ABB - Installation Products 162LR-C5240-S - 200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

ABB Installation Products 162LR-C5240-S 200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060…

UPC: 075114187992


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-C5240-S is a 200 Amp, 15kV loadbreak elbow connector engineered for medium-voltage cable systems in utility, industrial, and commercial power distribution networks. This bi-metal compression lug connector accommodates cable insulation diameters from 0.805 inch to 1.060 inch, making it compatible with 1/0 AWG compressed stranded and solid conductors, as well as 53.49 mm² conductors. The included 200ECS jacket seal ensures environmental protection and dielectric integrity in underground or aerial distribution systems. It is ideal for applications involving underground residential distribution (URD), pad-mounted transformers, and switchgear where loadbreak operation is necessary for maintenance or system reconfiguration. The bi-metal construction provides corrosion resistance and long-term conductivity, while the compression lug design ensures a secure, low-resistance connection. The catalog number selection follows a structured process: Step 1 determines the insulation diameter and selects the corresponding letter code (C for 0.805-1.060 inch), Step 2 uses the standard material code (5 for bi-metal), and Step 3 selects the compression lug code (240 for 1/0 to 2/0 AWG or 53.49 mm²). This connector is part of ABB’s Installation Products line, a trusted manufacturer in electrical infrastructure solutions.
  • 200 Amp, 15kV phase-to-phase voltage rating
  • Accommodates cable insulation diameters from 0.805 inch to 1.060 inch
  • Compatible with 1/0 AWG compressed stranded/solid and 53.49 mm² conductors
  • Bi-metal compression lug for corrosion resistance and long-term conductivity
  • Includes 200ECS jacket seal for environmental protection and dielectric integrity

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
LoadBreak Elbow Connector
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
162LR
Size
Cable Insulation Diameter 0.805 inch to 1.060 inch
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5240

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-C5240-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5230

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

162LR-C5230A

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long

USK 350 SL

Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long
Flood Seal, Aluminum Mechanical Splice kit, #2-500 kcmil, Aluminum and Copper, Aluminum Connector 4.5 inch long with Streetlight option, 1 screw per side

USK 500-4.5 SL

Flood Seal, Aluminum Mechanical Splice kit, #2-500 kcmil, Aluminum and Copper, Aluminum Connector 4.5 inch long with Streetlight option, 1 screw per side
Flood Seal, Aluminum Mechanical Splice kit, 1.81 inch long connector, #10 wire, 4 sides, 2 screws per side, includes Connector, Insulating Cap with Liner and Rocket, Silicone Grease

USK 410

Flood Seal, Aluminum Mechanical Splice kit, 1.81 inch long connector, #10 wire, 4 sides, 2 screws per side, includes Connector, Insulating Cap with Liner and Rocket, Silicone Grease
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

261LRJS-D5270

25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

Frequently Asked Questions

What material is the pulling eye made from?

The loadbreak elbow features a robust stainless-steel pulling eye, which promotes durable hotstick control.

Does the loadbreak elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What standards and certifications does the product meet?

The enhanced loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What are the voltage and current ratings for this elbow?

The enhanced loadbreak elbow is rated for 200 amps and is suitable for 15 kV and 25 kV applications.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV systems, designed for easier switching operations.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV systems, designed for easier switching operations.

What are the voltage and current ratings for this elbow?

The enhanced loadbreak elbow is rated for 200 amps and is suitable for 15 kV and 25 kV applications.

What standards and certifications does the product meet?

The enhanced loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

Does the loadbreak elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What material is the pulling eye made from?

The loadbreak elbow features a robust stainless-steel pulling eye, which promotes durable hotstick control.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR and 162LR Loadbreak Elbow Connectors on various UD cables, including cable preparation, lug installation, elbow assembly, and grounding.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool, Hotstick, Probe wrench

Supplies needed:

Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral to ground), Cold shrink tube (if using sealing kit), Conductive copper tape (if using sealing kit), Vinyl tape (if binding drain wires)

  1. Perform Pre-Installation Checks and Cable Training

    Before starting, ensure all apparatus is de-energized. Inspect all package contents and components for completeness, damage, and proper fit with the cable and mating products. Read the entire instructions. Train the cable to ensure sufficient slack for operation. Depending on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the documentation to prepare the neutral/drain wires and remove the outer jacket. Cut the excess cable squarely at the centerline of the bushing. DANGER: All apparatus must be de-energized during installation or removal of parts. Failure to follow these instructions will result in serious or fatal injury. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Cable End and Install Compression Lug

    Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush any bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the cable cut-back diagram, and bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  4. Connect Grounding Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. If the elbow was preordered with a ground wire, proceed to the next step. For concentric neutral cables, twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the grounding installation.

  5. Connect Elbow to Bushing Plug

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND. DANGER: Confirm that the transformer and elbow are de-energized. DO NOT OPERATE BY HAND. Use a full insulated 'hotstick' type tool.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.