- Nominal Fuse Voltage Rating: 8.3kV
- Fuse Test Port: Two Capacitive Test Ports
- Cable Insulation Diameter: 0.805 - 1.060 inch (20-27mm)
- Bi-Metal Conductor Size: 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact
- Connector Type: Bi-Metal Connector
Specifications
Amperage Rating | 200 A |
Application | Protect Light Duty Underground Distribution Systems |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Insulation | True |
Length | 16.87 in |
Length | 428.498 mm |
Material | Bi-Metal |
Material | EPDM-Rubber |
Series | 168FLR1 |
Size | Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm |
Special Features | Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching |
Standard | IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Fused Elbow Connector |
Voltage Rating | 8.3 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168RLR-K-5260
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168FLR1-C5240
8.3 kV, Fuse Elbow, No Fuse Included, Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
168FLR3-B5260
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact. Bi-Metal Connector.
168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
168FLR3-B5240
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
168FLR3-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
168FLR3-B5220-S
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Large Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket SealFrequently Asked Questions
What is the product's primary application?
The Elastimold 168FLR protects light duty underground distribution systems, including sub-loops and radial taps, by replacing existing 200 Amp loadbreak tap elbows.
How can a blown fuse be identified?
The 168FLR fused elbow has built-in voltage test points for quick and convenient blown fuse indication.
What items are included in each 168FLR kit?
Each kit contains an elbow connector housing, a crimp connector, a probe lug, four tubes of lubricant, installation instructions, and a crimp chart.
What types of conductors are compatible with the lugs?
Copper compression lugs are suitable for copper conductors only. Bi-metal compression lugs with universal aluminum barrels are suitable for copper or aluminum conductors.
What industry standards does the product meet?
The product meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47, Latest Revision.
Is the fused elbow hotstick operable?
Yes, the 168FLR Loadbreak Fused Elbow features hotstick operable 15kV Loadbreak Elbow switching.
Is the 168FLR fused elbow submersible?
Yes, the Elastimold 168FLR Loadbreak Fused Elbow is fully sealed and submersible.
What is the interrupting capability of the fused elbow?
The fused elbow has a symmetrical interrupting capability of 50,000 Amps and features full-range current-limiting fusing with 50kA interrupting capability.
What is the current rating range for this product?
The current rating for the 168FLR Loadbreak Fused Elbow is 3-80 Amps.
What voltage class is this fused elbow designed for?
This fused elbow is designed for the 15kV voltage class, with an 8.3kV nominal fuse voltage and 10kV maximum rated fuse voltage.
How to Install the 168FLR/274FLR Loadbreak Fused Elbow Connector
This guide provides step-by-step instructions for the safe and proper installation of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including detailed cable preparation and assembly procedures. Ensure all apparatus are de-energized before beginning installation.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Wire brush, Crimp tool, Special torque-limiting Allen wrench, Probe wrench, Hotstick, Measuring tape
Supplies needed:
Lubricant (supplied with kit), Copper wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector, Optional 200ECS Cold Shrink Cable Seal
- Prepare Cable Length and Neutral Wires
DANGER: Ensure all apparatus are de-energized before starting installation. Cut excess cable 20 inches minimum beyond the bushing. If using, slide the optional 200ECS Cold Shrink Cable Seal onto the cable. Remove the cable jacket for a length of 'A' + 7-3/8 inches from the bushing centerline. If a Cable Seal kit is used, follow its instructions; otherwise, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable at a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum for termination.
- Prepare Cable End and Install Compression Lug
Cut 1-1/8 inches from the cable end, ensuring a square cut and avoiding nicks to the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp (refer to the crimp chart). Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Lubricate and Insert Cable Half Housing
Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A', allowing the fuse to be tightened before bottoming on the rubber.
- Install and Tighten Fuse
Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand-thread it into the cable connector. CAUTION: Hand tighten only; the fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.
- Assemble and Align Probe Connector
Assemble the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the mating bushing. Lock the probe connector in position and tighten the setscrews using the special torque-limiting Allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.
- Assemble Elbow Halves and Probe
Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half, ensuring the cuff of the cable half overlaps the elbow half by 3/4 inch. Verify the probe connector faces the opening of the fused elbow half and the two test points are in line. Insert the probe into the probe connector, pushing on the cable if necessary to align it with the fuse. Hand-start the threads carefully to avoid cross-threading. Tighten the probe using the special torque-limiting Allen wrench supplied; insert the short end into the hole in the probe and tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it, but DO NOT OVERTIGHTEN.
- Connect Concentric Neutral Wires to Ground
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. Finish installing the 200ECS jacket seal, if used. Twist all neutral wires, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing Plug
DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection using a full insulated 'hotstick' type live-line tool, following company safe work practices for required tool length. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.