ABB Installation Products 161LR-B5240 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch.…
UPC: 075114236164
Contact for Pricing
Minimum Qty: 12
Multiplier: 12
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV rated voltage for medium-voltage applications
- 200 Amp maximum current capacity
- Accommodates cable insulation diameters from 0.635" to 0.905"
- Supports compressed stranded conductors 1/0-2/0 AWG (53.49 mm²) and solid 2/0 AWG
- Bi-metal copper compression lug for secure, corrosion-resistant connections
- Loadbreak functionality for safe maintenance operations
- Part of ABB Installation Products line for medium-voltage systems
Specifications
Amperage Rating | 200 A |
Application | The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Blue |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 161LR |
Size | Cable Insulation Diameter 0.635 inch to 0.905 inch |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 10.5 IN x 19.12 IN x 12.5 IN |
Package Dimensions (L x W x H) | 26.67 cm x 48.5648 cm x 31.75 cm |
Package Weight (Imperial) | 2.0700 L |
Package Weight (Metric) | 0.9390 kg |

161LRJS-D2240
200 Amp, 15kV, Loadbreak Elbow with Jacket Seal, Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
755LR-K0270
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
755LR-K0260-SG3
35kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 1.090 to 1.310 inch, Conductor Size 3/0 Compressed/Stranded or 4/0 Compact/Solid.
755LR-K0240
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
755LR-K0250-SG3
35kv, 600 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Aluminum Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.
755LR-K0230
35kV, 600 Amp Deadbreak Elbow without Test Point, Cable Insulation Diameter 1.090 to 1.310 inches (27.686 to 33.274 mm), Universal Aluminum Connector, For Cable Size #1 Stranded/Compressed, 1/0 Solid/Compact
755LR-K-5240-SG3
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.
755LR-K-0260-S
600 Amp, 35kV, 600 Series Deadbreak Elbow with Sealing Kit (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.Frequently Asked Questions
What is the Elastimold product and its voltage rating?
The product is an enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.
What standards and certifications does the elbow meet?
The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
How is a no-stick interface achieved with the elbow?
A no-stick interface is achieved when the enhanced Elastimold 200 amp loadbreak elbow is used with Elastimold bushings.
What standards and certifications does the elbow meet?
The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
How is a no-stick interface achieved with the elbow?
A no-stick interface is achieved when the enhanced Elastimold 200 amp loadbreak elbow is used with Elastimold bushings.
What is the Elastimold product and its voltage rating?
The product is an enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.
What standards and certifications does the elbow meet?
The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
What is the Elastimold product and its voltage rating?
The product is an enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.
How is a no-stick interface achieved with the elbow?
A no-stick interface is achieved when the enhanced Elastimold 200 amp loadbreak elbow is used with Elastimold bushings.
What is the Elastimold product and its voltage rating?
The product is an enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.
How to Install 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR and 162LR Loadbreak Elbow Connectors on various UD cables, including cable preparation, lug installation, elbow assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Wire strippers, Hotstick, Electrical tape
Supplies needed:
161LR/162LR Elbow Connector Kit (Housing, Lug, Probe, Lubricant), UD cable, No. 14 AWG (2.5mm) copper wire, Appropriate connector for neutral wires, Cable sealing kit (optional), Conductive copper tape (optional)
- Perform Safety Checks and Inspect Components
Ensure all apparatus is de-energized before beginning installation. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents for completeness and damage. Verify all components ensure proper fit with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; if resistance is encountered prior to full assembly, check for damage and replace the component.
- Prepare the Cable for Termination
Train the cable to ensure sufficient slack for ease of operation. Cut the cable squarely at the centerline of the bushing. Based on your specific cable type (e.g., non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the detailed instructions in the product documentation for removing the outer jacket and preparing the neutral or ground wires. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first at this stage.
- Strip Cable and Install Compression Lug
Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread the inhibitor, then position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield, ensuring the cut is straight, smooth, and squared, without cutting or nicking the insulation. Bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow and Neutral Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, being careful not to damage the eye. If the elbow was pre-ordered with a ground wire, proceed to the next step. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the installation.
- Connect Elbow to Bushing Plug
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with this step. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Securely fasten a full insulated “hotstick” type live-line tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing (at this point the contacts are approximately 4 inches apart). DO NOT HOLD IN THIS POSITION BUT IMMEDIATELY PUSH THE ELBOW HOME WITH A FAST, FIRM, STRAIGHT MOTION to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.