ABB - Installation Products 656CETP-L0300-DRG - 15kv, 600 Amps, Deadbreak Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug and Insulated Cap kit. Has Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch. Connector Range 350 kcmil Stranded or Compressed to 400 kcmil Solid or Compact. No Grounding or Sealing Kit.

ABB Installation Products 656CETP-L0300-DRG 15kv, 600 Amps, Deadbreak Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter…

UPC: 075114396899


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 656CETP-L0300-DRG is a 15kV, 600 Amp Deadbreak Combo-T Elbow Reducing Tap Plug kit engineered for reliable medium-voltage electrical connections in power distribution systems. This kit includes a stud, cable adapter, aluminum lug, and insulated cap, providing a complete solution for tap connections. The deadbreak design ensures safe disconnection by requiring the system to be de-energized before removal, enhancing personnel safety. The reducing tap plug functionality allows flexible system configurations, accommodating different conductor sizes within its specified range. The kit features a test point for convenient diagnostic checks and meets ANSI/IEEE Standard 386 for 15kV voltage class. The hollow bore design enables visual validation of the compression lug position before final assembly, reducing installation errors. The IEEE 386 color-coded PBT interface improves visibility, provides a seating indicator, and minimizes sticking during installation. The internal hex broach ensures proper installation torque, preventing cross-threading and ensuring reliable connections. This product is ideal for utility, industrial, and commercial power distribution networks where robust and dependable medium-voltage connections are required. The connector range supports 350 kcmil stranded or compressed conductors and 400 kcmil solid or compact conductors, with cable insulation diameter range from 1.180 to 1.465 inches. The kit does not include grounding or sealing components, which must be sourced separately if needed.
  • 15kV voltage class with 600 Amp continuous deadbreak connection
  • Deadbreak design ensures safe de-energized disconnection
  • Test point for convenient diagnostic checks
  • Accommodates 350 kcmil stranded/compressed or 400 kcmil solid/compact conductors
  • Cable insulation diameter range: 1.180 to 1.465 inches
  • Meets ANSI/IEEE Standard 386 for 15kV systems
  • Hollow bore design enables visual validation of lug positioning
  • IEEE 386 color-coded PBT interface for better visibility and reduced sticking

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Black
Conductor Range
350 kcmil to 400 kcmil
Connection Type
Deadbreak Combo-T Elbow Reducing Tap Plug
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum Lug
Size
Cable Insulation Diameter Range 1.180 to 1.465 inch, Connector Range 350 kcmil Stranded or Compressed to 400 kcmil Solid or Compact
Special Features
Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655ETP-N0410-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15/25kv, Spiking Elbow (with Spiking Contact, Insulated Plug and Cap, Stud, Lug and Cable Adapter). Does not include Sealing Kit. Aluminum Lug, Cable Insulation Diameter 1.180-1.465. Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Installation Instructions and Crimp Chart included.

K656SELR-L0330

600 Amp, 15/25kv, Spiking Elbow (with Spiking Contact, Insulated Plug and Cap, Stud, Lug and Cable Adapter). Does not include Sealing Kit. Aluminum Lug, Cable Insulation Diameter 1.180-1.465. Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Installation Instructions and Crimp Chart included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.

262LR-B2220

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0. 200ECS-G3 Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

161LR-C2250-SG3

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0. 200ECS-G3 Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 kcmil. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K656SR-J2270-SG3

15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 kcmil. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size #1 AWG Stranded or Compressed. 1/0 AWG Solid or Compact. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K656SR-L2230-SG3

15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size #1 AWG Stranded or Compressed. 1/0 AWG Solid or Compact. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700 to 750 kcmil or Compacted/Solid 900 kcmil.

K655DLR-P0380

15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700 to 750 kcmil or Compacted/Solid 900 kcmil.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and lubricant. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size 3/0 AWG Stranded or Compressed or Solid or Compact to 500 kcmil Stranded or Compressed or Solid or Compact.

K655LR-LAC02

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and lubricant. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size 3/0 AWG Stranded or Compressed or Solid or Compact to 500 kcmil Stranded or Compressed or Solid or Compact.

Frequently Asked Questions

What is the voltage rating of this deadbreak elbow tap plug?

