ABB Installation Products 262LR-B2220 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable…
UPC: 075114397711
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV, 200 Amp continuous rating with 25kA symmetrical momentary rating
- Integrated test point for safe voltage testing without de-energizing
- Accommodates 0.635" to 0.905" cable insulation diameters
- Compatible with #2 stranded/compressed or #1 solid/compact wire sizes
- Includes copper compression lug, probe, probe wrench, lubricant, and installation instructions
Specifications
Amperage Rating | 200 A |
Application | 25 kV, 200 Amp |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection Type | Compression |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Copper |
Material | Housing - EPDM-Rubber |
Series | 262LR |
Size | 9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter |
Size | 0.635-0.905 inch cable insulation diameter |
Size | 0.635 inch - 0.905 inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size |
Special Features | 28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-A-2220
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
161LR-C2250-SG3
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0. 200ECS-G3 Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
K656SR-J2270-SG3
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 kcmil. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K656SR-L2230-SG3
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size #1 AWG Stranded or Compressed. 1/0 AWG Solid or Compact. Copper Lug. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K655DLR-P0380
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700 to 750 kcmil or Compacted/Solid 900 kcmil.
K655LR-LAC02
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug with Cap, Stud, Shear Bolt Lug, Cable Adapter and lubricant. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size 3/0 AWG Stranded or Compressed or Solid or Compact to 500 kcmil Stranded or Compressed or Solid or Compact.Frequently Asked Questions
Does the product offer an optional integral jacket seal?
Yes, the enhanced design includes an optional integral jacket seal.
Is the enhanced elbow approved for rural infrastructure projects?
Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.
What standards and certifications does the product meet?
The enhanced Elastimold elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
How does the enhanced elbow reduce life cycle costs?
It is optimized for switching operations, provides lifetime ease of operation and non-stick performance with Elastimold bushings, and features an improved seal system.
What flexibility improvements does the enhanced design offer?
The enhanced design offers additional sizes, improved wider cable ranges, an easy order system, and an optional integral jacket seal.
What safety features are included in the enhanced elbow?
It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
What product is being enhanced by ABB?
The Elastimold 200 amp loadbreak elbow (15 kV and 25 kV series) has received an enhancement.
Is the enhanced elbow approved for rural infrastructure projects?
Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.
Does the product offer an optional integral jacket seal?
Yes, the enhanced design includes an optional integral jacket seal.
What standards and certifications does the product meet?
The enhanced Elastimold elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
How to Install the 262LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and initial connection of the 262LR Loadbreak Elbow Connector to various underground distribution cables and mating bushings.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Crimp Tool (for compression lug), Wire Brush, Wire Strippers/Cable Knife, Measuring Tape/Ruler, Hotstick
Supplies needed:
262LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Copper Wire (No. 14 AWG / 2.5mm), Neutral Wire Connector, Cleaning Solution/Wipes, HV Insulated Cap(s) or Connector(s)
- Perform Pre-Installation Checks and Safety Procedures
DANGER: DE-ENERGIZE ALL APPARATUS. Ensure the work area is clear. Inspect all components for damage, proper rating, and compatibility with mating parts. Check package contents for completeness. Verify probe threads freely into the compression lug for at least four turns. Read all instructions thoroughly and gather all required tools and supplies. Replace any protective shipping covers with appropriate HV insulated caps or connectors before proceeding.
- Prepare the Cable
Train the cable to ensure adequate slack for operation. Prepare neutral wires or grounding braid as required for your cable type, ensuring extra length for connection to tank ground. Cut the cable squarely at the bushing centerline. Remove the outer jacket and/or copper tape shield according to your cable type and specified dimensions (e.g., 9-5/8" jacket, 7-1/8" copper tape shield). Remove 2-1/8" (55mm) of the insulation shield and insulation from the cable end, cutting squarely without nicking the conductor. Bevel the insulation end 1/8" (5mm) maximum. Thoroughly clean the insulation to remove all dirt or inhibitor traces.
- Install the Compression Lug
Wire brush bare aluminum conductors immediately. Install the compression lug onto the conductor, rotating it to spread any inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug using the recommended crimp tool, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends, indicating proper torque.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.
- Connect the Elbow to the Bushing Plug
DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.