ABB Installation Products 252LR-E2120-G 12/20kV (24 kV), IEC 250 Amp, Deadbreak Elbow Connector with Test Point, Cable…
UPC: 075114392181
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 24kV (20kV rated) deadbreak elbow connector for medium-voltage cable terminations
- Supports cable insulation diameters from 1.09 to 1.31 inches (27.48-33.27mm)
- Accommodates 120mm² copper conductors with included copper lug
- Includes test point probe for safe voltage verification during installation and operation
- Compact dimensions (5.454 x 7.531 inches, 2.097-inch diameter) for installation in tight spaces
Specifications
Amperage Rating | 250 A |
Application | 15/25kV, 250 Amp Deadbreak Connector |
Color | Black |
Conductor Range | 120 mm2 |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 7.531 in |
Length | 191.2874 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point. Includes Bonding/Grounding Wire |
Standard | IEC 60502-4, CEN 629.1 S2 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Width | 5.454 in |
Width | 138.5316 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

252LR-D2120
12/20 (24) kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 22.61mm - 30.99mm, Copper Compression Lug, Conductor Size 120mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
252LR-E2095-G
12/20kV (24 kV), IEC 250 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27mm), Copper Lug, Conductor Size 95 mm2. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Standard Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Includes Bonding/Grounding Wire. IEC 60502-4, CEN 629.1 S2.
262LR-B2230
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #1 Stranded/Compressed or 1/0 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.
261LR-D2250
25/28kV, Load Break,200 Amp Elbow without Test Point, No Sealing Kit. .890 inch - 1.220 inch Cable Insulation Diameter. Wire Size 2/0 Stranded/Compressed, 3/0 Solid/Compact, 67.43 mm2. Copper Compression Lug. ANSI/IEEE Standard 386. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart, Installation Instructions.
162LR-A-5210-S
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3, Solid #2, 26.67 mm2. 200ECS Jacket Seal Included. ANSI/IEEE Standard 386. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Lubricant, V.D Cap-Peroxide, Crimp Chart, Installation Instructions.
K656LR-E0240
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.530 inch to 0.680 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. No Sealing Kit. Includes Elow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions, Crimp Chart.
M465LR-G2240
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 0.760 to 0.95 inch, Copper Lug, Wire Range 1/0 Stranded/Compressed or 2/0 Solid Compact. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
162LRJSC5270-CS782C
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 inch Cable Insulation Diameter. Wire Size 1/0 Stranded/Compressed, 2/0 Solid/Compact, 53.49 mm2. Bi-Metal Compression Lug. ANSI/IEEE Standard 386. Includes Elbow Connector Housing, Compression Lug, Probe, Lubricant, V.D Cap-Peroxide, Butyl Auto Tape, Contact Adapter Ring, Crimp Chart, Installation Instructions. Boxed Individually.Frequently Asked Questions
Does this connector include a test point?
Yes, the kit includes a test point probe for voltage verification.
What is the current rating of this connector?
The connector has a 250A current rating.
Is a bonding/grounding wire included with this connector?
Yes, the kit includes a bonding/grounding wire for safety compliance.
What voltage rating does the 252LR-E2120-G support?
The connector is rated for 24kV (20kV nominal) and meets IEC 60502-4 standards.
What conductor size is compatible with this connector?
The 252LR-E2120-G supports 120mm² copper conductors.
What cable insulation diameter range does this connector accommodate?
The connector supports cable insulation diameters from 1.09 to 1.31 inches (27.48–33.27mm).
What are the dimensions of the 252LR-E2120-G connector?
The connector measures 5.454 x 7.531 inches with a 2.097-inch diameter.
What standards does this connector comply with?
The connector is certified to IEC 60502-4 and CEN 629.1 S2 standards.
How to Install the 252LR Deadbreak Elbow Connector
This guide provides step-by-step instructions for installing the 252LR Deadbreak Elbow Connector, including initial safety checks, cable preparation, elbow assembly, neutral connection, and final connection to a deadbreak bushing or accessory device.
