ABB Installation Products 167LRT-G5220-S 15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to…
UPC: 075114248822
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15 kV voltage rating for medium-voltage applications.
- 200 Amp current rating for substantial power handling.
- Bi-metal compression lug for durable conductor connections.
- Accommodates cable insulation diameters from 0.760" to 0.950".
- Includes 200ECS jacket seal for environmental protection.
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amps |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Special Features | Includes 02800X Bi-Metal Contact |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Bolted Elbow with Tap |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B-5220
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug
K151SP-C2200
15kv Dead Break 200 Amp Straight Plug Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
K151SR-C2200
15kv Straight Receptacle N-sealing Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #4 or Solid #3 or mmSquared 21.14
274ELR-88110-5240
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact., No Sealing Kit, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
376LR-K5270-SG3
35KV, LoadBreak, 200 Amp, With Cold Shrink-Fit Jacket Seal Kit with Copper Braid and Constant Force Spring
167ELR-88110-5260
200 Amp, LoadBreak, 15KV, Repair Elbow Connector, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
376LR-L5260
35 kv, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
168RLR-G-5240-S
15 kv, 200 Amp, Loadbreak Elbow, Replacement, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What items are included in the 167LRT kit?
The kit includes the elbow connector housing, a compression lug, a stud extender, lubricant, an installation tool, a wrench, and installation and crimp instructions.
What standards does the product conform to?
The product's ratings conform to ANSI/IEEE Standard 386. It also mates with bushing wells conforming to ANSI Std. 386, Fig. 3.
What are the voltage withstand ratings?
It has a 95kV BIL impulse withstand, 34kV AC one-minute withstand, and 53kV DC 15-minute withstand.
What is the continuous current rating?
The continuous and loadbreak current rating for the product is 200 Amps.
What is the maximum operating voltage?
The maximum phase-to-ground operating voltage is 8.3 kV, and the maximum phase-to-phase voltage is 14.4 kV.
What are the key features of the 167LRT?
It is a 15kV, 200A deadbreak elbow connector with a loadbreak tap point. It features a fully-shielded, submersible molded rubber housing and peroxide-cured insulation.
What is the product's primary function?
The 167LRT Bolted Elbow with Tap is a loadbreak elbow connector with a loadbreak tap, rated as a 200 AMP, 15kV deadbreak connector.
What is the maximum operating voltage?
The maximum phase-to-ground operating voltage is 8.3 kV, and the maximum phase-to-phase voltage is 14.4 kV.
What standards does the product conform to?
The product's ratings conform to ANSI/IEEE Standard 386. It also mates with bushing wells conforming to ANSI Std. 386, Fig. 3.
What items are included in the 167LRT kit?
The kit includes the elbow connector housing, a compression lug, a stud extender, lubricant, an installation tool, a wrench, and installation and crimp instructions.
How to Install the Elastimold 167LRT Loadbreak Bushing Tap
This guide provides step-by-step instructions for the safe installation and initial setup of the Elastimold 167LRT Loadbreak Bushing Tap, including cable preparation, assembly, and grounding. Ensure all apparatus is de-energized before starting.
Estimated time: 2h
Tools needed:
Wrenches, Installation tool, Wire brush, Crimp tool
Supplies needed:
Bushing Tap Housing, Compression Lug, Socket Contact, Lubricant (Do Not Substitute), Well Contact, UD cable, No. 14 AWG (2.5mm) copper wire or equivalent, Appropriate ground connector, Insulated cap or mating elbow connector
- De-energize and Prepare the Cable
DANGER: Ensure all apparatus is de-energized before beginning installation. Train the UD cable to ease operation, then cut excess cable squarely at the bushing's center line. Unwrap and bind concentric neutral wires 8-1/2 inches back from the cable end. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the lug and cable. Remove the semi-con shield and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Bushing Well Contact and Initial Bushing Tap Components
Thread the well contact onto the bushing well stud by hand, taking care not to cross-thread. Tighten with a wrench until the wrench bends, signifying proper torque. Remove the protective cap from the bushing tap and retrieve the socket contact stored inside the bushing tap housing. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant; DO NOT SUBSTITUTE. Keep insulation clean and do not introduce excess grease or grease into the gap between the lug and insulation.
- Mount the Bushing Tap and Connect Neutral
Slide the bushing tap onto the cable with a back-and-forth twisting motion, then wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole. Inspect the apparatus bushing well to ensure it is dry and free from contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied or ELASTIMOLD approved lubricant. Place the lubricated bushing tap portion into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until fully seated. Insert a wrench through the wrench hole of the tool and turn clockwise until the wrench bends, indicating proper assembly torque. Remove the wrench and installation tool. Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap and twist it tight without damaging the eye. Twist the neutral wires and connect them to ground using an appropriate connector.
- Final Lubrication and Mating Product Connection
Thoroughly wipe the bushing tap interface clean of any contaminants and apply a light, uniform coat of supplied lubricant, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated in the 'locked on' position. Install the mating products (e.g., loadbreak elbow, insulated cap, or grounding elbow connector) to the bushing tap following their specific instructions. If a mating product is not immediately installed, replace the shipping cap. Do not energize or submerge the apparatus with only the shipping cap, as it is not insulated or watertight.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.