ABB Installation Products 376LR-K2240 35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 1.090 inch to…
UPC: 075114329095
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35 kV voltage rating for medium-voltage applications
- 200 A current rating for standard distribution feeders
- Copper compression lug for low-resistance, durable connections
- Test point for safe voltage verification without de-energizing
- Compatible with 1/0-2/0 AWG stranded/solid conductors, 1.090-1.310in insulation
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Push-In |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 1.090 inch to 1.310 inch |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

375LR-K-5240
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
756LR-N0410
35kV, 600 Amps, Deadbreak Elbow with Test Point. Cable Insulation Diameter Range 1.515 to 1.780 inch, Aluminum Lug, Conductor Size 1000 Stranded/Compressed. No Sealing Kit.
K151SP-A0220-S
15/25kV, 200 Amp, Deadbreak Straight Plug without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal
K655LR-L2330
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Copper Lug. No Sealing Kit.
K151SR-A0220-S
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal
K151SR-B0250-S
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal
K656LR-J0240-SG3
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Aluminum Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Spring Force.Frequently Asked Questions
Is the 376LR elbow suitable for submersible applications?
Yes, the 376LR features a fully shielded, fully submersible molded rubber housing.
What industry standard does the 376LR Loadbreak Elbow meet?
The 376LR Loadbreak Elbow meets ANSI/IEEE Standard 386, Latest Revision.
What items are included in the 376LR elbow connector kit?
The kit contains the elbow housing, a bi-metal compression lug, a probe, a probe wrench, lubricant, installation instructions, and a crimp chart.
What types of conductors are compatible with the compression lug?
The standard bi-metal compression lug is suitable for copper or aluminum conductors. Copper compression lugs are for copper conductors only.
What cable insulation diameters are compatible with the 376LR?
The 376LR connects cables with insulation diameters from .850 inches (21.6mm) to 1.465 inches (37.2mm).
Can the 376LR be operated with hot stick tools?
Yes, the 376LR includes provisions for energized operation using standard hot stick tools for loadmaking/loadbreak and visible disconnect.
Does the 376LR elbow include a voltage test point?
Yes, the 376LR elbow is equipped with an integral, non-corrosive capacitive voltage test point.
What is the impulse withstand rating of the 376LR?
The 376LR has a 150kV BIL impulse withstand rating, based on a 1.2 x 50 microsecond wave.
What is the maximum operating voltage for the 376LR?
The maximum phase-to-ground operating voltage for the 376LR is 21.1kV.
What is the voltage and current rating of the 376LR elbow?
The 376LR elbow is rated for 35kV voltage class and 200 Amp continuous and loadbreak current.
How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR and 376LR Loadbreak Elbow Connectors, including cable preparation, assembly, and connection to a 35kV class bushing.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Wire brush, Crimp tool, Hotstick, Wire strippers, Capacitive voltage tester (for 376LR)
Supplies needed:
Compression lug, Lubricant (do not substitute), No. 14 AWG / 2.5mm copper wire, Appropriate grounding connector, Silicone grease (for 376LR test point)
- Prepare for Installation and Safety Check
De-energize all apparatus before starting installation. Inspect all parts (Elbow Connector Housing, Compression Lug, Probe) for damage, proper rating, and compatibility with the cable and mating bushing. Check the package contents to ensure completeness. Thread the probe into the compression lug by hand to check for resistance; replace damaged components if resistance is encountered. Gather all required tools and supplies, and maintain cleanliness throughout the procedure.
- Prepare the Cable
Train the cable to ease operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut excess cable squarely at the center line of the bushing. Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off any excessive inhibitor. Remove the insulation shield as shown in the template and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten with a probe wrench until the wrench bends.
- Connect Concentric Neutral Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tight. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the neutral wires to allow for elbow operation.
- Connect Elbow to Bushing (De-energized)
WARNING: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY if both the transformer and elbow are known to be DE-ENERGIZED. Remove the insulated cap from the bushing using a hotstick. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT HOLD IN THE PARTIALLY INSERTED POSITION.
- Perform Voltage Test (376LR Only)
WARNING: This step can be performed energized, but treat the elbow as energized until confirmed otherwise. Remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Do not use conventional voltage measuring equipment. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.