Tools needed:
Wrench, Hotstick, Wire brush, Crimp tool, Wire strippers, Measuring tape, Voltage sensing device
Supplies needed:
Lubricant, Hold-down Bail, No. 14 AWG (2.5mm) Copper wire, Appropriate connector for neutral wires, Vinyl tape (if applicable), Conductive copper tape (if applicable), Cold shrink tube (if applicable), HV insulated cap(s) or connector(s) (if replacing shipping covers)
- Perform Initial Safety and Part Inspection
DANGER: De-energize all apparatus during installation or removal. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility with mating parts. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Failure to follow instructions will result in damage and serious or fatal injury.
- Conduct Pre-Installation Checks
Read the entire installation instruction before starting. Check the contents of the package to ensure they are complete and undamaged. Check the elbow housing cable entrance size and compression lug size for proper fit with the cable. Check threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component. Ensure the unit will be bailed. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare Non-Jacketed Concentric Neutral Cable
Train cable to ensure slack for ease of operation. Pull extra cable to 24-26 inches (610-660mm) beyond the centerline of the bushing. Bind neutrals 7 3/4 to 8 inches (195-203mm) further back from the center of the bushing. Connect neutral wires to the tank ground with a jumper or braid. Unwrap the neutral wire to the binding. Cut excess cable squarely at the centerline of the bushing.
- Prepare Jacketed Concentric Neutral Cable
Train cable to ensure slack for ease of operation. Pull extra cable to 24-26 inches (610-660mm) beyond the centerline of the bushing. Place a tape mark at the centerline of the bushing. Remove the outer jacket 9 5/8 inches (240mm) further back from the tape mark. Connect neutral wires to the tank ground with a jumper or braid. Unwrap the neutral wire back past the bushing centerline. Cut excess cable squarely at the centerline of the bushing. If using a 200ECS sealing kit, slide the cold shrink tube onto the cable beginning at the loose end.
- Prepare Jacketed Cable with Drain Wires
Cut the cable squarely at the centerline of the bushing. Remove 9-5/8 inches (240mm) of the outer jacket. Unwrap the ground wires, DO NOT CUT OFF, bind and fold them back out of the way. Wrap a piece of vinyl tape around the cable covering the wire ends. If using a 200ECS-G1 sealing kit, slide the cold shrink tube onto the cable beginning at the loose end.
- Prepare Jacketed Copper Tape Shield Cable
Cut the cable squarely at the centerline of the bushing. Remove 9-5/8 inches (240mm) of the outer jacket. Remove 7-1/8 inches (180mm) of the copper tape shield. Wrap conductive copper tape, included with the 200ECS-G2 kit, over the end of the copper shield to hold it in place. If using a 200ECS-G2 kit, slide the cold shrink tube onto the cable, loose end first.
- Complete Cable Preparation
Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately place the compression lug over the bushing, rotating to spread inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable. Remove the insulation shield as shown (6-7/8 inches (175mm) from cable end). Bevel the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Housing
Clean the cable insulation and the inside of the elbow housing, then lubricate with the supplied lubricant. DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable with a back and forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten the probe with a wrench until the wrench bends.
- Assemble the Hold-down Bail
Place the hold-down bail in the hold-down bracket.
- Connect the Concentric Neutral
Using a separate copper wire (No. 14 AWG / 2.5mm), insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing Plug
Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate only if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow on the bushing. DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.
- Secure Elbow with Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow.
- Perform Voltage Test (Optional)
WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Remove the test point cap with a hotstick, peeling off at an angle. Test with a suitable sensing device made for use with separable connectors with capacitive test points to determine if the cable is energized. Contamination or wrong equipment can provide a false “no voltage” indication. Treat the elbow as energized until “no voltage” is confirmed by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.
