ABB Installation Products 262LR-A5230 25kV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter .575-.740…
UPC: 075114406109
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV rated, 200 Amp maximum current capacity
- Built-in test point for safe diagnostic testing without system de-energization
- Bi-Medal lug supports copper and aluminum conductors with 225A max amperage
- Accommodates cable insulation diameters from 0.575 to 0.740 inches
- Compatible with #1 AWG stranded compressed or 1/0 AWG compact/solid conductors
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 28kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Bi-Medal Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Series | 262LR |
Size | 9 inch x 8.2 inch |
Size | 9 in x 8.2 in |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.3200 L |
Package Weight (Metric) | 1.0520 kg |

262LR-E5230-SG2
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
K656SR-N0410
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.
262LRJS-D5230
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded - Compressed or 1/0 Compact - Solid Wire Size, Bi-Metal Compression Lug.
K656CETP-H0240-DRG
25kV, 600 Amp, Combo T Elbow Reducing Tap Plug with Test Point, includes Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter .850-1.050 inches (21.6-26.7 mm), Universal Aluminum Connector Type, Connector Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. With Insulating Cap.
K656CETP-P0410-DRG
25kV, 600 Amp, Combo T Elbow Reducing Tap Plug with Test Point, includes Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter 1.725-1.935 inches, Universal Aluminum Connector Type, Connector Size 1000 kcmil Stranded/Compressed. With Insulating Cap.
376LR-H5220
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1.
K655LR-G0330-SG3
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K655DLR-L0290
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 300 kcmil Stranded/Compressed or 350 kcmil Solid/Compact. Width 10.36 inch, Length 13 inch from bottom edge to Center of Bushing. Diameter 3.83 inch.Frequently Asked Questions
What is the maximum operating voltage for this loadbreak elbow?
The ABB 262LR-A5230 loadbreak elbow is rated for 25kV operating voltage.
What conductor sizes can be terminated with this elbow?
This elbow supports #1 AWG stranded compressed or 1/0 AWG compact/solid conductors.
Does this loadbreak elbow come with a sealing kit?
No, the ABB 262LR-A5230 model does not include a sealing kit.
What is the cable insulation diameter range for this elbow?
The elbow is designed for cable insulation diameters between .575 and .740 inches.
What type of lug is used for conductor connection?
This loadbreak elbow features a Bi-Medal lug for conductor termination.
How to Install Elastimold 261LR/262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 261LR and 262LR Loadbreak Elbow Connectors, covering initial checks, cable preparation, lug crimping, elbow assembly, grounding, and final connection to a de-energized bushing.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Crimp Tool, Wire Brush, Wire Strippers, Hotstick
Supplies needed:
Compression Lug, Probe, Lubricant (Do Not Substitute), Copper Ground Wire (No. 14 AWG / 2.5mm or equivalent), Grounding Connector, Cold Shrink Sealing Kit (if applicable)
- Perform Initial Safety and Component Checks
Before starting, ensure all apparatus in the work area are de-energized. This product must be installed only by competent personnel trained in high voltage electrical safety. Inspect all package contents for completeness and damage. Verify all components, including the compression lug and probe, fit properly with the cable and mating products. Check probe threads by hand-threading into the compression lug; replace if resistance is encountered.
- Prepare Cable and Outer Jacket
Train the cable to ensure sufficient slack for operation. Refer to the product manual for specific cable type instructions (e.g., non-jacketed, jacketed concentric neutral, drain wire, copper tape shield) to prepare neutral/grounding wires and remove the outer jacket to the specified length. Cut the cable squarely at the bushing centerline. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first.
- Prepare Conductor and Crimp Lug
Remove the insulation shield and insulation 2-1/8” (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the lug's instructions, starting at the crimp line mark and rotating 180 degrees for successive crimps. Carefully wipe excess inhibitor from the lug and cable. Remove the insulation shield as shown in the manual (6-7/8” (175mm) back from the cable end) and bevel the insulation end 1/8” (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble Elbow Housing and Probe
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect Grounding Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect Elbow to De-energized Bushing
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated 'hotstick' type tool; DO NOT OPERATE BY HAND. Ensure a fast, firm, straight motion to fully engage the elbow and bushing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.