ABB Installation Products 162LR-B5240-CS2089 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114392143
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp current rating for medium-voltage applications
- 15kV voltage rating with loadbreak capability for safe hot-swapping
- Bi-metal compression lug compatible with 1/0 or 2/0 AWG (53.49 mm²) conductors
- Cable insulation diameter range: 0.635" to 0.905"
- Includes 62" ground lead with rivet-installed grounding eye for safety
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Push-In |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | 62 inch Ground Lead Installed Through Grounding Eye Utilizing Rivet |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-C5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
K656LR-JAC02
15/25kV, 600 Amps, Separable Cable joint Elbow with Test Point, Includes Elbow Connector Housing, Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and Lubricant. Cable Insulation Range 0.98 to 1.18 inch. Shear Bolt Lug AC02 Range 4/0 to 500 kcmil Stranded - Compressed - Solid - Compact.
262LR-C2250
28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
K655ESA-18-CS2090
Shielded Surge Arrester, ESA Elbow Surge Arrester, 15/25kV, 600 Amp, MCOV KV RMS is 15.30. Any Customer Modifications CS2090 - For AISI 316 Grade Stainless Steel External Components Only.
K151SR-A2250
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp Chart
K655ETP-K0270-DRG-S
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.182 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 to Compacted/Solid 250 kcmil. With Insulated Cap and Shrink-Fit Jacket Seal Kit.
656CETP-L0300-DRG
15kv, 600 Amps, Deadbreak Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug and Insulated Cap kit. Has Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch. Connector Range 350 kcmil Stranded or Compressed to 400 kcmil Solid or Compact. No Grounding or Sealing Kit.Frequently Asked Questions
What material is used for the pulling eye?
The pulling eye is made of robust stainless steel, promoting durable hotstick control.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
Is an optional integral jacket seal available for the elbow?
Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.
What standards and certifications does the product meet?
The product is IEEE 386 compliant and has ANSI certification, in addition to RUS acceptance.
Does the enhanced loadbreak elbow have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for switching operations.
What material is used for the pulling eye?
The pulling eye is made of robust stainless steel, promoting durable hotstick control.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
Is an optional integral jacket seal available for the elbow?
Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.
How to Install 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for preparing cables, assembling the elbow connector, grounding, and connecting the 161LR or 162LR Loadbreak Elbow Connector to a de-energized bushing.
Estimated time: 1h 30m
Tools needed:
Cable cutters, Measuring tape, Cable strippers, Wire brush, Crimp tool (specific to compression lug), Probe wrench, Hotstick
Supplies needed:
Elbow Connector Housing (161LR or 162LR), Compression Lug, Probe, Lubricant (supplied, DO NOT SUBSTITUTE), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector for neutral wires, Vinyl tape (if applicable), Conductive copper tape (if applicable), Cold shrink tube (if using sealing kit), Cleaning solution/wipes
- Perform Safety and Pre-Installation Checks
Before beginning, ensure all apparatus are de-energized. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents for completeness and damage. Verify proper fit with cable and mating products, and check probe threads by hand-threading into the compression lug. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack (24-36 inches or 610-914mm) for operation. Prepare neutral wires or grounding braid according to your specific cable type (e.g., bind neutrals 7-3/4 to 8 inches back for non-jacketed, or remove 9-5/8 inches of outer jacket for jacketed cables). Cut excess cable squarely at the bushing centerline. If using a sealing kit (e.g., 200ECS), slide the cold shrink tube onto the cable loose end first.
- Prepare Cable End and Install Compression Lug
Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug per its manufacturer's chart, rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor. Remove the insulation shield 6-7/8 inches (175mm) back and bevel the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow and Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect Elbow to Bushing Plug
**DANGER:** CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with this step. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.