Authorized ABB Distributor (Installation Products)
ABB - Installation Products 162LR-C5270 - 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug

ABB Installation Products 162LR-C5270 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable…

UPC: 075114188067


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-C5270 is a 15kV, 200 Amp loadbreak elbow connector designed for reliable power distribution applications. This connector is engineered to accommodate cable insulation diameters ranging from .805 inches to 1.060 inches, making it suitable for a variety of medium-voltage cable sizes. It is specifically designed for use with 4/0 stranded wire, ensuring robust electrical contact and conductivity. The integrated test point provides a convenient and safe method for voltage testing and system diagnostics without de-energizing the circuit. Constructed with a bi-metal compression lug, this elbow connector offers excellent conductivity and corrosion resistance, crucial for long-term performance in electrical infrastructure. This component is part of ABB's Installation Products catalog, known for its dependable electrical connection solutions. The 162LR-C5270 is a key component for utility, industrial, and commercial power systems requiring secure and tested loadbreak connections. Its design prioritizes safety and operational efficiency for electrical maintenance and operation professionals. UNSPSC Code: 39121421.
  • 15kV voltage rating for medium-voltage applications
  • 200 Amp continuous current rating
  • Integrated test point for safe voltage verification
  • Accommodates cable insulation diameters from .805" to 1.060"
  • Designed for 4/0 AWG stranded wire with a bi-metal compression lug

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Push-In
Connection Type
Loadbreak Elbow Connector with Test Point
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
162LR
Size
0.805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
10.5 IN x 19.12 IN x 12.5 IN
Package Dimensions (L x W x H)
26.67 cm x 48.5648 cm x 31.75 cm
Package Weight (Imperial)
2.1300 L
Package Weight (Metric)
0.9660 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5240

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

162LR-C5240C

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

162LR-C5240-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-C5240-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5230

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

162LR-C5230A

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long

USK 350 SL

Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long

Frequently Asked Questions

What material is the pulling eye made from?

The pulling eye is made from robust stainless steel, promoting durable hotstick control.

What is the purpose of the rigid probe support?

The rigid probe support ensures proper switching and easy probe installation.

How does the elbow reduce life cycle costs?

It is optimized for switching operations, offers lifetime ease of operation and non-stick performance with Elastimold bushings, and has an improved seal system.

How does the enhanced elbow offer increased flexibility?

It offers additional sizes, improved wider cable ranges, an easy order system, and an optional integral jacket seal.

What standards and certifications does the product meet?

The product is IEEE 386 compliant and has ANSI certification, in addition to Rural Utilities Service (RUS) acceptance.

Does the loadbreak elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What safety features are included in the enhanced elbow?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, and a robust stainless-steel pulling eye. It also has dual grounding eye positions.

What are the voltage ratings for this loadbreak elbow?

The enhanced Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow designed for 15 kV and 25 kV series, incorporating innovative design and manufacturing experience.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow designed for 15 kV and 25 kV series, incorporating innovative design and manufacturing experience.

How to Install the 162LR Loadbreak Elbow Connector

This guide provides detailed instructions for the safe installation and assembly of the 162LR Loadbreak Elbow Connector, including cable preparation, lug installation, and final connection to a 15kV class bushing.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool, Knife, Probe wrench, Hotstick tool, Cleaning cloth

Supplies needed:

162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral wires), Cable sealing kit (if applicable), Conductive copper tape (if using specific sealing kits), Vinyl tape (if using specific cable types)

  1. Perform Initial Safety Checks and Component Verification

    DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed by competent personnel trained in high voltage electrical equipment safety. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading into the compression lug; replace damaged components if resistance is encountered. Have all required tools ready and maintain cleanliness.

  2. Prepare Cable for Termination

    Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the product manual (Step 1) to prepare the cable end, including unwrapping neutral/ground wires, cutting the cable squarely, and applying any necessary sealing kits or tape. Ensure an extra length of neutral wires or grounding braid is available for connection to tank ground.

  3. Prepare Cable End and Install Compression Lug

    Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush the bare aluminum conductors immediately. Install the compression lug, rotating it to spread inhibitor, and align its threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt or inhibitor traces.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  5. Establish Grounding Connections

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete the grounding process.

  6. Connect Elbow to Bushing Plug

    DANGER: Confirm that both the transformer and the elbow are de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.