Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1N1410 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Length 15-3/4 inch, Diameter 3-3/16 inch.

ABB Installation Products 25PCJ1N1410 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 075114427371


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 25kV Power Cable Joint (SKU: 25PCJ1N1410) is a single-piece housing joint designed for medium-voltage power cable systems. This joint accommodates aluminum conductors with a stranded size of 1000 AWG and supports cable insulation diameters ranging from 1.515 to 1.780 inches. The unit measures 15-3/4 inches in length and 3-3/16 inches in diameter, providing a compact yet robust solution for field installations. Engineered for 25kV class applications, this joint ensures reliable electrical continuity and mechanical integrity in underground and aerial power distribution systems. The single-piece housing simplifies installation by reducing assembly steps while maintaining environmental protection against moisture, contaminants, and mechanical stress. The aluminum conductor compatibility aligns with common utility-grade cable designs, offering compatibility with existing infrastructure. Typical applications include utility substations, industrial power feeds, commercial distribution networks, and renewable energy interconnections where medium-voltage cable joints are required. The joint’s dimensions and voltage rating make it suitable for both new installations and maintenance operations in constrained spaces. ABB’s design leverages field-proven materials and construction to deliver consistent performance in harsh operating conditions, including temperature fluctuations and exposure to UV radiation. For specifiers and installers, this joint provides a standardized solution that meets utility-grade requirements while minimizing installation time. The 1000 AWG conductor size supports high current-carrying capacity, and the 25kV rating ensures compliance with common medium-voltage distribution standards. Order with confidence using SKU 25PCJ1N1410 for a dependable cable joint solution.
  • Voltage rating: 25 kV for medium-voltage applications
  • Conductor: 1000 AWG stranded aluminum
  • Insulation diameter range: 1.515" to 1.780"
  • Dimensions: 15-3/4" length, 3-3/16" diameter
  • Single-piece housing for simplified installation

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
Length 15-3/4 in , Diameter 3-3/16 in
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other severe service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.

25PCJ1N1410-0MA

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3/ Compacted Solid #2.

35PCJ1H1210

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3/ Compacted Solid #2.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 250 - 2/0 Stranded, Compressed or 3/0 Compact. Solid

25PCJ2H2250

25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 250 - 2/0 Stranded, Compressed or 3/0 Compact. Solid
25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 280 - 250 kcmil Stranded/Compressed.

25PCJ2H2280

25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 280 - 250 kcmil Stranded/Compressed.
15kV, Power Cable Joint with SG3 - Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter K - 1.090 to 1.310 inch. Copper Compression Lug, Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

15PCJ1K2330-SG3

15kV, Power Cable Joint with SG3 - Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter K - 1.090 to 1.310 inch. Copper Compression Lug, Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1 or Solid 1/0. Overall Length 14-3/8 inch, Diameter 2-25/32 inch.

25PCJ1L1230

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1 or Solid 1/0. Overall Length 14-3/8 inch, Diameter 2-25/32 inch.
69kV Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style - 1, Insulation Diameter Range R - 2.20 to 2.58 inch, Aluminum Connector, Connector Code 40P - 1.036 to 1.100 inch, Bore Size 1.125, Type Shield - Copper Tape, Metallic Screen Continuity Kit - 4/0 Welding cable, 6 Foot Quantity 4 but 1 without Split Bolts, Outer Jacket Restoration Kit - Heat Sink.

69TCJS1R140PVAGNB

69kV Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style - 1, Insulation Diameter Range R - 2.20 to 2.58 inch, Aluminum Connector, Connector Code 40P - 1.036 to 1.100 inch, Bore Size 1.125, Type Shield - Copper Tape, Metallic Screen Continuity Kit - 4/0 Welding cable, 6 Foot Quantity 4 but 1 without Split Bolts, Outer Jacket Restoration Kit - Heat Sink.

Frequently Asked Questions

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

Can aluminum connectors be used for copper-to-copper connections?

No, an all-copper connector is required for copper-to-copper connections. Aluminum compression connectors are suitable for aluminum-to-aluminum or aluminum-to-copper.

What is the short-time current rating for PCJ power cable joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating for PCJ power cable joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What conductor materials are compatible with PCJ cable joints?

PCJ power cable joints can be used with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil. They provide a permanent, fully shielded, fully submersible splice.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What voltage classes are PCJ power cable joints available in?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What types of installations are suitable for PCJ cable joints?

PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications. They provide a fully submersible splice.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for wire shielded cables, connecting aluminum to aluminum or aluminum to copper conductors. Ensure all apparatus are de-energized during installation to prevent serious injury or fatality.

Estimated time: 2h

Tools needed:

Cable strippers/knives, Wire brush, Crimping tool, Measuring tape, T&B WT3D tool (for 35kV installations)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), DELTECt Cable ties (for 35kV installations), #14 AWG copper wire or equivalent (for grounding, if needed), Appropriate connector (for grounding wires)

  1. Prepare Cables for Jointing

    DANGER: All apparatus must be de-energized. Overlap both cables and cut them to 12 inches (305mm) from the joint's center line. Remove the cable jacket from Cable 1 to 37 inches (940mm) and from Cable 2 to 21 inches (530mm), where applicable. Fold back the shield wires on both cables. Cut both cables precisely at the joint's center line.

  2. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation shield from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it back until it rests against the folded-back shield wires.

  3. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. For 500-750 MCM, expose 2 1/2 inches (64mm) of conductor and remove 6 1/4 inches (159mm) of insulation shield. For 1000 MCM, expose 2 3/8 inches (68mm) of conductor and remove 6 3/8 inches (162mm) of insulation shield.

  4. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the conductor insertion depth: for 500-750 MCM, max 6 inches (152mm); for 1000 MCM, max 6 7/8 inches (156mm). If exceeded, re-do assembly. Crimp the splice securely following its recommendations. Wipe off excess inhibitor. Measure the distance between cable insulations: for 500-750 MCM, max 6 1/4 inches (159mm); for 1000 MCM, max 6 1/2 inches (165mm). If exceeded, re-do assembly.

  5. Clean and Lubricate for Housing

    Remove any sharp protrusions or burrs created during crimping. Thoroughly clean the splice and surrounding joint assembly area to remove all metal chips or filings before sliding the joint housing. Clean the cables as indicated in the diagram. Apply lubricant in the direction of the arrows, creating a build-up or ramp of lubricant at the edge of the insulation shield.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position over the splice, ensuring proper positioning by equalizing deformation at both ends. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, 1/4 inch (6mm) apart with offset locking heads (T&B WT3D tool recommended). Remove the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the joint ends. Insert one shield wire from each cable (if #14 AWG or larger) through the joint grounding eye; use #14 AWG copper wire if smaller. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.