ABB - Installation Products 262LR-C2250 - 28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
More images
ABB - Installation Products

262LR-C2250

UPC: 075114397353


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

ABB Installation Products 262LR-C2250 is a 28kV, 200 amp loadbreak elbow connector designed for medium-voltage cable systems requiring safe, reliable loadbreak operations. This connector accommodates cable insulation diameters from 0.805 to 1.060 inches and supports 2/0 stranded or compressed copper conductors and 3/0 solid or compact copper wire sizes. The unit includes a copper compression lug for secure termination, a probe for loadbreak functionality, and a probe wrench for installation. A tube of lubricant is provided to ensure proper sealing and operation during mating cycles. The kit also contains a crimp chart and detailed installation instructions for field deployment. This elbow connector is commonly used in utility, industrial, and commercial medium-voltage distribution systems where loadbreak capability is required for safe maintenance and switching operations. The absence of a sealing kit allows for compatibility with field-installed sealing systems or site-specific requirements.
  • 28kV, 200 amp rated loadbreak elbow connector
  • Compatible with .805–1.060 inch cable insulation diameters
  • Supports 2/0 stranded or compressed and 3/0 solid or compact copper wire
  • Includes copper compression lug, probe, probe wrench, lubricant, crimp chart, and instructions
  • Designed for medium-voltage distribution systems requiring loadbreak functionality

Specifications

Amperage Rating
200 A
Application
28 kV, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25/28kV, Load Break,200 Amp Elbow without Test Point, No Sealing Kit. .890 inch - 1.220 inch Cable Insulation Diameter. Wire Size 2/0 Stranded/Compressed, 3/0 Solid/Compact, 67.43 mm2. Copper Compression Lug. ANSI/IEEE Standard 386. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart, Installation Instructions.

261LR-D2250

25/28kV, Load Break,200 Amp Elbow without Test Point, No Sealing Kit. .890 inch - 1.220 inch Cable Insulation Diameter. Wire Size 2/0 Stranded/Compressed, 3/0 Solid/Compact, 67.43 mm2. Copper Compression Lug. ANSI/IEEE Standard 386. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart, Installation Instructions.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
Shielded Surge Arrester, ESA Elbow Surge Arrester, 15/25kV, 600 Amp, MCOV KV RMS is 15.30. Any Customer Modifications CS2090 - For AISI 316 Grade Stainless Steel External Components Only.

K655ESA-18-CS2090

Shielded Surge Arrester, ESA Elbow Surge Arrester, 15/25kV, 600 Amp, MCOV KV RMS is 15.30. Any Customer Modifications CS2090 - For AISI 316 Grade Stainless Steel External Components Only.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp Chart

K151SR-A2250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp Chart
Shielded Surge Arrester, ESA Elbow Surge Arrester, 15/25kV, 600 Amp, MCOV KV RMS is 15.30

K655ESA-18

Shielded Surge Arrester, ESA Elbow Surge Arrester, 15/25kV, 600 Amp, MCOV KV RMS is 15.30
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.182 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 to Compacted/Solid 250 kcmil. With Insulated Cap and Shrink-Fit Jacket Seal Kit.

K655ETP-K0270-DRG-S

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.182 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 to Compacted/Solid 250 kcmil. With Insulated Cap and Shrink-Fit Jacket Seal Kit.
15kv, 600 Amps, Deadbreak Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug and Insulated Cap kit. Has Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch. Connector Range 350 kcmil Stranded or Compressed to 400 kcmil Solid or Compact. No Grounding or Sealing Kit.

656CETP-L0300-DRG

15kv, 600 Amps, Deadbreak Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug and Insulated Cap kit. Has Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch. Connector Range 350 kcmil Stranded or Compressed to 400 kcmil Solid or Compact. No Grounding or Sealing Kit.
600 Amp, 15/25kv, Spiking Elbow (with Spiking Contact, Insulated Plug and Cap, Stud, Lug and Cable Adapter). Does not include Sealing Kit. Aluminum Lug, Cable Insulation Diameter 1.180-1.465. Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Installation Instructions and Crimp Chart included.

K656SELR-L0330

600 Amp, 15/25kv, Spiking Elbow (with Spiking Contact, Insulated Plug and Cap, Stud, Lug and Cable Adapter). Does not include Sealing Kit. Aluminum Lug, Cable Insulation Diameter 1.180-1.465. Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Installation Instructions and Crimp Chart included.

Frequently Asked Questions

What standards and certifications does the elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification. It also has RUS acceptance.

Does the elbow offer an integral jacket seal?

Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.

Is the Elastimold elbow compatible with Elastimold bushings?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

Does the Elastimold elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA. This authorizes its use in rural infrastructure construction.

What are the voltage ratings for the Elastimold loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

Is the Elastimold elbow compatible with Elastimold bushings?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards and certifications does the elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification. It also has RUS acceptance.

Does the elbow offer an integral jacket seal?

Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.

Does the Elastimold elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA. This authorizes its use in rural infrastructure construction.

What are the voltage ratings for the Elastimold loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, including cable preparation, lug crimping, and final assembly.

Estimated time: 1h

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Wire strippers, Cable cutting tool, Hotstick

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), UD Cable, Copper wire (No. 14 AWG / 2.5mm), Appropriate neutral wire connector, Cold shrink tube (if using sealing kit)

  1. Perform Initial Safety Checks and Component Inspection

    DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed only by competent personnel trained in high voltage electrical safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check probe threads by threading the probe into the compression lug; replace if resistance is encountered.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for operation. Cut the cable squarely at the bushing centerline. Remove the outer jacket (if present) and prepare the neutral wires or copper tape shield according to your specific cable type's requirements, ensuring proper lengths and binding. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first.

  3. Prepare Cable End and Install Compression Lug

    Remove 2-1/8” (55mm) of the cable shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug, rotating it to spread inhibitor, and align its threaded hole with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove 6-7/8” (175mm) of the insulation shield and bevel the insulation end by a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Connect Grounding Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect Elbow to Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated 'hotstick' type tool as per operating instructions; DO NOT OPERATE BY HAND. Ensure positive control and push the elbow home with a fast, firm, straight motion to engage the internal lock.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.