Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1M1310 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

ABB Installation Products 15PCJ1M1310 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786815746


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15PCJ1M1310 is a 15kV power cable joint engineered for medium-voltage applications requiring high-integrity, permanent splices in industrial, utility, and commercial power distribution systems. This joint accommodates cable insulation diameters from 1.370 inch to 1.630 inch and features a single-piece housing design that simplifies installation while reducing assembly time and potential failure points. The aluminum conductor is rated at 500 AWG solid, ensuring compatibility with standard medium-voltage power cables. The 15PCJ1M1310 is rated for 15kV use per IEEE Standard 404 and is suitable for both new installations and repairs to broken cables. It provides a fully shielded, fully submersible, straight splice solution that can be installed directly buried or in a vault. The pin-and-socket interlock design withstands cable pulls up to 500 lbs, maintaining electrical and water seal integrity at the cable entrance. This joint is ideal for power distribution systems, substations, and industrial facilities where reliable 15kV-rated connections are required. The single-piece housing eliminates multiple components, improving long-term reliability and reducing maintenance requirements. The ABB 15PCJ1M1310 is part of the Elastimold® 15PCJ1 series, a trusted solution for medium-voltage cable splicing and termination.
  • Rated for 15kV applications per IEEE Standard 404
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Single-piece housing design simplifies installation and reduces failure points
  • Aluminum conductor rated at 500 AWG solid for compatibility with standard medium-voltage cables
  • Fully shielded, fully submersible, and straight splice solution for new installations or repairs
  • Pin-and-socket interlock withstands cable pulls up to 500 lbs
  • Suitable for direct burial or vault installations

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
1.370" to 1.630"
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.

15PCJ2J1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 350.

15PCJ1K2290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 350.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

28PCJ1L1330

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.

25PCJ2M2310

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2L1300-J1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.

15PCJ1L2310

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum

69TCJS4-5-1

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1LM-1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

Frequently Asked Questions

What cable insulation diameter range does it accommodate?

The joint supports cable insulation diameters from 1.370 inch to 1.630 inch.

What type of conductor is used in this joint?

The joint uses a 500 AWG solid aluminum conductor.

What voltage rating does this cable joint support?

This cable joint is rated for 15kV medium-voltage applications.

Is this joint suitable for outdoor installations?

The product is designed for medium-voltage power cable connections, which may include outdoor applications depending on environmental conditions and additional protective measures.

What is the housing material of this cable joint?

The single-piece housing is designed for durability and ease of installation, typically made from high-strength insulating materials suitable for medium-voltage applications.

How to Install the Single Core Joint (1 PCJ Style)

This guide provides step-by-step instructions for the installation, wiring, and restoration of a permanent, fully screened single core joint for extruded solid dielectric cables.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Wire brush, Cleaning solvent, Clean cloth, Soldering iron, Constant force spring tool, Heat gun, Sandpaper

Supplies needed:

Joint Housing, PVC tape, Conductor splice (compression connector), Lubricant, Flat copper braid, Constant force spring, Mastic tape, Heat shrink

  1. De-energize and Inspect Apparatus

    Ensure all apparatus is de-energized before beginning installation. Inspect the joint housing and all components for any damage, verify their ratings, and confirm compatibility with the mating cables. DANGER: All apparatus must be de--energized during installation or removal of part(s). Do not touch or move energized products in the work area.

  2. Prepare Cables by Removing Jacket and Metallic Shield

    Train the cables into their final position and make a square cut, leaving approximately 5mm between them. Store the heat shrink tubing on either cable. Remove the outer jackets of both cables to the specified dimension (refer to dimension 'A' in the provided table). Carefully remove the cable's metallic tape screen for the specified distance (refer to dimension 'B' in the provided table) and secure the ends with PVC tape, ensuring the tape remains on the copper tape and does not overlap onto the non-metallic screen.

  3. Remove Non-Metallic Screen and Bevel Cable 1

    Carefully remove the cable's non-metallic screen from both cables to the specified point (refer to dimension 'D' in the provided table). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' to mark the splice location. WARNING: DO NOT NICK, CUT OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS.

  4. Temporarily Store Joint Housing on Cable 1

    Apply one layer of PVC tape (half-lapped) over the metallic screen of Cable 1, starting at the jacket and extending 10mm beyond the end of the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B' to locate the splice later. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and the PVC-taped portion of the cable metallic tape screen on Cable 1. Carefully store the joint housing onto Cable 1, sliding it up to the jacket. WARNING: THE FORWARD EDGE AND ANY OTHER SHARP EDGES OF THE METALLIC SCREEN MUST BE COVERED WITH PVC TAPE TO PREVENT DAMAGE TO THE JOINT HOUSING WHEN STORING IT ON PVC TAPED PORTION OF THE CABLE. DO NOT STORE SPLICE HOUSING ON EXPOSED METALLIC TAPE SHIELD.

  5. Remove Cable Insulation

    Carefully remove the cable insulation from both Cable 1 and Cable 2 to dimension 'E' (refer to the table). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.

  6. Install and Crimp Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both are fully seated. Before crimping, check the distance between the insulations; if it exceeds the 'Before' dimension in the provided table, do not proceed and review the instructions. Crimp the conductor splice according to the provided crimp chart. After crimping, remove any sharp protrusions or burrs and ensure all metal chips or filings are removed from the splice joint assembly area. Wipe off any excess inhibitor. Re-check the distance between cable insulations; if it exceeds the 'After' dimension in the table, do not proceed and redo the assembly.

  7. Clean and Lubricate Core Surfaces

    Clean the conductor, connector, and Cable 2 insulation surfaces thoroughly with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate the cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen. WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION.

  8. Position Joint Housing

    Slide the joint housing over the crimp connector until it is in its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on each side; these distances should be equal. Remove the PVC tape applied in Step C to expose 25mm of the copper tape.

  9. Restore Screen

    Wrap flat copper braid around each side of the joint housing, extending the ends over the metallic tape screen for 20mm on each side. Securely attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.

  10. Restore Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds, taking care not to burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tubing (stored in Step 2) over the center of the assembly and shrink it, starting at the center and working towards the ends. DO NOT BURN CABLES.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.