ABB - Installation Products 161LR-C2250-SG3 - 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0. 200ECS-G3 Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

ABB Installation Products 161LR-C2250-SG3 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch.…

UPC: 075114398220


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 161LR-C2250-SG3 is a 15kV, 200 Amp loadbreak elbow designed for reliable medium-voltage cable termination in industrial and utility applications. This elbow accommodates cable insulation diameters from 0.805 inches to 1.060 inches, making it compatible with a wide range of medium-voltage cables. The unit features a copper compression lug rated for 2/0 AWG compressed/stranded or 3/0 AWG solid/compact conductors, ensuring secure electrical connections with minimal resistance. Included with the elbow is the 200ECS-G3 cold shrinkable sealing kit, which provides a watertight, corrosion-resistant termination. The seal incorporates a copper braid for effective grounding and a constant force spring to maintain consistent pressure, preventing loosening over time. This configuration is ideal for applications requiring durable, long-term performance in harsh environments. Key specifications include: - Voltage rating: 15kV - Amperage rating: 200 Amp - Cable insulation diameter range: 0.805" to 1.060" - Conductor size compatibility: 2/0 AWG (compressed/stranded) or 3/0 AWG (solid/compact) - Lug type: Copper compression - Seal type: 200ECS-G3 cold shrinkable with copper braid and constant force spring This ABB loadbreak elbow is engineered for medium-voltage cable terminations in power distribution systems, substations, and industrial facilities where reliable, loadbreak-capable connections are required. The included sealing kit ensures environmental protection and grounding integrity, reducing the risk of faults and extending service life.
  • 15kV voltage rating for medium-voltage applications
  • 200 Amp continuous current rating
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Copper compression lug for 2/0 AWG (compressed/stranded) or 3/0 AWG (solid/compact) conductors
  • Includes 200ECS-G3 cold shrinkable seal with copper braid and constant force spring for grounding and environmental protection

Specifications

Amperage Rating
200 A
Application
15 kV, 200 Amp. The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Special Features
200ECS-G3 Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 kcmil. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K656SR-J2270-SG3

15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 kcmil. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size #1 AWG Stranded or Compressed. 1/0 AWG Solid or Compact. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K656SR-L2230-SG3

15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size #1 AWG Stranded or Compressed. 1/0 AWG Solid or Compact. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700 to 750 kcmil or Compacted/Solid 900 kcmil.

K655DLR-P0380

15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700 to 750 kcmil or Compacted/Solid 900 kcmil.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and lubricant. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size 3/0 AWG Stranded or Compressed or Solid or Compact to 500 kcmil Stranded or Compressed or Solid or Compact.

K655LR-LAC02

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and lubricant. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size 3/0 AWG Stranded or Compressed or Solid or Compact to 500 kcmil Stranded or Compressed or Solid or Compact.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 650 or Compact/Solid 750/800 kcmil. Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring Included.

K655LR-K0360-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 650 or Compact/Solid 750/800 kcmil. Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring Included.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Shear Bolt Lug. Conductor Size Compressed-Stranded-Solid-Compact 500 to 750 kcmil. 200ECS Cold Shrinkable Jacket Seal Included.

656CETP-MAC03-S

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Shear Bolt Lug. Conductor Size Compressed-Stranded-Solid-Compact 500 to 750 kcmil. 200ECS Cold Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .760 to .950 inch. Aluminum Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No Sealing Kit.

K656LR-G0260

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .760 to .950 inch. Aluminum Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No Sealing Kit.

Frequently Asked Questions

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced loadbreak elbow for 15 kV and 25 kV series, incorporating innovative design for switching operations.

How does the elbow reduce life cycle costs?

It is optimized for switching operations, provides lifetime ease of operation, and has an improved seal system for traditional and jacket seal options.

What flexibility enhancements does the elbow offer?

It offers additional sizes, improved wider cable ranges, an easy order system, and an optional integral jacket seal.

What does RUS acceptance mean for this product?

RUS acceptance from the U.S. Department of Agriculture (USDA) authorizes its use in rural infrastructure construction and improvements.

What standards and certifications does the elbow meet?

The elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

How is the no-stick interface achieved?

The no-stick interface is achieved when the elbow is used with Elastimold bushings, as tested by NEETRAC.

What safety features does the loadbreak elbow include?

It includes improved insulation for 15 kV elbows, rigid probe support, a robust stainless-steel pulling eye, and dual grounding eye positions.

What are the voltage ratings for this elbow?

The enhanced Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series.

What does RUS acceptance mean for this product?

RUS acceptance from the U.S. Department of Agriculture (USDA) authorizes its use in rural infrastructure construction and improvements.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced loadbreak elbow for 15 kV and 25 kV series, incorporating innovative design for switching operations.

How to Install Elastimold 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and assembly of Elastimold 161LR and 162LR Loadbreak Elbow Connectors on various UD cables, including cable preparation, lug installation, elbow assembly, and grounding. Ensure all apparatus are de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Wire strippers/Cable preparation tools, Wire brush, Crimp tool (specific to compression lug), Probe wrench, Hotstick (insulated live-line tool), Cleaning cloths/wipes

Supplies needed:

Elastimold 161LR or 162LR Elbow Connector Housing, Compression Lug (appropriate for cable conductor), Probe, Lubricant (supplied with connector kit), Copper wire (No. 14 AWG / 2.5mm) for grounding, Appropriate connector for neutral wires, Cold shrink tube (if using specific sealing kits), Conductive copper tape (if using specific sealing kits), Vinyl tape (if applicable for drain wires)

  1. Perform Initial Safety Checks and Component Verification

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in high voltage electrical equipment safety. Inspect all parts for damage, rating, and compatibility with mating parts. Check the contents of the package to ensure completeness. Verify proper fit with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; if encountered, replace the damaged component. Have all required tools at hand and maintain cleanliness.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for ease of operation. Refer to the specific cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) in the full instructions for precise measurements and procedures for managing neutral/drain/shield wires and removing the outer jacket. Cut the cable squarely at the bushing centerline. Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor.

  3. Install the Compression Lug

    Wire brush the bare aluminum conductors thoroughly. Immediately install the compression lug onto the conductor, rotating it to spread the inhibitor. Position the compression lug so that the contact threaded hole aligns with the bushing bore. Refer to the crimp chart supplied with the lug for recommended crimp tool information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.

  4. Prepare Insulation and Assemble Elbow Housing

    Remove the insulation shield as shown in the cable cut-back diagram (typically 6-7/8 inches or 175mm from the lug end). Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor. Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole.

  5. Install the Probe and Ground the Elbow

    Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends. Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow and twist tightly. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect the Elbow to the Bushing Plug

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.