Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274FLR1-C5240 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

ABB Installation Products 274FLR1-C5240 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 075114209588


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR1-C5240 molded current limiting fuse housing is a compact, high-reliability solution for medium-voltage distribution systems requiring precise overcurrent protection. Designed for nominal 15.5kV systems, this fuse housing accommodates cable insulation diameters from 0.805 inch to 1.060 inch (20-27mm), making it compatible with a wide range of conductor sizes. The housing features two capacitive test ports for safe and efficient fault detection without system de-energization. Constructed from bi-metal material, the 274FLR1-C5240 ensures long-term durability and consistent performance in harsh industrial environments. It supports conductor sizes up to 1/0 AWG stranded compressed and 2/0 AWG solid compact, providing flexibility for various cable configurations. The small housing design optimizes space in switchgear and panel applications while maintaining robust protection standards. Ideal for utility substations, industrial power distribution, and renewable energy integration, this fuse housing delivers reliable current limitation to protect downstream equipment from fault conditions. Its compact form factor and tested compatibility with standard cable diameters reduce installation complexity and downtime. The 274FLR1-C5240 is part of ABB’s Installation Products series, ensuring compatibility with industry-standard fuse components and adherence to stringent electrical safety protocols.
  • Nominal voltage rating: 15.5kV for medium-voltage applications
  • Cable insulation compatibility: 0.805"–1.060" (20–27mm diameter)
  • Bi-metal construction for durability and reliability
  • Two capacitive test ports for safe fault detection
  • Supports 1/0 AWG stranded compressed and 2/0 AWG solid compact conductors

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.8900 L
Package Weight (Metric)
3.5790 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.

274FLR1-B5230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR1-C0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR3-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR3-B5230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

Frequently Asked Questions

What is the primary application of the 274FLR elbow?

The Elastimold 274FLR protects light duty underground distribution systems, including sub-loops and radial taps, by replacing existing 200 Amp loadbreak tap elbows.

Is the 274FLR suitable for submersible use?

Yes, the 274FLR is fully sealed and submersible when used with ECS series sealing kits.

Are sealing and grounding kits recommended for the 274FLR?

For safety purposes, a sealing and grounding kit is highly recommended with the loadbreak elbow.

What industry standards does the 274FLR meet?

The 274FLR meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47.

Is the fuse included with the 274FLR elbow connector?

No, the fuse is ordered separately.

Does the 274FLR elbow include a test point?

Yes, it has built-in voltage test points for quick and convenient blown fuse indication.

What is the interrupting capability of the 274FLR elbow?

The 274FLR has a full-range current-limiting fusing with 50kA symmetrical interrupting capability.

What is the current rating range for the 274FLR fuse?

The current rating for the fuse is 6-20 Amp.

What is the nominal fuse voltage for the 274FLR?

The nominal fuse voltage (phase to ground) for the 274FLR is 16.2kV.

What is the operating voltage class for the 274FLR?

The 274FLR is designed for 25/28kV voltage class systems.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 274FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and neutral connections.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Allen Wrench (special torque limiting), Hotstick, Wire brush, Crimp tool, Wire strippers, Vent stick

Supplies needed:

Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, UD cable (with concentric neutral and extruded insulation shielding), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for ground), Optional 200ECS Cold Shrink Cable Seal, HV insulated cap(s) or connector(s)

  1. Perform Initial Safety Checks and Component Verification

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents to ensure they are complete and undamaged. Check all components for proper fit with the cable and/or mating products. Verify threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component. Read all instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.

  2. Prepare the Cable for Termination

    Using the bushing centerline as a reference, cut excess cable off 20 inches minimum beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable. Remove the jacket from the excess cable length remaining AND the distance of 'A' (11-1/2 inches for FLR-1, 15-3/4 inches for FLR-3) plus 7-3/8 inches from the bushing centerline. If a Cable Seal kit is used, follow its instructions; otherwise, unwrap and fold the Concentric Neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum of cable to terminate. Cut 1-1/8 inches from the cable end, squarely, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Crimp the unthreaded end of the compression lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug. Bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Apply Lubricant and Assemble Cable Half

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable half of the Fused Elbow cable entrance end. DO NOT SUBSTITUTE lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'.

  4. Install the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. CAUTION: The fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.

  5. Assemble the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that the flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position and tighten the setscrews using the special torque limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  6. Assemble the Elbow Half and Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half of the fused elbow. Ensure the cuff of the cable half overlaps the elbow half by 3/4 inch. Verify that the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; it may be necessary to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread the probe. To tighten, use the special torque limiting allen wrench supplied; insert the short end of the wrench into the hole in the probe and tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  7. Connect the Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eye. Finish installing the 200ECS jacket seal if it was used. Twist all neutral wires, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  8. Connect the Fused Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. WARNING: Lubricate ONLY IF the transformer and elbow are known to be de-energized. Operate the connection using a full insulated 'hotstick' type live-line tool. DO NOT OPERATE BY HAND.

  9. Replace a Cleared Fuse

    DANGER: DO NOT ATTEMPT TO REPLACE THE FUSE IF THE FUSED ELBOW IS ENERGIZED, as this will result in serious or fatal injury. With the de-energized elbow removed from the bushing, use the torque limiting wrench to remove the probe. Loosen the hose clamp on the body of the elbow. Insert a vent stick between the Fused Elbow cable half and probe half to aid separation of the halves. Remove the probe connector from the fuse by loosening the allen setscrew. Unscrew the cleared fuse from the cable half by hand. Install a new fuse by following steps 4 through 6 of these instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.