Authorized ABB Distributor (Installation Products)
ABB - Installation Products 168FLR3-B5260 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact. Bi-Metal Connector.

ABB Installation Products 168FLR3-B5260 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 075114197793


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3-B5260 molded current limiting fuse housing is a high-voltage protection solution engineered for 8.3kV medium-voltage distribution systems. This large housing unit accommodates cable insulation diameters from 0.635 inch to 0.905 inch (16-23mm) and supports bi-metal conductors in sizes 3/0 AWG stranded/compressed or 4/0 AWG solid/compact. The housing features two capacitive test ports for safe voltage verification without system de-energization, enabling efficient maintenance and diagnostics. Designed for medium-voltage applications, the 168FLR3-B5260 provides reliable current limiting to protect downstream equipment from fault conditions. The bi-metal conductor ensures compatibility with both stranded and solid conductor types, offering flexibility in installation while maintaining high conductivity and thermal stability. The molded construction delivers robust mechanical strength and environmental resistance, suitable for indoor and outdoor applications. Its design aligns with ABB’s Installation Products series, ensuring compatibility with standard fuse components. The SKU 168FLR3-B5260 is part of a trusted line of protection devices, providing a cost-effective solution for current limitation in 8.3kV class systems.
  • Nominal fuse voltage rating: 8.3kV
  • Cable insulation diameter range: 0.635"–0.905" (16–23mm)
  • Bi-metal conductor compatibility: 3/0 AWG stranded/compressed or 4/0 AWG solid/compact
  • Two capacitive test ports for safe voltage verification without de-energization
  • Molded construction for mechanical strength and environmental resistance

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection Type
Compressed/Solid
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
Bi-Metal
Material
EPDM-Rubber
Series
168FLR3
Size
0.635-0.905 inch (16-23mm)
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact. Bi-Metal Connector.

168FLR1-C5260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact. Bi-Metal Connector.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR3-B5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR3-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Large Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal

168FLR3-B5220-S

8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Large Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal
15kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .575-.740 inches, Aluminum Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

168FLR1-A0250-SG3

15kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .575-.740 inches, Aluminum Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal

168FLR1-B5220-S

8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. With Jacket Seal
8.3kv Fuse Elbow 200 Amp, Loadbreak With Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact.

168FLR1-A5230-S

8.3kv Fuse Elbow 200 Amp, Loadbreak With Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact.

Frequently Asked Questions

What is the primary application of this product?

The Elastimold 168FLR combines full-range current-limiting fusing with 15kV hot stick operable, loadbreak elbow switching to protect light duty underground distribution systems.

How is a blown fuse indicated?

The product includes built-in voltage test points for quick and convenient blown fuse indication.

What is the frequency rating of the device?

The device is rated for a frequency of 50/60 Hz.

What types of conductors are compatible with the lugs?

Copper compression lugs are suitable for all copper conductors. Bi-metal compression lugs are suitable for copper or aluminum conductors.

What is the impulse withstand rating?

The impulse withstand rating is 95kV BIL, based on a 1.2 x 50 microsecond wave.

What industry standards does the product meet?

The product meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47, Latest Revision.

Can this product be used in submersible environments?

Yes, the Elastimold Fused Elbow is fully sealed and submersible.

What is the symmetrical interrupting capability?

The product has a symmetrical interrupting capability of 50,000 Amps.

What is the current rating range for the fuses?

The current rating for the fuses is between 3 and 80 Amps.

What voltage class is this fused elbow designed for?

This fused elbow is designed for a 15kV voltage class, with an 8.3kV nominal fuse voltage and a 10kV maximum rated fuse voltage.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and assembly of the 168FLR Loadbreak Fused Elbow Connector. It covers cable preparation, component assembly, and neutral wire connection for terminating UD cable.

Estimated time: 1h 30m

Tools needed:

Wire brush, Crimp tool, Special torque limiting Allen wrench, Hotstick

Supplies needed:

Compression Lug, Lubricant, Fuse, Probe Connector, Probe, Hose Clamp, No. 14 AWG (2.5mm) copper wire, Grounding connector

  1. Prepare Cable Jacket and Neutral Wires

    De-energize all apparatus before starting. Using the bushing centerline as a reference, cut excess cable. Remove the cable jacket for the specified length (distance 'A' + 7-3/8" from bushing centerline). Unwrap and fold the concentric neutral wires back over the jacket, then bind them. Finally, squarely cut off the cable a distance of 'A' from the bushing centerline, leaving 7-3/8" minimum for termination. (Note: 'A' is 11-1/2" for FLR-1 or 15-3/4" for FLR-3).

  2. Install Compression Lug and Clean Insulation

    Cut 1-1/8" from the cable end, ensuring a square cut without nicking the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Crimp the unthreaded end of the compression lug to the conductor, following the crimp chart and rotating 180 degrees for each successive crimp. Wipe off excess inhibitor. Remove the insulation shield 5-1/2" from the end of the lug and bevel the insulation end 1/8" maximum. Thoroughly clean the insulation to remove all conductive residue.

  3. Lubricate and Insert Cable Half

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This ensures the fuse can be tightened without bottoming on the rubber.

  4. Install the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand-tighten it into the cable connector. CAUTION: Do not over-torque the fuse stud to prevent fracture. Pull the housing up against the bottom of the tightened fuse.

  5. Assemble Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the mating bushing. Lock the probe connector in position and tighten the setscrews using the special torque-limiting Allen wrench provided in the fuse kit. Rotate the cable half of the Fused Elbow so the test point is perpendicular to the flats on the probe connector.

  6. Assemble Elbow Halves and Insert Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half, ensuring the cable half cuff overlaps the elbow half by 3/4". Verify the probe connector faces the opening of the fused elbow half and the two test points are in line. Insert the probe into the probe connector, starting threads by hand to avoid cross-threading. Tighten the probe using the special torque-limiting Allen wrench supplied, inserting the short end into the probe hole and tightening until the wrench bends and remains bent. Finally, position and tighten the hose clamp, but do not overtighten.

  7. Connect Concentric Neutral Wires to Ground

    Using a separate No. 14 AWG (2.5mm) copper wire, insert one end through each grounding eye on the elbow and cable housings and twist tightly. Twist all neutral wires together, taking care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation.

  8. Lubricate Mating Bushing

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Do not operate by hand; use a hotstick as per operating instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.