Contact for Pricing
Overview
- 25kV phase-to-ground, 43.3kV phase-to-phase rated
- Accommodates cable insulation diameters from 0.805" to 1.060"
- Bi-metal compression lug for copper/aluminum compatibility
- Integrated test point for safe circuit integrity testing
- 62-inch ground lead pre-installed with rivet for immediate grounding
Specifications
Amperage Rating | 200 A |
Application | 25kV 200 Amp, |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection Type | Compression Lug |
Current Rating | 200 A |
Insulation | True |
Material | Bi-Metal |
Material | Housing - EPDM-Rubber |
Series | 262LR |
Size | 0.805-1.060 inch |
Special Features | 62 inch Ground Lead Installed Through Grounding Eye Utilizing Rivet |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

274RLR-H-5240
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
252LR-D2120
12/20 (24) kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 22.61mm - 30.99mm, Copper Compression Lug, Conductor Size 120mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
162LR-B5240-CS2089
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Includes 62 inch Ground Lead Installed Through Grounding Eye Utilizing Rivet.
K656LR-JAC02
15/25kV, 600 Amps, Separable Cable joint Elbow with Test Point, Includes Elbow Connector Housing, Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and Lubricant. Cable Insulation Range 0.98 to 1.18 inch. Shear Bolt Lug AC02 Range 4/0 to 500 kcmil Stranded - Compressed - Solid - Compact.
262LR-C2250
28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
K655ESA-18-CS2090
Shielded Surge Arrester, ESA Elbow Surge Arrester, 15/25kV, 600 Amp, MCOV KV RMS is 15.30. Any Customer Modifications CS2090 - For AISI 316 Grade Stainless Steel External Components Only.
K151SR-A2250
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp ChartFrequently Asked Questions
Is an integral jacket seal an option?
Yes, an optional integral jacket seal is available for the product.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow available for 15 kV and 25 kV series, incorporating innovative design and manufacturing experience.
What are the voltage and current ratings?
The enhanced Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV applications.
What safety features are included?
Safety features include improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
Is the product RUS accepted?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA). This authorizes its use in rural infrastructure construction.
What standards does the product comply with?
The product complies with IEEE 386 and holds ANSI certification. It also has Rural Utilities Service (RUS) acceptance.
What is the purpose of the rigid probe support?
The rigid probe support ensures proper switching and easy probe installation.
What material is the pulling eye made of?
The pulling eye is made of robust stainless-steel, which promotes durable hotstick control.
Are there different grounding options available?
Yes, the enhanced design includes dual grounding eye positions for increased safety.
Is an integral jacket seal an option?
Yes, an optional integral jacket seal is available for the product.
How to Install 261LR and 262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of 261LR and 262LR Loadbreak Elbow Connectors, including cable preparation, elbow assembly, and grounding.
Estimated time: 1h
Tools needed:
Probe Wrench, Hotstick (Live-line tool), Crimp tool, Wire brush, Suitable sensing device (for capacitive test point)
Supplies needed:
261LR or 262LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), UD Cable (appropriate type), ElastimoldR 25kV class 200ampere loadbreak bushing or accessory device, No. 14 AWG / 2.5mm copper wire (or equivalent) for grounding, Appropriate connector for neutral wires, Cold shrink tube (if using 200ECS sealing kit), Conductive copper tape (if using 200ECS-G2 kit), Silicone lubricant (for test point cap)
- Prepare Cable for Termination
DANGER: Ensure all apparatus is de-energized before beginning installation. Train the cable to ensure adequate slack for future operation. Prepare the cable end by cutting it squarely at the bushing centerline. Depending on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), remove the outer jacket and/or copper tape shield to the specified dimensions (e.g., 9-5/8 inches for outer jacket, 7-1/8 inches for copper tape shield). Manage neutral or drain wires as per your cable type's instructions, ensuring extra length for grounding. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable now.
- Prepare Conductor and Insulation
Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove the insulation shield as shown in the template (6-7/8 inches / 175mm from the lug end) and bevel the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble Elbow Housing and Probe
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect Grounding and Neutrals
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete the grounding.
- Connect Elbow to Bushing
DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.