ABB - Installation Products 25PCJ2M2310 - 25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.

ABB Installation Products 25PCJ2M2310 25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786850310


Documents & Media
BrochureManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25kV Power Cable Joint Style 2 (SKU: 25PCJ2M2310) is engineered for reliable termination of medium voltage power cables. This joint is designed for copper conductors, specifically accommodating solid AWG size 500. The universal housing is a key feature, providing flexibility by accepting cable insulation diameters ranging from 1.370 inches to 1.630 inches. This specific range corresponds to the 'M' symbol in ABB's cable insulation diameter coding. This power cable joint is rated for 25kV, ensuring safe and secure connections in medium voltage distribution systems. The construction includes a universal housing and separate cable adapters, which facilitate a precise fit for the specified insulation diameter range, contributing to the overall integrity and performance of the electrical connection. The product is part of ABB's Installation Products line. Key Specifications: - SKU: 25PCJ2M2310 - Manufacturer: ABB - Installation Products - Voltage Rating: 25kV - Cable Insulation Diameter Range: 1.370" - 1.630" (Symbol 'M') - Conductor Type: Copper - Conductor Size: AWG Solid 500 - Housing Style: Universal - Adapter Type: Separate Cable Adapters Included components typically consist of the power cable joint housing, a connector, lubricant tube, installation instructions (e.g., IS-0332, IS-0179, IS-0180, IS-0182), and a crimp chart (e.g., CC-0038, CC-0039, CC-0042). The dimensional data for this style of joint indicates an overall length 'A' of 14 3/8 inches and a width 'B' of 2 25/32 inches. This product is suitable for applications requiring dependable medium voltage cable jointing.
  • 25kV voltage rating for medium voltage applications
  • Accommodates cable insulation diameters from 1.370" to 1.630" (Symbol 'M')
  • Designed for solid AWG 500 copper conductors
  • Universal housing with separate cable adapters for precise fit
  • Includes housing, connector, lubricant, instructions, and crimp chart

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 2
Size
21 inch long
Size
1.370 inch to 1.630 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ1M2330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2L1300-J1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.

15PCJ1L2310

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum

69TCJS4-5-1

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1LM-1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2L2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ2L1330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.

15PCJ1N2400

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.

Frequently Asked Questions

What is the purpose of the grounding eye?

The grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing the molded shield at ground potential.

What are the available voltage classes for PCJ joints?

The Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor types are compatible with PCJ joints?

PCJ power cable joints can be used with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What is the maximum conductor size supported by PCJ joints?

Elastimold PCJ power cable joints can accommodate conductor sizes up to 1250 kcmil for both copper and aluminum conductors.

What environments are suitable for PCJ joint installation?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What is the pull force rating for the interlock?

The pin-and-socket interlock on PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What is the continuous current rating for PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating for PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.