This ABB deadbreak elbow tap plug has a voltage rating of 15kV.

What is the amperage rating for this tap plug kit?

The amperage rating for this tap plug kit is 600 Amps.

What is the cable insulation diameter range for this kit?

This kit is designed for a cable insulation diameter range of 1.180 to 1.465 inches.

What conductor sizes are compatible with this connector range?

The connector range is suitable for 350 kcmil stranded or compressed, and 400 kcmil solid or compact conductors.

Does this kit include a grounding or sealing kit?

No, this specific model does not include a grounding or sealing kit.

What components are included in this tap plug kit?

This kit includes a stud, cable adapter, aluminum lug, and an insulated cap.

Does this product have a test point?

Yes, this deadbreak combo-T elbow reducing tap plug kit features a test point.

How to Install the 656CETP Deadbreak Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 656CETP Deadbreak Elbow Connector, including cable preparation, lug crimping, and connection to mating apparatus. DANGER: All apparatus must be de-energized during installation. Failure to follow instructions will result in serious injury or death.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire brush, 600ATM assembly tool, Hotstick, Suitable voltage sensing device for capacitive test points, Wire strippers, Cable cutting tool

Supplies needed:

656CETP Deadbreak Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Lubricant), Cable (concentric neutral, flat metallic tape shield, fabric tape shield, longitudinally corrugated shield, Unishield, lead sheath, or semi-con shield), Vinyl plastic tape, Tape retainer (if fabric tape shield), Tape marker, Ground wire (minimum No. 14 AWG Copper), Suitable connector for ground wire, Waterproofing material for cable jacket (recommended), Mating apparatus bushing, DR(G), ESA, GLR, or LR (if using tap plug interface), Insulated cap or elbow (for final assembly), Silicone grease

  1. Prepare for Installation and Position Cable

    Inspect all parts for damage, correct rating, and compatibility with mating parts. Ensure all required tools and supplies are at hand and maintain cleanliness. Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Measure and cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  2. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.

  3. Remove Outer Jacket and Prepare Cable Shield

    If using a 20MA or 21MA grounding device or 600ECS Jacket Cable Seal, refer to their specific installation instructions for outer jacket removal, shield connection, and grounding. Otherwise, remove the cable's outer jacket to the dimension shown in the product documentation. Fold back any shield wires. If your cable has a flat metallic tape shield, remove it and secure it with vinyl plastic tape to the specified dimension. For fabric tape shield, remove it and install a tape retainer and tape marker as indicated. If using a longitudinally corrugated shield, remove it and install a tape marker. For Unishield® or lead sheath cable, refer to the 10TL cable shield adapter instructions. If your cable has a semi-con shield, remove it to the specified dimensions, taking extreme care not to cut or nick the underlying cable insulation.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean the cable insulation, then lubricate it with the supplied lubricant, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length must be 4-3/8 to 4-11/16 inches (111mm-119mm). If not, redo the assembly.

  6. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Before crimping, measure the 'Check Dimension' (must be less than 6-1/2 inches / 165mm). Crimp the compression lug according to the supplied crimping instructions. After crimping, wipe all excess inhibitor from the lug and cable adapter. The distance from the end of the compression lug to the cable adapter must be 6-1/2 to 7-1/4 inches (165mm-184mm). If not, redo the assembly.

  7. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Apparatus

    WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect Elbow to Mating Apparatus

    Push the elbow onto the mating part. Using the 600ATM assembly tool, engage the hex broach in the contact assembly. Insert the contact assembly into the elbow interface to engage the stud. Tighten the contact assembly to 50-60 foot-pounds torque using the 600ATM assembly tool. DO NOT EXCEED 60 FOOT POUNDS TORQUE.

  10. Ground Cable Shield

    Insert one end of a ground wire (at least No. 14 AWG Copper) through the grounding eye and twist to form a small loop, avoiding damage to the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  11. Install Tap Plug Interface (Optional)

    Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following their respective product instructions.

  12. Verify Seating Indication

    Confirm complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side.

  13. Perform Voltage Test (Optional)

    The ELASTIMOLD® deadbreak elbow connector is equipped with an integral capacitance test point. To perform a voltage test, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Contamination or incorrect equipment can cause false readings. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.