Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656SR-N0410 - 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.

ABB Installation Products K656SR-N0410 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining…

UPC: 075114406482


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K656SR-N0410 is a 600 Amp, 15/25kV straight receptacle for medium-voltage cable connections. It includes a factory-installed cable adapter, aluminum compression lug, and retaining ring. Supports compressed stranded conductors sized at 1000 kcmil with insulation diameters from 1.515 to 1.780 inches. Part of ABB’s 600 Series, designed for reliable power distribution in industrial and utility applications. The aluminum compression lug ensures low-resistance electrical contact and long-term mechanical stability, while the retaining ring provides positive cable retention. The straight design simplifies installation in tight spaces or where axial alignment is required. Typical applications include switchgear, motor control centers, transformers, and other medium-voltage distribution equipment. The 600 Amp rating supports high-current circuits, and the 15/25kV insulation rating ensures compatibility with standard medium-voltage cable systems. The cable adapter accommodates the specified insulation diameter range. Meets industry standards for medium-voltage terminations and is suitable for indoor and outdoor environments when installed per ABB guidelines. SKU K656SR-N0410 is part of ABB’s Installation Products catalog.
  • 600 Amp, 15/25kV rated straight receptacle for medium-voltage applications
  • Includes cable adapter, aluminum compression lug, and retaining ring
  • Accommodates 1000 kcmil compressed stranded conductors
  • Cable insulation diameter range: 1.515" to 1.780"
  • Part of ABB’s 600 Series for medium-voltage power distribution

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Mounting Type
Straight Receptacle
Series
600 Series
Size
1.515 inch to 1.780 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655LINKCLRN0410ADRG

600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded - Compressed or 1/0 Compact - Solid Wire Size, Bi-Metal Compression Lug.

262LRJS-D5230

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded - Compressed or 1/0 Compact - Solid Wire Size, Bi-Metal Compression Lug.
25kV, 600 Amp, Combo T Elbow Reducing Tap Plug with Test Point, includes Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter .850-1.050 inches (21.6-26.7 mm), Universal Aluminum Connector Type, Connector Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. With Insulating Cap.

K656CETP-H0240-DRG

25kV, 600 Amp, Combo T Elbow Reducing Tap Plug with Test Point, includes Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter .850-1.050 inches (21.6-26.7 mm), Universal Aluminum Connector Type, Connector Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. With Insulating Cap.
25kV, 600 Amp, Combo T Elbow Reducing Tap Plug with Test Point, includes Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter 1.725-1.935 inches, Universal Aluminum Connector Type, Connector Size 1000 kcmil Stranded/Compressed. With Insulating Cap.

K656CETP-P0410-DRG

25kV, 600 Amp, Combo T Elbow Reducing Tap Plug with Test Point, includes Stud, Cable Adapter, Lug and Insulated Cap Kit, Cable Insulation Diameter 1.725-1.935 inches, Universal Aluminum Connector Type, Connector Size 1000 kcmil Stranded/Compressed. With Insulating Cap.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1.

376LR-H5220

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K655LR-G0330-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 300 kcmil Stranded/Compressed or 350 kcmil Solid/Compact. Width 10.36 inch, Length 13 inch from bottom edge to Center of Bushing. Diameter 3.83 inch.

K655DLR-L0290

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 300 kcmil Stranded/Compressed or 350 kcmil Solid/Compact. Width 10.36 inch, Length 13 inch from bottom edge to Center of Bushing. Diameter 3.83 inch.

How to Install K656SR and M656SR Straight Receptacle

This guide provides step-by-step instructions for installing the K656SR and M656SR straight receptacles, which enable an in-line cable connection to standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushings. Ensure all apparatus is de-energized before beginning installation to prevent serious injury.

Estimated time: 2h

Tools needed:

5/8-11 tap, Hex wrench, Torque wrench (with 15/16 socket), Wire strippers, Crimping tool

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant, Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire or equivalent, Suitable connector for neutral wires

  1. De-energize and Prepare Apparatus Bushing

    Before starting, ensure all apparatus is completely de-energized. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Train and Cut Cable

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  3. Manage Concentric Neutral Wires

    If applicable, unwrap the concentric neutral wires a distance of 30 inches (76 cm). Do not cut these wires. Bend and fold them back out of the way.

  4. Clean Cable Outer Jacket

    Wipe the outer jacket of the cable clean for a distance of 38 inches (96.5 cm) or up to the concentric neutral wires.

  5. Install Receptacle Housing

    Slide the receptacle housing onto the cable for a distance of 30 inches (76 cm).

  6. Prepare Cable Semi-con Shield

    Remove the semi-con shield and install a tape marker to the dimensions shown in the diagram (10-1/4 inches (26.04 cm) and 11-1/4 inches (28.58 cm) from the end). Do not cut or nick the cable insulation.

  7. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6 mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  8. Expose Cable Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4 3/4 inches to 5 inches (12.06 cm to 12.7 cm). If not, redo the assembly.

  9. Secure Holding Collar

    Position the aluminum holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew. The bare conductor length from the holding collar should be 4 3/8 inches to 4 3/4 inches (11.11 cm to 12.06 cm).

  10. Prepare and Position Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If this distance is over 7 inches (17.8 cm), do not proceed and redo all previous work.

  11. Verify Component Alignment

    Confirm that all components (Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter) are oriented in the correct order. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  12. Crimp the Connector

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If this distance is over 7 inches (17.8 cm), do not proceed and redo all previous work.

  13. Secure Connection Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. The splice and cables are now in their final positions. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  14. Lubricate Cable Adapter and Bushing Interface

    Generously apply the supplied lubricant or an ELASTIMOLD approved lubricant to the outside of the cable adapter and the area of the bushing adapter as shown in the diagram. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  15. Seat Receptacle Housing and Connect Ground

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, making a small loop and twisting tightly without damaging the eye. Gather the concentric neutral wires and, using a suitable connector, connect them with the grounding wire.

  16. (35kV Only) Secure Hose Clamp

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.