ABB Installation Products 168RLR-F5240 15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation…
UPC: 783786318742
Contact for Pricing
Minimum Qty: 8
Multiplier: 8
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating
- 200 Amp continuous current rating
- Test point for diagnostics
- Accommodates 0.640" to 0.820" cable insulation diameter
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection Type | Loadbreak Replacement Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 168RLR |
Size | Cable Insulation Diameter 0.640 inch to 0.820 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 4.2800 L |
Package Weight (Metric) | 1.9410 kg |

K655LR-H0240
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
376LR-K-5260
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
168RLR-F-5250
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-F-5200
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
168RLR-H-5260
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
274RLR-G-5220
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
K675LR-N5380-SG3
15-25 Kv Elbow Connector, 900 Amps, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
755LR-N0400
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.Frequently Asked Questions
What is the current rating of the elbow connectors?
The elbow connectors are rated for 200 A loadbreak applications.
What voltage classes do these connectors support?
The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.
How much length does the repair elbow add?
The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.
How much length does the replacement elbow add?
The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.
What material are the elbows constructed from?
The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
Are these elbow connectors certified?
Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
Where are Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.
What is the test point cap catalog number?
The test point cap catalog number for elbows with a test point is 156-7.
How much length does the repair elbow add?
The repair elbow provides a net gain of 3 1/4 inches in length compared to a standard elbow.
What cable insulation diameters are supported by 167/168RLR?
For 167/168RLR models, supported cable insulation diameters range from 0.640 inches to 1.310 inches.
How to Install the 168RLR Loadbreak Replacement Elbow Connector
This guide details the installation of the 168RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable with concentric neutral and extruded insulation shielding. It provides an operating interface for 15kV class loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Cable cutter, Cable insulation stripper, Wire brush, Crimping tool, Probe wrench, Wire strippers, Screwdriver, Hotstick, Suitable sensing device for capacitive test points
Supplies needed:
Replacement Elbow Connector Housing (168RLR), Compression Lug (with inhibitor), Probe, Lubricant (supplied, do not substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral wires), Silicone grease (for test point cap)
- Safety First and Pre-Installation Checks
Before starting any work, ensure all apparatus is de-energized to prevent serious or fatal injury. This product must only be installed by competent personnel trained in high voltage safety practices. Perform pre-installation checks: verify package contents are complete and undamaged, ensure components fit correctly with the cable and mating products, and check the probe threads by hand-threading into the compression lug for smooth operation. Have all required tools ready and maintain cleanliness throughout the procedure.
- Remove Existing Livefront Termination
Begin by safely removing the existing livefront termination. First, remove the rubber cap from the terminator. Next, cut off the existing connector at the top of the terminator. Disconnect the ground lead from the base of the terminator, and finally, remove the entire terminator housing from the cable.
- Prepare the Cable
Prepare the cable for the new elbow connector. Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to precisely 10-1/2 inches from the bushing centerline. Verify the insulation shield measures less than 6-1/2 inches; if greater, consult an Elastimold representative. Carefully remove 1-3/8 inches of cable insulation from the end, ensuring a square cut and absolutely no nicks to the conductor.
- Install Compression Lug
Wire brush the bare aluminum conductor thoroughly. Immediately install the compression lug onto the conductor, rotating it to spread the inhibitor evenly. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart provided with the compression lug for specific crimping instructions. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Assemble Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not use substitutes. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe firmly with the probe wrench until the wrench bends.
- Connect Concentric Neutral
Connect the concentric neutral wires. Insert one end of a separate No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. Finally, add the supplied hose clamp as shown and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing Plug
Before connecting, ensure the transformer and elbow are known to be de-energized. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Using a full insulated hotstick, place the elbow connector receptacle over the bushing plug. Insert the elbow male contact into the bushing until the first slight resistance is felt (contacts are approximately 2 inches apart). Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Do not hold in the partially engaged position.
- Perform Voltage Test (168RLR Only)
For 168RLR models, perform a voltage test. Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until a "no voltage" indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it tightly on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.