ABB Installation Products 25PCJ1L1280 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 075114410618
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV Voltage Rating for medium voltage applications.
- Style 1 single-piece housing simplifies installation.
- Accommodates cable insulation diameters from 1.180" to 1.465".
- Designed for aluminum conductors: 250 kcmil stranded or 300 kcmil solid.
- Overall dimensions: 14 3/8" length (A) and 2 25/32" diameter (B).
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 250 STR kcmil , 300 SOL kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other severe service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

25PCJ1H (CTN)
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.
25PCJ2J1270-H1240
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. (A) Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 or Solid 250. (B) Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 or Solid 2/0.
15PCJ1-J1290-S
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded / Compressed 300 kcmil or Solid / Compact 350 kcmil. Installation Dies 470 251 980 83 B11CH CSA 26. Cold-Shrinkable Jacket Seal Included.
15PCJ2N2440
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size Stranded / Compressed 1250 kcmil.
25PCJ1L2310
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.
25PCJ1N1410
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Length 15-3/4 inch, Diameter 3-3/16 inch.
35PCJ1H1210
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3/ Compacted Solid #2.
25PCJ2H1240
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.Frequently Asked Questions
What conductor types are compatible with PCJ joints?
PCJ power cable joints can be used with both copper and aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.
What is the cable insulation diameter range for 25PCJ1L?
For 25PCJ1L, the cable insulation diameter ranges from 1.180 in minimum to 1.465 in maximum.
What conductor size does '280' represent for PCJ joints?
The conductor size code '280' represents 250 AWG or kcmil for both stranded/compressed and compressed/solid conductors.
What is the BIL impulse withstand for 25 kV class?
The BIL impulse withstand for the 25 kV class is 150 kV (1.2 x 50 μsec. wave).
What is the phase-to-ground voltage for 25 kV class?
For the 25 kV class, the phase-to-ground voltage is 14.4 kV.
What are the dimensions of a 25PCJ1LX joint?
A 25PCJ1LX joint has an overall length (Dimension A) of 14 3/8 in and an outside diameter (Dimension B) of 2 25/32 in.
Can copper connectors be used on aluminum conductors?
No, copper compression connectors are suitable for copper-to-copper connections only and must not be used on aluminum conductors.
What are Elastimold PCJ power cable joints?
Elastimold PCJ power cable joints use permanently crimped connectors inside EPDM rubber housings for reliable cable splicing. They offer options for straight or transition splicing of cables up to 1250 kcmil.
What voltage classes are available for PCJ joints?
PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What conductor size does '280' represent for PCJ joints?
The conductor size code '280' represents 250 AWG or kcmil for both stranded/compressed and compressed/solid conductors.
How to Install the 15/25/35PCJ1 Series Straight Joint
This guide provides detailed instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible joint for connecting wire shielded cables. It covers essential cable preparation, splice installation, and final assembly steps.
Estimated time: 4h
Tools needed:
Cable stripping tools, Measuring tape, Wire brush (for aluminum conductors), Crimping tool, Deburring tool or file, T&B WT3D tool (for 35kV applications)
Supplies needed:
Joint Housing (included), Splice (Conductor Contact) (included), Lubricant (DO NOT SUBSTITUTE) (included), Conductor connector (user supplied), Grounding wire (#14 AWG copper or equivalent, if needed), DELTECt Cable ties TYD5135 (for 35kV only), Appropriate connector (for grounding wires), Cleaning supplies
- Ensure Safety and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents for completeness and damage. Verify all components for proper fit with the cable and/or mating products before proceeding.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint. This ensures sufficient length of shield wires for rejoining over the completed joint.
- Remove Cable Jackets
Where applicable, remove the cable jacket of Cable 1 to a length of 37 inches (940mm) and the cable jacket of Cable 2 to a length of 21 inches (530mm) from the joint centerline.
- Fold Back Shield Wires and Cut Cables
Carefully fold back the shield wires on both cables. Then, cut both cables precisely at the centerline of the joint.
- Prepare Cable 1 and Store Joint Housing
Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, pushing it up to the shield wires for temporary storage.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both cables according to the dimensions 'X' and 'Y' provided in the documentation for your specific conductor size. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.
- Install the Splice
If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert the conductors into the splice and check the dimension against the 'Max Check Before' table in the documentation. If it exceeds the maximum, redo the assembly. Crimp the splice following the recommendations provided with the splice itself.
- Clean and Deburr Splice Area
Wipe off any excess inhibitor from the splice. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds the maximum, redo the assembly. Remove any sharp protrusions or burrs generated during crimping. Ensure all metal chips or filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to create a lubricant ramp at the edge of the insulation shield.
- Slide Housing into Final Position
Carefully slide the joint housing into its final position over the splice. Proper positioning is achieved by observing and equalizing the deformation of the joint ends, which is caused by the underlying cable insulation shield.
- Install 35kV Cable Ties (If Applicable)
For 35kV installations ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance. Install the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first, ensuring an offset of the locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.
- Retrain and Connect Shield Wires
Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector.
- Reconstruct Cable Jacket
Where applicable, reconstruct the cable jacket over both cables and the joint housing to complete the installation.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.