ABB - Installation Products 25PCJ1L2310 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.

ABB Installation Products 25PCJ1L2310 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786554188


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 25kV Power Cable Joint, SKU 25PCJ1L2310, is designed for reliable splicing of copper conductor power cables. It features a Style 1 configuration with a single-piece housing, simplifying installation and ensuring a secure connection. The joint accommodates cable insulation diameters ranging from 1.180 inches to 1.465 inches, making it suitable for a specific range of cable sizes. Specifically, it is engineered for use with 500 AWG solid copper conductors. The 25kV rating signifies its capability for medium-voltage power distribution applications. This product is part of ABB's Installation Products catalog, known for its electrical infrastructure solutions. The robust construction of the single-piece housing provides mechanical protection and environmental sealing for the splice. This joint is a critical component for maintaining the integrity and operational continuity of medium-voltage power systems. Its precise fit for the specified insulation diameter range ensures proper electrical insulation and stress control at the joint. Key Specifications: - Manufacturer: ABB - Installation Products - SKU: 25PCJ1L2310 - Voltage Rating: 25kV - Cable Insulation Diameter Range: 1.180" - 1.465" - Conductor Type: Copper - Conductor Size: 500 AWG Solid - Joint Style: Style 1 - Housing: Single Piece
  • 25kV voltage rating for medium-voltage applications
  • Style 1 joint with single-piece housing for straightforward installation
  • Accommodates cable insulation diameters from 1.180" to 1.465"
  • Designed for 500 AWG solid copper conductors
  • ABB Installation Products quality and reliability

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.

25PCJ1H (CTN)

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Length 15-3/4 inch, Diameter 3-3/16 inch.

25PCJ1N1410

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Length 15-3/4 inch, Diameter 3-3/16 inch.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3/ Compacted Solid #2.

35PCJ1H1210

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3/ Compacted Solid #2.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 250 - 2/0 Stranded, Compressed or 3/0 Compact. Solid

25PCJ2H2250

25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 250 - 2/0 Stranded, Compressed or 3/0 Compact. Solid
25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 280 - 250 kcmil Stranded/Compressed.

25PCJ2H2280

25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 280 - 250 kcmil Stranded/Compressed.
15kV, Power Cable Joint with SG3 - Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter K - 1.090 to 1.310 inch. Copper Compression Lug, Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

15PCJ1K2330-SG3

15kV, Power Cable Joint with SG3 - Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter K - 1.090 to 1.310 inch. Copper Compression Lug, Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1 or Solid 1/0. Overall Length 14-3/8 inch, Diameter 2-25/32 inch.

25PCJ1L1230

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1 or Solid 1/0. Overall Length 14-3/8 inch, Diameter 2-25/32 inch.

Frequently Asked Questions

What standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are for copper-to-copper connections only. Do not use them on aluminum conductors.

When should I use an aluminum compression connector?

Aluminum compression connectors are suitable for splicing aluminum-to-aluminum or aluminum-to-copper conductors.

What is the phase-to-ground voltage for each class?

It is 8.7 kV for 15 kV class, 14.4 kV for 25 kV class, and 20.2 kV for 35 kV class.

What is the short-time current rating of PCJ joints?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What safety features do PCJ joints provide?

A molded conductive shield provides a virtually unbreakable ground shield for dead-front construction. A grounding eye connects to the ground wire.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 uses separate cable adapters for transition splicing between different cable sizes.

What types of cable splicing do PCJ joints support?

PCJ power cable joints support straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil.

Where can PCJ power cable joints be installed?

They can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, and submersible splice.

How to Install the 25PCJ1 Series Straight Joint

This guide provides step-by-step instructions for installing the 15/25/35PCJ1 series permanent, fully shielded, and submersible straight joint for wire shielded cables, connecting aluminum to aluminum or aluminum to copper conductors.

Estimated time: 2h

Tools needed:

Wire brush, Crimping tool, Cable stripping tools, Measuring tape, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing (included), Splice (Conductor Contact) (included), Lubricant (DO NOT SUBSTITUTE, included), Electrical connector (user supplied), DELTEC Cable ties (TYD5135, for 35kV only), #14 AWG copper wire (or equivalent, if needed)

  1. Ensure Safety and Inspect Components

    Before beginning, ensure all apparatus in the work area are de-energized to prevent serious or fatal injury. Do not touch or move energized products. Inspect all package contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Gather all required tools and maintain cleanliness throughout the procedure.

  2. Prepare Cables for Joint Centerline

    Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint, ensuring sufficient length for shield wires to rejoin. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Finally, cut both cables precisely at the joint centerline.

  3. Prepare Cable 1 and Position Joint Housing

    Taper the edge of Cable 1's insulation from at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the dimensions 'X' and 'Y' provided in the diagram (e.g., 2 1/2 inches for 500-750 MCM, 2 3/8 inches for 1000 MCM for 'Y'; 6 1/4 inches for 500-750 MCM, 6 3/8 inches for 1000 MCM for 'X'). Then, carefully remove the insulation shield from both cables. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.

  5. Install and Crimp the Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table (e.g., 6 inches for 500-750 MCM, 6 7/8 inches for 1000 MCM); if it exceeds this, redo the assembly. Crimp the splice securely, following the recommendations provided with the splice. Wipe off any excess inhibitor. Check the distance between the cable insulations against the 'Max Check After' table (e.g., 6 1/4 inches for 500-750 MCM, 6 1/2 inches for 1000 MCM); if it exceeds this, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area.

  6. Lubricate Cables for Housing Slide

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows, ensuring a build-up or ramp of lubricant at the edge of the insulation shield on both sides of the splice. This lubrication facilitates the final positioning of the joint housing.

  7. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTEC Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice and then 1/4 inch (6mm) from the first, with offset locking heads. Use a T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate user-supplied connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.