ABB - Installation Products 162LR-C5240 - 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug

ABB Installation Products 162LR-C5240 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable…

UPC: 075114187985


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-C5240 is a 15 kV, 200 Amp loadbreak elbow connector designed for reliable separable connections in medium-voltage power distribution systems. This connector features a bi-metal compression lug for stranded copper conductors, ensuring durable and low-resistance terminations. It accommodates cable insulation diameters from 0.805 inches to 1.060 inches, making it ideal for 1/0 AWG stranded wire applications. The integrated test point enables safe voltage verification without disconnecting the system, enhancing operational safety and diagnostic efficiency. Engineered for underground residential distribution (URD) and other medium-voltage networks, the 162LR-C5240 simplifies maintenance and fault isolation by allowing quick disconnection under load. Its robust construction prioritizes electrical integrity, with a bi-metal lug that resists corrosion and ensures long-term performance. The connector is part of ABB’s 15 kV loadbreak elbow series, designed for compatibility with standard bushings in utility and industrial power systems. Key specifications include a 15 kV voltage rating, 200 A current rating, and bi-metal compression lug for 1/0 AWG stranded copper conductors. The connector’s design facilitates easy installation and mating with compatible bushings, reducing downtime during maintenance or upgrades. With a focus on reliability and safety, the ABB 162LR-C5240 is a critical component for medium-voltage systems requiring secure, separable connections.
  • 15 kV voltage rating for medium-voltage applications
  • 200 Amp current rating with bi-metal compression lug for 1/0 AWG stranded copper conductors
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Integrated test point for safe voltage verification without disconnection
  • Designed for underground residential distribution (URD) and medium-voltage systems
  • Integrated Test Point for safe voltage verification

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.1300 L
Package Weight (Metric)
0.9660 kg
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

162LR-B-2240

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

162LR-C5240C

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

162LR-C5240-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-C5240-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5230

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

162LR-C5230A

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long

USK 350 SL

Flood Seal Aluminum Mechanical Splice Kit, #6-350 kcmil, Aluminum and Copper, StreetLight Option, Screws per side 1, Connector Length 2.54 inch, Rocket/Cap 10.1 inch long
Flood Seal, Aluminum Mechanical Splice kit, #2-500 kcmil, Aluminum and Copper, Aluminum Connector 4.5 inch long with Streetlight option, 1 screw per side

USK 500-4.5 SL

Flood Seal, Aluminum Mechanical Splice kit, #2-500 kcmil, Aluminum and Copper, Aluminum Connector 4.5 inch long with Streetlight option, 1 screw per side

Frequently Asked Questions

What certifications does the loadbreak elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the product's current and voltage rating?

The product is a 200 amp loadbreak elbow designed for 15 kV and 25 kV applications.

What is the product's current and voltage rating?

The product is a 200 amp loadbreak elbow designed for 15 kV and 25 kV applications.

What certifications does the loadbreak elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What certifications does the loadbreak elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the product's current and voltage rating?

The product is a 200 amp loadbreak elbow designed for 15 kV and 25 kV applications.

What is the product's current and voltage rating?

The product is a 200 amp loadbreak elbow designed for 15 kV and 25 kV applications.

What certifications does the loadbreak elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the product's current and voltage rating?

The product is a 200 amp loadbreak elbow designed for 15 kV and 25 kV applications.

What certifications does the loadbreak elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, elbow assembly, and grounding.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Hotstick (Insulated Live-Line Tool), Wire Brush, Crimp Tool, Cable Stripping Tools, Voltage Sensing Device (for 162LR), Vinyl Tape

Supplies needed:

161LR or 162LR Loadbreak Elbow Connector, Lubricant (supplied with connector), Copper Ground Wire (No. 14 AWG / 2.5mm, if not pre-installed), Neutral Wire Connector, Cold Shrink Sealing Kit (if applicable), Conductive Copper Tape (if using 200ECS-G2/G3 kit), Silicone Lubricant (for 162LR test point cap)

  1. Perform Initial Checks and Safety Precautions

    Before starting, ensure all apparatus are de-energized. Verify the package contents are complete and undamaged. Check all components for proper fit with the cable and/or mating products. Thread the probe into the compression lug to check for resistance. Read the entire installation instructions and have all required tools at hand, maintaining cleanliness throughout the procedure. This product must be installed by competent personnel trained in high voltage safety practices.

  2. Prepare Cable End for Termination

    Refer to the documentation for your specific cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) to properly train the cable, manage neutral/drain wires, and cut the outer jacket and shield to the specified lengths. For all cable types, ensure adequate slack for operation. If using a cold shrink sealing kit (e.g., 200ECS, 200ECS-G1, 200ECS-G2/G3), slide the cold shrink tube onto the cable loose end first at this stage.

  3. Install Compression Lug and Prepare Insulation

    Remove the shield and insulation 2-1/8” (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with it, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the lug and cable. Remove the insulation shield 6-7/8” (175mm) and bevel the insulation end 1/8” (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back and forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Ground the Elbow Connector

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye. If the elbow is preordered with a ground wire, proceed to connect all neutral wires to ground using an appropriate connector, ensuring adequate slack in wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the installation.

  6. Connect Elbow to Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

  7. Perform Voltage Test (162LR Only)

    For 162LR connectors equipped with an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor; do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points and follow its manufacturer’s directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.