ABB Installation Products 252LR-B2025 12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable…
UPC: 075114373531
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 24kV, 250 Amp rating for medium-voltage applications
- Designed for cable insulation diameters: 16.13 mm - 22.90 mm
- Accommodates 25mm conductor size with copper compression lug
- Features a test point for safe electrical testing
- IEC Standard compliant, includes housing, lug, probe, and accessories
Specifications
Amperage Rating | 250 A |
Application | 12/20 (24) kV |
Color | Blue |
Color | Black |
Conductor Range | 25 mm |
Connection | Compression |
Connection Type | Deadbreak, Compression Lug |
Current Rating | 250 A |
Environmental Conditions | Harsh Conditions |
Insulation | True |
Material | Copper, Poly |
Material | Housing - EPDM-Rubber |
Series | 252LR |
Size | Cable Insulation Diameter 16.13 mm - 22.90 mm, Conductor Size 25 mm |
Special Features | Robust Stainless Steel Pulling Eye. Dual Grounding Eye Positions. Designed to Remain Fully Operational in Harsh Conditions |
Standard | IEC 60502-4, CEN 629.1 S2 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 24 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

252LR-B2025-S
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 25mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
252LR-B2035
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 35mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
252LR-B2050-S
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Sealing Kit, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 50mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
252LR-C2095-S
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Sealing Kit, Cable Insulation Diameter - 20.45 mm - 26.92 mm, Copper Compression Lug, Conductor Size 95mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
252LRJS-B2025
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - 16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 25mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
252LR-C2070-S
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Sealing Kit, Cable Insulation Diameter - 20.45 mm - 26.92 mm, Copper Compression Lug, Conductor Size 70mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.Frequently Asked Questions
What items are included in each connector kit?
Each kit includes an elbow connector housing, copper lug, probe, probe wrench, standard bail assembly, lubricant, installation instructions, crimp chart, and a V.D. cap-peroxide.
What conductor sizes are available for copper lugs?
Copper lugs are available for conductor sizes including 25, 35, 50, 70, 95, and 120 mm2. These lugs are suitable for all copper conductors.
What is the voltage rating of the connector?
The Elastimold IEC 250 amp deadbreak elbow connector is rated for 12/20 (24) kV.
What industry standards does this connector meet?
The connector meets IEC 60502-4 and CEN 629.1 S2 standards. It has been tested and certified by KEMA.
What conductor sizes are available for copper lugs?
Copper lugs are available for conductor sizes including 25, 35, 50, 70, 95, and 120 mm2. These lugs are suitable for all copper conductors.
What items are included in each connector kit?
Each kit includes an elbow connector housing, copper lug, probe, probe wrench, standard bail assembly, lubricant, installation instructions, crimp chart, and a V.D. cap-peroxide.
What industry standards does this connector meet?
The connector meets IEC 60502-4 and CEN 629.1 S2 standards. It has been tested and certified by KEMA.
What is the voltage rating of the connector?
The Elastimold IEC 250 amp deadbreak elbow connector is rated for 12/20 (24) kV.
What if my cable insulation OD is less than 14.61 mm?
If the insulation OD is lower than 14.61 mm, use cable adapter 160CA-W, where "W" indicates the insulation OD range.
What items are included in the connector kit?
Each kit contains an elbow connector housing, copper lug, probe, probe wrench, standard bail assembly, lubricant, installation instructions, crimp chart, and a V.D. cap-peroxide.
How to Install the 252LR Deadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and connection of the 252LR Deadbreak Elbow Connector to UD jacketed or non-jacketed cables and a deadbreak bushing.
Estimated time: 1h
Tools needed:
Wrench, Hot stick, Wire brush, Crimp tool, Wire strippers, Capacitive voltage sensing device
Supplies needed:
252LR Deadbreak Elbow Connector kit (housing, lug, probe, lubricant, bail), UD jacketed or non-jacketed cable, Jumper or grounding braid, No. 14 AWG (2.5mm) copper wire, Appropriate wire connector, Vinyl tape (optional, for drain wires), Cold shrink tube (optional, for sealing kits), Conductive copper tape (optional, for tape shield kits), HV insulated cap(s) or connector(s) (if shipping covers are removed)
- Perform Pre-Installation Checks and Safety Review
Read all installation instructions thoroughly before starting. Inspect all parts for any damage, verify their rating, and ensure compatibility with mating components. Check the elbow housing and compression lug sizes to ensure a proper fit with your cable. Test the probe threads by hand-threading into the compression lug; if resistance is encountered, check for damage and replace the component. Ensure all apparatus are de-energized during installation. Have all required tools ready and maintain cleanliness throughout the procedure.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack for ease of operation. Prepare the cable's neutral wires, grounding braid, or copper tape shield according to the specific cable type (e.g., non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield). This involves removing the outer jacket/shield to specific lengths and binding or folding wires as required. Cut the excess cable squarely at the centerline of the bushing. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable.
- Prepare Cable Insulation and Install Compression Lug
Remove 2-1/8” (55mm) of the cable shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately place the compression lug over the bushing, rotating it to spread the inhibitor. Position the compression lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the diagram (6-7/8” / 175mm from the lug end). Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Clean the cable insulation and the inside of the elbow housing. Lubricate both surfaces with the lubricant supplied in the kit; do not substitute other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten the probe with the wrench until the wrench bends.
- Connect the Concentric Neutral Wires
Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist it tightly, ensuring not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation.
- Connect the Elbow to the Bushing Plug
Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate these surfaces with the supplied lubricant. WARNING: Only lubricate if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. WARNING: Do not operate by hand. Do not separate if energized.
- Secure the Elbow with the Hold-Down Bail
Pull the hold-down bail up over the crown (top) of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten the eyebolt by turning it in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow. Once the nut is in its final position, it will not need to be readjusted when removing and replacing the elbow.
- Perform Voltage Test (Optional but Recommended)
Remove the test point cap with a hot stick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable capacitive sensing device made for use with separable connectors and follow its manufacturer's directions. WARNING: Contamination, moisture, dirt, or incorrect equipment can provide a false “no voltage” indication on an energized elbow. Treat the elbow as energized until the “no voltage” test point indication is confirmed by other means to prevent serious or fatal injury. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.