ABB - Installation Products 168FLR3-B5240 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

ABB Installation Products 168FLR3-B5240 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 075114286848


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3-B5240 molded current limiting fuse housing is designed for medium-voltage distribution systems requiring precise fault protection. This housing accommodates fuse voltages up to 8.3kV and supports cable insulation diameters from 0.635 inch (16mm) to 0.905 inch (23mm), making it compatible with a range of conductor sizes including 1/0 AWG stranded/compressed and 2/0 AWG solid/compact conductors. The unit features two capacitive test ports for safe diagnostic access without system de-energization, enabling efficient maintenance and testing procedures. Engineered for compatibility with ABB’s current limiting fuse solutions, this housing provides a robust enclosure that maintains electrical integrity under fault conditions. The bi-metal conductor interface ensures reliable thermal and mechanical performance, while the large housing design accommodates standard fuse assemblies for 8.3kV class systems. Typical applications include industrial substations, commercial power distribution, and utility networks where current limiting protection is critical to prevent equipment damage and minimize downtime.
  • Nominal fuse voltage rating: 8.3kV
  • Cable insulation diameter range: 0.635"–0.905" (16–23mm)
  • Conductor compatibility: 1/0 AWG stranded/compressed, 2/0 AWG solid/compact
  • Two capacitive test ports for safe diagnostic access
  • Part of ABB Installation Products catalog, UNSPSC 39121421

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
Molded
Material
EPDM-Rubber
Series
168FLR3
Size
Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
9.2200 L
Package Weight (Metric)
4.1820 kg
8.3 kV, 200 Amp, Fuse LoadBreak Elbow, Two Direct Test Points, Small Housing, Cable Insulation Diameter 0.890-1.220 inches, Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact, With Sealing Kit.

168AFLR1-D5240-S

8.3 kV, 200 Amp, Fuse LoadBreak Elbow, Two Direct Test Points, Small Housing, Cable Insulation Diameter 0.890-1.220 inches, Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact, With Sealing Kit.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR3-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Large Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal

168FLR3-B5220-S

8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Large Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal
15kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .575-.740 inches, Aluminum Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

168FLR1-A0250-SG3

15kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .575-.740 inches, Aluminum Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal

168FLR1-B5220-S

8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal
8.3kv Fuse Elbow 200 Amp, Loadbreak With Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact.

168FLR1-A5230-S

8.3kv Fuse Elbow 200 Amp, Loadbreak With Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact.
8.3kv Fused Elbow, 200 Amp, Loadbreak, No Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact.

168FLR1-A5230

8.3kv Fused Elbow, 200 Amp, Loadbreak, No Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact.
15kV, 200 Amp, Loadbreak Fused Elbow (Full Range Current Limiting), with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit. Large Housing for Fuse Size and Voltage Range 60-80 Amps 8.3 kV and 3-45 Amps 17.2 kV.

168FLR3-A5220

15kV, 200 Amp, Loadbreak Fused Elbow (Full Range Current Limiting), with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit. Large Housing for Fuse Size and Voltage Range 60-80 Amps 8.3 kV and 3-45 Amps 17.2 kV.

Frequently Asked Questions

What is the application of the 168FLR Fused Elbow?

The Elastimold 168FLR improves distribution system reliability by protecting light duty underground systems, sub-loops, and radial taps. It replaces existing 200 Amp loadbreak tap elbows.

Does the 168FLR Fused Elbow have a blown fuse indicator?

Yes, it has built-in voltage test points for quick and convenient blown fuse indication.

How do I determine the correct cable insulation diameter code?

Measure the cable's insulation diameter and select the letter code from the W table that best straddles that diameter.

How do I select the correct housing size for the Fused Elbow?

Select housing H Code 1 for 3-45A 8.3kV and 6-20A 15.5kV fuses, or H Code 3 for 65-80A 8.3kV and 3-45A 17.2kV fuses.

What items are included in the 168FLR Fused Elbow kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, lubricant tubes, installation instructions, and a crimp chart.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are suitable for all copper conductors. Bi-metal compression lugs are suitable for copper or aluminum conductors.

Is the 168FLR Fused Elbow submersible?

Yes, the Elastimold Fused Elbow is fully sealed and submersible.

How is fuse replacement handled in the 168FLR Fused Elbow?

The Fused Elbow features a split center section designed for easy fuse replacement.

What is the interrupting capability of the 168FLR Fused Elbow?

The Fused Elbow has a 50,000 Amp symmetrical interrupting capability. It features full-range current-limiting fusing.

What is the current rating range of the 168FLR Fused Elbow?

The Fused Elbow has a current rating range of 3-80 Amps.

How to Install the 168FLR/274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and neutral connections.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Allen Wrench (torque limiting, supplied), Wire brush, Crimp tool

Supplies needed:

Fuse (supplied), Compression Lug (supplied), Probe (supplied), Probe Connector (supplied), Hose Clamp (supplied), Lubricant (supplied), Copper wire (No. 14 AWG / 2.5mm or equivalent), Optional: 200ECS Cold Shrink Cable Seal

  1. Observe Safety Precautions and Perform Initial Checks

    DANGER: All apparatus must be de-energized during installation or removal of part(s) except for test point caps and indicators that can be installed and operated energized. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. IMPORTANT: Check package contents for completeness and damage. Check all components for proper fit with cable and/or mating products. Check threads by threading probe into compression lug; replace damaged components if resistance is encountered. Read entire instructions before starting. Have all required tools at hand and maintain cleanliness.

  2. Prepare Cable Length

    Cut excess cable to 20 inches minimum beyond the bushing centerline. Remove the cable jacket for the distance of "A" (fuse body length) + 7-3/8 inches from the bushing centerline. If using a Cable Seal kit, follow its instructions. Otherwise, unwrap and fold concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of "A" from the bushing centerline, leaving 7-3/8 inches minimum of cable to terminate. ("A" = 11-1/2" for FLR-1, 15-3/4" for FLR-3).

  3. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches from the cable end, squarely, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Crimp the unthreaded end of the compression lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Refer to the crimp chart with the lug. Carefully wipe excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug. Bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Lubricate and Insert Cable into Cable Half Housing

    Apply lubricant (supplied) to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface "A". This allows the fuse to be tightened before bottoming on the rubber.

  5. Install and Hand Tighten the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. Hand tighten the fuse. CAUTION: Fuse stud will fracture if over torqued. Pull the cable half housing up against the bottom of the tightened fuse.

  6. Assemble Probe Connector and Align Test Point

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Halves and Insert Probe

    Apply lubricant to the elbow half of the fused elbow. Assemble the elbow half to the cable half of the fused elbow, ensuring the cuff of the cable half overlaps the elbow half by 3/4 inch. Make sure the probe connector faces the opening of the fused elbow half, and the two test points are in line with each other. Insert the probe into the probe connector. Start the probe threads by hand, taking care not to cross-thread. Tighten the probe using the special torque limiting allen wrench supplied; tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  8. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eye. If a 200ECS jacket seal was used, finish installing it. Twist all neutral wires, exercising care not to damage grounding eyes, and connect to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  9. Connect Elbow to Bushing Plug (De-energized)

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate per following instructions (referring to operating instructions for hotstick use). DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.