ABB Installation Products K151SR-A2250 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…
UPC: 075114397162
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp continuous current rating
- 15/25kV voltage class, 15.2kV max phase-to-ground
- Fully shielded, fully submersible molded rubber housing
- Accommodates cable insulation diameters from 0.575" to 0.740"
- Includes copper compression lug, test point, lubricant, and installation kit
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Copper |
Material | Molded Rubber, Copper |
Material | Housing - EPDM-Rubber |
Mounting Type | Direct Burial, Vault, Manhole |
Series | K151SR |
Series | K151 |
Size | 0.575-0.740 inch (Cable Insulation Diameter) |
Size | 0.575-0.740 inch (Insulation Diameter) |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B-2250
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
K655ETP-K0270-DRG-S
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.182 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 to Compacted/Solid 250 kcmil. With Insulated Cap and Shrink-Fit Jacket Seal Kit.
656CETP-L0300-DRG
15kv, 600 Amps, Deadbreak Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug and Insulated Cap kit. Has Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch. Connector Range 350 kcmil Stranded or Compressed to 400 kcmil Solid or Compact. No Grounding or Sealing Kit.
K656SELR-L0330
600 Amp, 15/25kv, Spiking Elbow (with Spiking Contact, Insulated Plug and Cap, Stud, Lug and Cable Adapter). Does not include Sealing Kit. Aluminum Lug, Cable Insulation Diameter 1.180-1.465. Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Installation Instructions and Crimp Chart included.
262LR-B2220
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.
161LR-C2250-SG3
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0. 200ECS-G3 Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.Frequently Asked Questions
What are the 25kV operating voltage ratings for the K151SR?
For 25kV, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV. It has a 125kV BIL impulse withstand rating.
What are the 15kV operating voltage ratings for the K151SR?
For 15kV, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV. It has a 95kV BIL impulse withstand rating.
What cable types and sizes are compatible with the K151SR?
It terminates UD cable with concentric neutral and extruded insulation shielding. It accommodates conductor sizes from No. 4 solid through 4/0 stranded and insulation diameters from 0.575 in through 1.220 in.
What is the application of the K151SR straight receptacle?
The K151SR connects a cable to another cable or apparatus. It requires an appropriate Elastimold® mating product and is suitable for 15 and 25kV systems.
What are the main features of the K151SR receptacle?
The K151SR is a 15/25kV, 200 Amp deadbreak straight receptacle with a fully shielded, submersible molded rubber housing. It features 100% peroxide-cured construction and a provision for ground wire connection.
What is the continuous current rating of the K151SR?
The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes. It also has a 10kA Sym momentary rating for 10 cycles.
Does the K151SR meet industry standards?
Yes, the K151SR meets ANSI/IEEE Standard 386, Latest Revision.
Are copper compression lugs compatible with all conductor types?
No, copper compression lugs are suitable only for all copper conductors. Bi-metal connectors are also available.
What items are included in the K151SR kit?
Each kit contains one straight receptacle housing, one receptacle pin connector, one tube of lubricant, installation instructions, and a crimp chart.
What cable types and sizes are compatible with the K151SR?
It terminates UD cable with concentric neutral and extruded insulation shielding. It accommodates conductor sizes from No. 4 solid through 4/0 stranded and insulation diameters from 0.575 in through 1.220 in.
How to Install the Elastimold 151SR/K151SR Straight Receptacle
This guide provides step-by-step instructions for preparing the cable, crimping the conductor, and installing the Elastimold 151SR/K151SR straight receptacle, including connection to a mating plug and proper grounding. Ensure all apparatus is de-energized before starting.
Estimated time: 1h
Tools needed:
Wire brush, Crimping tool, Rag, Approved solvent
Supplies needed:
Elastimold 151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, Cable, #14 AWG copper wire (or equivalent), Elastimold bail, Elastimold insulating plug (K150DP) (optional)
- Ensure Safety and Inspect Components
De-energize all apparatus during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating products. Read all instructions thoroughly and have all required tools at hand, maintaining cleanliness throughout the procedure.
- Prepare the Cable Jacket
For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, allowing sufficient concentric neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the end of the cable. Follow specific instructions for ECS or MA grounding devices if applicable.
- Prepare Conductor and Crimp Terminal
Remove 7/8 to 1 inch (or 1 3/4 to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Cut the conductor squarely; do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel which contains inhibitor. Crimp the socket terminal, starting at the crimp line imprinted on the barrel and rotating each successive crimp or indent 90 degrees. Carefully wipe excess inhibitor from the contact and cable insulation if using aluminum cable.
- Prepare Insulation and Clean
Remove the semi-conductive shield 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, ensuring not to cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket. Install an ECS or MA grounding device if applicable.
- Lubricate and Insert Cable into Receptacle
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing; do not substitute. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace the protective cover with an Elastimold insulating plug (K150DP), as the shipping cover is for dirt protection only and is not an insulating device.
- Connect to Mating Plug
Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care to ensure the nylon rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail.
- Ground the Cable
If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.