ABB - Installation Products 274FLR1-B5230 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact. No Sealing Kit.

ABB Installation Products 274FLR1-B5230 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 075114330473


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR1-B5230 is a molded current limiting fuse housing designed for medium-voltage electrical distribution systems. This unit is rated for a nominal fuse voltage of 15.5 kV and features two capacitive test ports for diagnostic and maintenance procedures. Its compact design is suitable for space-constrained installations, accommodating cable insulation diameters ranging from 0.635 to 0.905 inches. The housing is compatible with bi-metal conductors, supporting 1 AWG stranded compressed or 1/0 AWG solid compact cable sizes. Engineered for use with gG type fuses up to 125A, it provides trip class 10 protection. The molded construction ensures robust mechanical strength and environmental resistance for long-term reliability in demanding operating environments. Applications include medium-voltage motor control centers, switchgear assemblies, and power distribution panels where current limiting and fault isolation are critical. This housing is designed to meet IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards. It offers 50,000 Amp symmetrical interrupting capability and is suitable for 25/28kV voltage class systems. The housing is fully sealed and submersible when used with appropriate sealing kits. Key features include hot stick operable loadbreak elbow switching capabilities and a split center section for easy fuse replacement. The built-in voltage test points facilitate quick and convenient blown fuse indication. Note: The fuse is ordered separately. This product is distributed by Gross Automation.
  • Molded construction for robust mechanical strength and environmental resistance.
  • Rated for 15.5 kV nominal fuse voltage.
  • Two capacitive test ports for diagnostics and maintenance.
  • Accommodates cable insulation diameters from 0.635 to 0.905 inches.
  • Compatible with 1 AWG stranded compressed or 1/0 AWG solid compact bi-metal conductors.

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Material
Molded
Series
274FLR1
Size
Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 kV
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-K2230-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR1-C0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR3-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR3-B5230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

274FLR1-D0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

Frequently Asked Questions

What shield adapter is needed for Unishield Cables?

For Unishield Cables, the shield adapter part number is 10TL-W, where "W" is determined by the cable's insulation diameter. Alternatively, add the suffix "-TL" to the part number.

What is the product's main application?

The Elastimold 274FLR protects light duty underground distribution systems by combining full-range current-limiting fusing with hot stick operable, loadbreak elbow switching. It replaces existing 200 Amp loadbreak tap elbows.

What voltage class does the 274FLR support?

The 274FLR is designed for 25/28kV voltage class systems. Its nominal fuse voltage is 16.2kV phase to ground.

What is the current rating of the fused elbow?

The current rating for the fused elbow is 6-20 Amp. It also has a 50,000 Amp symmetrical interrupting capability.

Is the 274FLR suitable for submersible applications?

Yes, the 274FLR is fully sealed and submersible when used with ECS series sealing kits. It also insulates, shields, and eliminates exposed live parts.

Is the fuse included with the 274FLR elbow?

No, the fuse for the 274FLR elbow is ordered separately.

What industry standards does the 274FLR meet?

The 274FLR meets IEEE 386 and ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards.

What items are included in the 274FLR kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, lubricant tubes, installation instructions, a crimp chart, and a V.D Cap-Peroxide.

Are sealing and grounding kits required for installation?

For safety purposes, a sealing and grounding kit with the loadbreak elbow is highly recommended.

What sealing kit is used for Jacketed Concentric Neutral Cables?

For Jacketed Concentric Neutral Cables, use the 200ECS sealing kit or add suffix "-S" for cables with a nominal O.D. between 0.80-1.50 inches.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 274FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and neutral wire connection.

Estimated time: 1h

Tools needed:

Probe Wrench, Allen Wrench (torque limiting), Wire brush, Crimp tool, Hotstick

Supplies needed:

Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, No. 14 AWG / 2.5mm copper wire, Appropriate ground connector, Optional 200ECS Cold Shrink Cable Seal

  1. De-energize Apparatus and Prepare for Installation

    Ensure all apparatus is de-energized before beginning installation. This product must be installed by competent personnel trained in high voltage electrical safety practices. Inspect all package contents for completeness and damage, and verify component compatibility with the cable and mating products. Have all required tools ready and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Termination

    Using the bushing centerline as reference, cut excess cable, then remove the cable jacket for the specified length. If using a Cable Seal kit, follow its instructions; otherwise, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable to the required length, ensuring no nicks to the conductor. Wire brush bare aluminum conductors immediately.

  3. Install and Crimp the Compression Lug

    Install the compression lug onto the prepared conductor, rotating it to spread inhibitor. Crimp the unthreaded end of the lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Refer to the crimp chart provided with the lug. Carefully wipe any excess inhibitor from the outside of the lug and cable.

  4. Prepare Cable Insulation and Lubricate Components

    Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end by 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue. Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Do not substitute lubricant.

  5. Assemble Cable Half and Install Fuse

    Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand tighten it into the cable connector. CAUTION: Fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.

  6. Install Probe Connector and Align Test Point

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the mating bushing. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied. Rotate the cable half of the Fused Elbow so that its test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Half, Probe, and Hose Clamp

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half, ensuring the cuff overlaps by 3/4 inch and the probe connector faces the opening. The two test points should be in line. Insert the probe into the probe connector, pushing on the cable if needed for alignment. Hand start the threads, then tighten using the special torque-limiting allen wrench until it bends and remains bent. Position and tighten the hose clamp as shown, but do not overtighten.

  8. Connect Concentric Neutral Wires to Ground

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through each grounding eye on the elbow and cable housings and twist tightly, taking care not to damage the eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires and connect them to ground using an appropriate connector, providing adequate slack for elbow operation.

  9. Lubricate and Connect Elbow to Bushing (De-energized)

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Do not operate by hand; use a full insulated 'hotstick' type live-line tool for connection as per operating instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.