

Does the 274FLR product include a fuse?

No, the fuse for the 274FLR is ordered separately.

How is a blown fuse indicated on the 274FLR?

The 274FLR has built-in voltage test points for quick and convenient blown fuse indication.

What industry standards does the 274FLR meet?

The 274FLR meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards.

What items are included in the 274FLR kit?

Each kit contains an elbow connector housing, crimp connector, probe lug, lubricant, installation instructions, crimp chart, and a V.D Cap-Peroxide.

How is the correct housing size selected?

The correct housing size (H code) is selected based on the desired fuse size and voltage.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and preparation of the 274FLR Loadbreak Fused Elbow Connector, including cable training, preparation, and assembly of components. Ensure all apparatus are de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Cutting tool, Wire brush, Crimp tool, Special torque limiting allen wrench (supplied), Probe wrench (supplied), Allen wrench (supplied), Hotstick (for operation and cap removal)

Supplies needed:

274FLR Loadbreak Fused Elbow Connector kit (includes Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Probe Wrench, Allen Wrench, Lubricant), UD cable (concentric neutral and extruded insulation shielding), Appropriate Elastimold cable shield or grounding device (if other UD cable types), Optional 200ECS Cold Shrink Cable Seal, No. 14 AWG / 2.5mm copper wire, Appropriate connector for grounding neutral wires, HV insulated cap(s) or connector(s) (to replace shipping covers)

  1. Prepare for Installation and Ensure Safety

    Before beginning, ensure all apparatus are de-energized to prevent serious or fatal injury. Inspect all components of the 274FLR kit for damage, proper rating, and compatibility with mating parts. Check the contents of the package to ensure completeness. Read the entire installation instructions and have all required tools at hand, maintaining cleanliness throughout the procedure. If the product came with shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging.

  2. Train Cable and Remove Jacket

    Using the bushing centerline as a reference, cut excess cable at least 20 inches beyond the bushing. If using an optional 200ECS Cold Shrink Cable Seal, slide it onto the cable. Remove the cable jacket for a distance of 'A' (15-3/4 inches for FLR-3, or 11-1/2 inches for FLR-1) plus 7-3/8 inches from the bushing centerline. If not using a cable seal kit, unwrap and fold the concentric neutral wires back over the jacket and bind them. Finally, squarely cut off the cable a distance of 'A' from the bushing centerline, leaving a minimum of 7-3/8 inches of cable to terminate.

  3. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches from the cable end, ensuring a square cut without nicking the conductor. Wire brush the bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, referring to the crimp chart provided with the lug. Start crimping at the crimp line mark and rotate 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end by a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Lubricate and Insert Cable Half Housing

    Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Do not substitute the lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A' of the housing. This positioning allows the fuse to be tightened correctly without bottoming on the rubber.

  5. Install and Hand Tighten the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. Exercise caution as the fuse stud will fracture if over-torqued. After hand tightening, pull the cable half housing up against the bottom of the tightened fuse.

  6. Assemble and Lock the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in this position. Tighten the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that its test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Halves and Insert Probe

    Apply the supplied lubricant to the elbow half of the fused elbow. Assemble the elbow half to the cable half, ensuring the cuff of the cable half overlaps the elbow half by 3/4 inch. Verify that the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; you may need to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread the probe. Use the special torque-limiting allen wrench supplied to tighten the probe by inserting the short end into the hole in the probe and tightening until the wrench bends and remains bent. Finally, position the hose clamp as shown in the diagram and tighten it, but do not overtighten.

  8. Connect Concentric Neutral Wires to Ground

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on both the elbow housing and the cable housing. Twist the wire tightly, taking care not to damage the grounding eyes. If a 200ECS jacket seal was used, finish installing it according to its instructions. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack is provided in the wires for proper elbow operation.

  9. Lubricate for Final Connection (De-energized)

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Do not operate the elbow by hand; use a full insulated 'hotstick' type tool as per operating instructions and company safety practices.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.