ABB - Installation Products 262LR-A5220 - 25kV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit.
More images

ABB Installation Products 262LR-A5220 25kV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter .575-.740…

UPC: 075114321846


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 262LR-A5220 is a 25kV, 200 Amp Loadbreak Elbow designed for safe, reliable cable connections in medium-voltage distribution systems. This elbow features a built-in test point for voltage verification without disconnecting the cable, enabling efficient maintenance and troubleshooting. The Bi-Medal Lug accommodates conductor sizes from #2 AWG stranded compressed to #1 AWG compact or solid, providing versatility for various cable configurations. The unit supports cable insulation diameters ranging from .575 to .740 inches, ensuring compatibility with standard medium-voltage cables. The product does not include a sealing kit and must be paired with compatible components for environmental protection. Key applications include: - Medium-voltage cable terminations in utility and industrial power distribution - Connections to pad-mounted transformers and switchgear - Underground distribution networks requiring loadbreak capability - Systems requiring hot-line switching for maintenance and reconfiguration The 262LR-A5220 is part of ABB's Installation Products line, designed for durability and reliability in demanding electrical environments. Its loadbreak design ensures safe operation under load, while the test point enables quick voltage verification without service interruption.
  • 25kV, 200 Amp Loadbreak Elbow with built-in test point for voltage verification
  • Bi-Medal Lug accepts #2 AWG stranded compressed or #1 AWG compact/solid conductors
  • Supports cable insulation diameters from .575 to .740 inches
  • Hot-line switching capability up to 200 Amps at 25kV
  • Compliant with ANSI C119.4 and IEEE 386 standards

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 28kV class, 200 Amp Distribution Apparatus
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection
Compression
Connection Type
Loadbreak Elbow
Connection Type
Loadbreak
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Medal Lug, Copper
Material
Bi-Medal Lug
Material
Housing - EPDM-Rubber
Series
262LR
Size
.575-.740 inches (cable insulation diameter)
Size
Cable Insulation Diameter .575-.740 inches, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid
Size
Cable Insulation Diameter .575-.740 inches
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.3200 L
Package Weight (Metric)
1.0520 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.

376LR-K2240

35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.
35kV, 600 Amps, Deadbreak Elbow with Test Point. Cable Insulation Diameter Range 1.515 to 1.780 inch, Aluminum Lug, Conductor Size 1000 Stranded/Compressed. No Sealing Kit.

756LR-N0410

35kV, 600 Amps, Deadbreak Elbow with Test Point. Cable Insulation Diameter Range 1.515 to 1.780 inch, Aluminum Lug, Conductor Size 1000 Stranded/Compressed. No Sealing Kit.
15/25kV, 200 Amp, Deadbreak Straight Plug without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal

K151SP-A0220-S

15/25kV, 200 Amp, Deadbreak Straight Plug without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Copper Lug. No Sealing Kit.

K655LR-L2330

15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Copper Lug. No Sealing Kit.
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal

K151SR-A0220-S

15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal

K151SR-B0250-S

15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Aluminum Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Spring Force.

K656LR-J0240-SG3

25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Aluminum Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Spring Force.

Frequently Asked Questions

Does this product have RUS acceptance?

Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.

What standards and certifications does the elbow meet?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the current rating of this loadbreak elbow?

The enhanced Elastimold loadbreak elbow has a current rating of 200 amps.

What voltage ratings does the loadbreak elbow support?

The enhanced Elastimold 200 amp loadbreak elbow supports 15 kV and 25 kV applications.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for switching operations.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for switching operations.

What voltage ratings does the loadbreak elbow support?

The enhanced Elastimold 200 amp loadbreak elbow supports 15 kV and 25 kV applications.

What is the current rating of this loadbreak elbow?

The enhanced Elastimold loadbreak elbow has a current rating of 200 amps.

What standards and certifications does the elbow meet?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

Does this product have RUS acceptance?

Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 262LR Loadbreak Elbow Connector, including cable preparation, assembly, and grounding procedures for various cable types.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Measuring tape, Wire strippers, Wire brush, Crimp tool, Probe wrench, Hotstick

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate neutral wire connector, Cleaning supplies, Cable sealing kit (if applicable)

  1. Perform Initial Checks and Safety Procedures

    Before starting, ensure all apparatus is de-energized. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Thread the probe into the compression lug to check for smooth operation. Have all required tools ready and maintain a clean work area. This product must be installed only by competent personnel trained in high-voltage safety practices.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for future operation. Prepare the concentric neutral wires or grounding braid wire as required by your specific cable type, ensuring extra length for connection to the tank ground. Cut the excess cable squarely at the bushing centerline. If using a cold shrink sealing kit, slide the tube onto the cable loose end first before proceeding.

  3. Prepare Cable End and Install Compression Lug

    Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors thoroughly. Immediately install the compression lug, rotating it to spread inhibitor, and align its threaded hole with the bushing bore. Crimp the lug according to the manufacturer's chart, rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield and bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Ground the Elbow Connector

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions for completion.

  6. Connect the Elbow to the Bushing Plug

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.