
ABB Installation Products K151SR-A0220-S 15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation…
UPC: 075114331555
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV rated voltage for medium-voltage applications
- 200 Amp current rating with deadbreak functionality for safe load-side connections
- Accommodates 0.575" to 0.740" cable insulation diameters
- Compatible with #2 stranded/compressed or #1 solid/compact conductors
- Cold-shrinkable jacket seal (S) enables tool-free, heat-free installation
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection Type | Deadbreak Straight Receptacle |
Current Rating | 200 A |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Housing - EPDM-Rubber |
Material | Aluminum |
Size | Cable Insulation Diameter 0.575 to 0.740 inches |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656CY-J0220
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2 or Compacted Solid #1.
K151SR-B0250-S
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal
K656LR-J0240-SG3
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Aluminum Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Spring Force.
K655LR-J5300-SG3
15/25kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Bi-Metal Lug.
K675LR-N2420
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compact/Solid 1250.
162LR-B2230-SG3
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded/Compressed or 1/0 Solid/Compact Wire Size, Copper Compression Lug, Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
K655DLR-K0270-SG3
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.Frequently Asked Questions
What industry standard does the K151SR meet?
The K151SR meets ANSI/IEEE Standard 386, Latest Revision.
Does the K151SR have a provision for a ground wire connection?
Yes, the K151SR deadbreak straight receptacle includes a provision for a ground wire connection.
What components are included in a K151SR kit?
Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.
When can the disconnectible feature of the K151SR be used?
The disconnectible feature can be used only when the circuit is de-energized.
What cable insulation diameters are compatible with K151SR?
The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.
What conductor sizes does the K151SR accommodate?
The K151SR will accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What is the continuous current rating for this receptacle?
The K151SR receptacle has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What voltage systems is the K151SR suitable for?
The K151SR is suitable for use on both 15kV and 25kV systems.
What is the primary function of the K151SR receptacle?
The K151SR is a fully shielded, submersible connector designed to connect a cable to another cable or apparatus.
What is the primary function of the K151SR receptacle?
The K151SR is a fully shielded, submersible connector designed to connect a cable to another cable or apparatus.
How to Install the Elastimold 151SR/K151SR Straight Receptacle
This guide provides detailed instructions for installing the Elastimold 151SR/K151SR Straight Receptacle, including cable preparation, conductor crimping, and connection to a mating plug or apparatus. Ensure all apparatus is de-energized before starting.
Estimated time: 2h
Tools needed:
Wire strippers, Cable cutting tool, Wire brush, Crimp tool, Rag, Approved solvent
Supplies needed:
Elastimold 151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Supplied lubricant, Elastimold bail, Copper wire (#14 AWG or equivalent), Silicone grease, Protective cap (if not immediately connecting)
- De-energize Apparatus and Inspect Components
Before beginning, ensure all apparatus is de-energized. Verify that the package contents are complete and undamaged, and check all components for proper fit with the cable and/or mating products. Read all instructions thoroughly.
- Prepare Cable Jacket
For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, allowing sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7.5 inches from the end, then remove the copper tape shield 6.5 inches from the end. Follow specific instructions for ECS or MA grounding devices if applicable.
- Prepare Cable Insulation and Conductor
Remove 7/8 to 1 inch of cable insulation and conductive shield (1 3/4 to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable). Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel containing inhibitor.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp 90 degrees. For aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean Insulation
Remove the semi-conductive shield 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, ensuring not to cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and insulation thoroughly with an approved solvent, wiping from the cable end toward the outer jacket to remove all semi-conducting residue. Install ECS or MA grounding device if used.
- Lubricate and Insert Cable into Receptacle
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the diagram and to the inside of the housing. Do not substitute lubricants. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If not immediately connecting, replace with an appropriate HV insulated cap or connector, not just the shipping cover.
- Connect to Mating Plug (Optional)
To connect to a mating plug: Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring it is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an Elastimold bail.
- Ground the Cable
If an Elastimold grounding device is not used, connect a length of #14 AWG or equivalent copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.
