Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1LM-1330 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

ABB Installation Products 25PCJ1LM-1330 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786816804


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 25kV Power Cable Joint, SKU 25PCJ1LM-1330, is engineered for reliable electrical connections in medium-voltage applications. Designed for single-piece housing, this joint facilitates efficient and secure termination of power cables. It accommodates cable insulation diameters ranging from 1.280 inches to 1.430 inches, ensuring compatibility with a specific range of cable constructions. The joint is specifically designed for use with aluminum conductors, supporting a stranded conductor size of 500 AWG. This specification is critical for high-capacity power transmission and distribution systems where robust and dependable connections are paramount. The Style 1 joint configuration simplifies installation while maintaining the integrity of the cable's insulation and shielding. ABB's Installation Products division is known for delivering solutions that meet stringent industry standards for safety and performance. This product is an essential component for utility, industrial, and commercial power infrastructure projects requiring dependable medium-voltage cable terminations. Its design focuses on ensuring electrical continuity and mechanical strength, crucial for preventing outages and ensuring operational safety in demanding environments.
  • 25kV rated power cable joint
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 1.280" to 1.430"
  • Designed for 500 AWG stranded aluminum conductors
  • ABB Installation Products quality and reliability

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
25PCJ1
Size
14-3/8 inch long
Size
1.280 inch to 1.430 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.

25PCJ2M2310

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2L2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ2L1330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.

15PCJ1N2400

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

25PCJ1J2260

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 4, - 4

69TCJS4-3-4

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 4, - 4
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ1M2360

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

15PCJ2M1410-L1360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

Frequently Asked Questions

What cable insulation diameter range does this joint support?

This ABB 25kV Power Cable Joint supports cable insulation diameters ranging from 1.280 inches to 1.430 inches.

What conductor type and size is this joint designed for?

This joint is designed for 500 AWG stranded aluminum conductors.

What is the voltage rating of this power cable joint?

This ABB power cable joint is rated for 25kV.

What is the housing style of this cable joint?

This ABB power cable joint features a single-piece housing.

How to Install the 15/25/35PCJ1 Straight Joint

This guide provides step-by-step instructions for installing the 15/25/35PCJ1 straight joint, a permanent, fully shielded, and submersible joint for connecting aluminum to aluminum and/or aluminum to copper wire-shielded cables.

Estimated time: 2h

Tools needed:

Wire-brush, Crimping tool, Cable stripping tool, Cable cutting tool, Measuring tape, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Electrical connectors, DELTECt Cable ties (TYD5135), No. 14 AWG Copper wire or equivalent

  1. Ensure Safety and Inspect Components

    Before beginning, ensure all apparatus are de-energized. Do not touch or move energized products in the work area. Inspect all parts for damage, proper rating, and compatibility with mating parts and cable. Read the entire installation instructions thoroughly before proceeding.

  2. Prepare Cables for Joint Centerline

    Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint. This ensures sufficient length for shield wires to rejoin. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables precisely at the joint centerline.

  3. Prepare Cable 1 and Position Joint Housing

    Taper the edge of Cable 1's insulation shield from at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the housing onto Cable 1, pushing it up to the shield wires for temporary storage.

  4. Remove Cable Insulation and Shield

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. Refer to the provided dimension table for 'X' and 'Y' measurements based on conductor size (e.g., 2 1/2” (64mm) for 'Y' and 6 1/4” (159mm) for 'X' for 500-750 MCM). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.

  5. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table; if it exceeds, redo the assembly. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs generated during crimping, ensuring all metal chips/filings are cleared from the splice and joint assembly area.

  6. Lubricate and Position Joint Housing

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield. Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  7. Secure Grounding and Shield Wires

    For 35kV installations ONLY, install two DELTECt Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge and then 1/4 inch (6mm) from the first, with offset locking heads. Use a T&B WT3D tool to tighten and trim. Also for 35kV, remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector.

  8. Reconstruct Cable Jacket

    Where applicable, reconstruct the cable jacket over both cables and the joint housing to complete the installation and provide environmental protection.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.