Authorized ABB Distributor (Installation Products)
ABB - Installation Products 756LR-L0280-SG3 - 15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 250 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

ABB Installation Products 756LR-L0280-SG3 15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and…

UPC: 075114322980


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-L0280-SG3 deadbreak elbow connector is rated for 15/25/35kV systems with a continuous current capacity of 600 amperes. Designed for 250 kcmil stranded compressed aluminum conductors, this elbow includes a test point for safe voltage verification without circuit interruption. The SG3 sealing kit provides a cold-shrinkable, copper-braided interface with constant force spring, ensuring reliable insulation for cable diameters between 1.180 and 1.465 inches. This deadbreak design allows for hot-stick operation, enabling safe connections and disconnections under load. The aluminum lug and included cable adapter simplify installation in medium-voltage distribution networks, switchgear, and pad-mounted transformers. Compatible with industry-standard 600A class equipment, this connector meets the demands of utility and industrial power systems where reliability and maintainability are critical.
  • Rated for 15/25/35kV systems with 600A continuous current
  • Fits 250 kcmil stranded compressed aluminum conductors
  • Includes test point for safe voltage verification
  • SG3 cold shrink sealing kit with copper braid and constant force spring
  • Compatible with cable insulation diameters 1.180-1.465 inches

Specifications

Amperage Rating
600 A
Application
15/25/35kV, 600 Amps
Color
Blue
Color
Black
Conductor Range
250 kcmil , 300 kcmil
Connection
Compression
Connection Type
Deadbreak Elbow
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
756LR
Size
Cable Insulation Diameter 1.180-1.465 inches
Special Features
SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Voltage Rating
15/25/35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

756LR-M0280

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.370-1.630 inches, Aluminum Lug, Conductor Size 500 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

756LR-M0330-SG3

15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.370-1.630 inches, Aluminum Lug, Conductor Size 500 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
25kV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit.

262LR-A5220

25kV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit.
35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.

376LR-K2240

35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.
35kV, 600 Amps, Deadbreak Elbow with Test Point. Cable Insulation Diameter Range 1.515 to 1.780 inch, Aluminum Lug, Conductor Size 1000 Stranded/Compressed. No Sealing Kit.

756LR-N0410

35kV, 600 Amps, Deadbreak Elbow with Test Point. Cable Insulation Diameter Range 1.515 to 1.780 inch, Aluminum Lug, Conductor Size 1000 Stranded/Compressed. No Sealing Kit.
15/25kV, 200 Amp, Deadbreak Straight Plug without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal

K151SP-A0220-S

15/25kV, 200 Amp, Deadbreak Straight Plug without Test Point, Cable Insulation Diameter 0.575 to 0.740 inches, Aluminum, Conductor Size 220 - #2 Stranded/Compressed or #1 Solid/Compact. S - Cold-Shrinkable Jacket Seal
15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Copper Lug. No Sealing Kit.

K655LR-L2330

15/25kV, 600 Amp, Deadbreak Elbow without Test Point. Cable Insulation Diameter Range 1.180 to 1.465 inch, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Copper Lug. No Sealing Kit.

Frequently Asked Questions

Does this elbow include a test point?

Yes, it features a test point for safe voltage verification without interrupting the circuit.

What is the current rating of this elbow?

The continuous current rating is 600 amperes.

What material is the lug made from?

The lug is made from aluminum.

What conductor size is compatible with this elbow?

It accommodates 250 kcmil stranded compressed aluminum conductors.

What is the cable insulation diameter range?

The elbow fits cables with insulation diameters between 1.180 and 1.465 inches.

What is the sealing kit used in this elbow?

The SG3 sealing kit is a cold-shrinkable design with copper braid and constant force spring.

Is this elbow suitable for hot-stick operation?

Yes, the deadbreak design allows for safe connections and disconnections under load using a hot stick.

How to Install 756/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR and 776LR deadbreak elbow connectors on 35kV class systems. These connectors provide fully shielded, submersible cable connections and allow for splicing or tapping 600-ampere or 900-ampere systems.

Estimated time: 1h 30m

Tools needed:

Cutting tool, Measuring tape, Wire brush, Crimping tool, Hotstick, Suitable sensing device

Supplies needed:

Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Threaded Stud, Wire (min. No. 14 AWG Copper), Suitable grounding connector, Waterproofing material, Protective caps

  1. Prepare Cable and Ensure Safety

    DANGER: De-energize all apparatus before installation. Do not touch or move energized products. This product must be installed by competent personnel trained in high voltage safety practices. Position the cable with enough slack for elbow removal. Cut the cable 1-3/4” (45mm) from the mating product centerline. Clean the outer jacket 24” (610mm). Inspect all parts for damage and compatibility. Prepare the cable by removing the outer jacket (if applicable) and preparing the cable insulation and shield according to the specific cable type (e.g., non-jacketed concentric neutral, jacketed shield wires, etc.) as detailed in the instructions.

  2. Install Cable Adapter and Crimp Lug

    Bevel the cable insulation end at a 45-degree angle, approximately 1/4” (6mm) back. Clean and lubricate the cable insulation towards the semi-con shield. Install the cable adapter, small end first, until flush with the tape marker. Remove protruding cable insulation, cutting it even with the cable adapter end. Ensure exposed conductor length is 4-3/8” to 4-3/4” (111mm-121mm). Fully insert the conductor into the compression lug (wire brush aluminum conductors first). Measure the 'Check Dimension' (less than 7” (178mm)). Crimp the lug per its instructions. Wipe excess inhibitor. Verify lug to adapter distance is 6-7/8” to 7-5/8” (175mm-194mm).

  3. Mount Elbow and Connect Mating Parts

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it stops, ensuring the adapter remains flush with the tape marker. Remove the tape marker. Remove protective caps from the elbow and mating part. Hand tighten the threaded stud (if needed) into the mating part. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. Clean and lubricate the mating part for the opposite end. Insert it into the elbow, engage threads, hand tighten, and torque per instructions.

  4. Ground and Test for Voltage

    If an insulating plug is used, clean and lubricate the inner surface of the voltage detection cap and snap it onto the elbow. Insert a wire (min. No. 14 AWG Copper) through the grounding eye, twist a loop, and connect to ground using a suitable connector. Ensure the cable shield is grounded. Waterproof the cable jacket to prevent moisture. To test for voltage, remove the test point cap with a hotstick (peel at an angle). Use a suitable sensing device for capacitive test points. WARNING: This is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Treat as energized until 'no voltage' is confirmed by other means. Clean, lubricate, and replace the cap after testing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.