ABB Installation Products 168RLR-G-5240-S 15 kv, 200 Amp, Loadbreak Elbow, Replacement, Cable Insulation Diameter 0.760 inch to…
UPC: 075114277501
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15 kV, 200 Amp loadbreak elbow connector
- Cold-shrinkable jacket seal for simplified installation and environmental protection
- Accommodates cable insulation diameters from 0.760 to 0.950 inches (Insulation Letter Code 'B')
- Designed for medium-voltage power distribution applications
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection Type | Compression Lug |
Connection Type | Loadbreak Elbow |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal, Poly (Cold-Shrinkable Jacket Seal) |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Compression Lug, Cold-Shrinkable Jacket |
Series | 168RLR |
Series | 168RLR-G-5240-S |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Size | Cable Insulation Diameter 0.760-0.950 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B-2240
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
376LR-K2260
35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No Seal
167ELR-6689-5220-SG3
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
167ELR-6689-5220
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. No Seal
376LR-K5240-S
35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal
273ELR-7495-5250
25kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow. Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal
167ELR-7495-5250
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal
167ELR-6689-5210
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No SealFrequently Asked Questions
What type of product is the 168RLR?
The 168RLR is an Elastimold 200 A loadbreak replacement elbow connector with a test point.
What is the function of the capacitive test point?
The capacitive test point allows for testing the circuit to determine the presence of voltage.
Where are Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.
What standards do these elbow connectors meet?
These elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What cable insulation diameter does the 'G' symbol represent?
For the 168RLR, the 'G' symbol indicates a cable insulation diameter range of 0.760 to 0.950 inches.
Is a jacket seal included with the 168RLR-S product?
Yes, the "S" suffix indicates that a 200ECS jacket seal is included, which is highly recommended.
Does the 168RLR elbow include a test point?
Yes, the 168RLR is a replacement elbow that includes a built-in capacitive test point.
How much extended length does the replacement elbow provide?
The replacement elbow provides a net gain of 8 7/8 inches in length.
What is the current rating of these elbow connectors?
These loadbreak elbow connectors are rated for 200 A.
What is the voltage class of the 168RLR elbow?
The 168RLR replacement elbow is rated for a 15 kV voltage class.
How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors
This guide provides step-by-step instructions for installing the 167RLR (without Test Point) and 168RLR (with Test Point) Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cable. All apparatus must be de-energized during installation or removal of parts.
Estimated time: 1h 30m
Tools needed:
Hotstick, Probe Wrench, Wire brush, Wire strippers, Crimping tool, Suitable sensing device for capacitive test points
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate connector for ground, HV insulated cap(s) or connector(s)
- De-energize Apparatus and Perform Initial Checks
Ensure all apparatus is de-energized before beginning installation or removal of any parts. Verify package contents are complete and undamaged, and check all components for proper fit with the cable and mating products. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered. Read all instructions thoroughly and gather all required tools.
- Remove Livefront Terminator
Remove the rubber cap from the terminator. Cut off the existing connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Carefully remove the terminator housing from the cable.
- Prepare the Cable
Train the cable to be straight and in-line with the bushing centerline. Cut the cable precisely to 10-1/2 inches from the bushing centerline. Remove 1-3/8 inches of cable insulation from the end of the cable, ensuring a square cut and taking care not to nick the conductor. If the insulation shield measures less than 6-1/2 inches, proceed; otherwise, consult an ELASTIMOLD representative.
- Install Compression Lug
Wire brush the bare aluminum conductor immediately. Install the compression lug, rotating it to spread the inhibitor. Align the lug's contact threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Assemble Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Connect Concentric Neutral
Insert one end of a No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tight, being careful not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. Add the supplied hose clamp and tighten it snugly, but do not overtighten.
- Prepare for Final Connection to Bushing
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. This lubrication step should only be performed if the transformer and elbow are confirmed to be de-energized. Do not operate the connection by hand; use appropriate live-line tools as per operating instructions.
- Perform Voltage Test (168RLR Only)
For 168RLR models, remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, designed for capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.