ABB - Installation Products K151SR-C2200 - 15kv Straight Receptacle N-sealing Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #4 or Solid #3 or mmSquared 21.14

ABB Installation Products K151SR-C2200 15kv Straight Receptacle N-sealing Cable Insulation Diameter 0.805 inch to 1.060 inch.…

UPC: 075114256537


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-C2200 is a 15kV straight receptacle with N-sealing designed for medium-voltage cable terminations. This product accommodates cable insulation diameters from 0.805 inch to 1.060 inch, making it suitable for a range of industrial applications including power distribution, substations, and renewable energy systems. The copper compression lug ensures reliable electrical contact and mechanical strength, supporting compressed stranded conductors in AWG #4 or solid conductors in AWG #3, equivalent to 21.14 mm² cross-sectional area. The N-sealing design provides environmental protection against moisture and contaminants, critical for outdoor and harsh environment installations. This receptacle is part of ABB's Installation Products catalog, ensuring compatibility with ABB's medium-voltage systems and industry-standard accessories. The compact design allows for efficient cable management and space-saving installations in control panels or switchgear. Ideal for utility companies, industrial plants, and infrastructure projects requiring dependable medium-voltage connections with minimal maintenance.
  • 15kV rated straight receptacle with N-sealing for medium-voltage applications
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Copper compression lug for secure electrical and mechanical connection
  • Supports compressed stranded AWG #4 or solid AWG #3 conductors (21.14 mm²)
  • Part of ABB Installation Products catalog for medium-voltage systems

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
#4 STR/COMPR AWG , #3 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

K151-SR-A0200

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact., No Sealing Kit, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274ELR-88110-5240

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact., No Sealing Kit, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
35KV, LoadBreak, 200 Amp, With Cold Shrink-Fit Jacket Seal Kit with Copper Braid and Constant Force Spring

376LR-K5270-SG3

35KV, LoadBreak, 200 Amp, With Cold Shrink-Fit Jacket Seal Kit with Copper Braid and Constant Force Spring
200 Amp, LoadBreak, 15KV, Repair Elbow Connector, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

167ELR-88110-5260

200 Amp, LoadBreak, 15KV, Repair Elbow Connector, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
35 kv, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

376LR-L5260

35 kv, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
15 kv, 200 Amp, Loadbreak Elbow, Replacement, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.

168RLR-G-5240-S

15 kv, 200 Amp, Loadbreak Elbow, Replacement, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.
35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No Seal

376LR-K2260

35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No Seal
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

167ELR-6689-5220-SG3

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

Frequently Asked Questions

What is the voltage rating of this receptacle?

The K151SR-C2200 is rated for 15kV medium-voltage applications.

What cable insulation diameter does this receptacle support?

The K151SR-C2200 supports cable insulation diameters ranging from 0.805 inch to 1.060 inch.

Does this product come with a compression lug?

Yes, the K151SR-C2200 includes a copper compression lug for secure electrical and mechanical connections.

What conductor sizes are compatible with this receptacle?

The receptacle accepts compressed stranded conductors in AWG #4 or solid conductors in AWG #3, equivalent to 21.14 mm².

Is this receptacle rated for outdoor use?

The N-sealing design provides environmental protection, making it suitable for outdoor and harsh environment installations.

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for the safe and proper installation of the 151SR/K151SR Straight Receptacle, including cable preparation, crimping, lubrication, and grounding procedures for high voltage electrical systems. Ensure all apparatus are de-energized before starting.

Estimated time: 1h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Rag, Approved solvent, Elastimold bail

Supplies needed:

Solid dielectric type cable, #14 AWG copper wire or equivalent, Sealing material, Silicone grease, Elastimold insulating plug (if needed), HV insulated cap(s) or connector(s)

  1. Prepare the Cable Jacket

    De-energize all apparatus. For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end.

  2. Remove Insulation and Prepare Conductor

    Remove 7/8 to 1 inch (or 1 3/4 to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel, which contains inhibitor.

  3. Crimp the Socket Terminal

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  4. Prepare and Clean Cable Insulation

    Remove the semi-conductive shield 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut. DO NOT CUT OR NICK THE INSULATION. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket.

  5. Lubricate the Receptacle and Cable

    Remove the protective cap from the straight receptacle. Keep the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the instructions and to the inside of the housing. DO NOT SUBSTITUTE; other lubricants may be harmful to the product or its mating product.

  6. Insert Cable into Receptacle Housing

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover. Note that the shipping cover offers protection from dirt only and is not an insulating device. Obtain an Elastimold insulating plug (K150DP) if an insulating device is required.

  7. Connect to a Mating Plug (Optional)

    If connecting to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail.

  8. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.