Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1L2310 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.

ABB Installation Products 15PCJ1L2310 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786847808


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Installation Products 15kV Power Cable Joint, SKU 15PCJ1L2310, is designed for reliable termination of copper conductor power cables. It features a single-piece housing for simplified installation and robust protection. The joint is engineered to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches, ensuring compatibility with a specific range of cable constructions. It is suitable for use with solid copper conductors sized at 500 AWG. This product is essential for ensuring the integrity and safety of medium-voltage power distribution systems. The UNSPSC code for this item is 39121452. ABB is a recognized manufacturer in electrical infrastructure components, providing dependable solutions for power transmission and distribution networks. The single-piece housing design contributes to a streamlined installation process, reducing labor time and potential for errors in the field. This joint is built to maintain the electrical insulation and mechanical integrity of the cable connection under operational stress. Its specific application is in medium-voltage power cable splicing and termination where a 15kV rating is required and the cable parameters align with the specified insulation diameter and conductor size.
  • 15kV Power Cable Joint, Style 1
  • Single-piece housing for efficient installation
  • Accommodates cable insulation diameter: 1.180" - 1.465"
  • Designed for 500 AWG solid copper conductors
  • Manufacturer: ABB - Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
1.180 inch to 1.465 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.

15PCJ2J1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum

69TCJS4-5-1

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1LM-1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2L2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ2L1330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.

15PCJ1N2400

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

25PCJ1J2260

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 4, - 4

69TCJS4-3-4

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 4, - 4

Frequently Asked Questions

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the short-time current rating?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the continuous current rating?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the short-time current rating?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the continuous current rating?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the Single Core Joint (15PCJ1L2310)

This guide provides step-by-step instructions for the permanent installation of a fully screened, submersible single core joint (15PCJ1L2310) for extruded solid dielectric cables. It covers cable preparation, connector installation, and joint housing assembly.

Estimated time: 2h

Tools needed:

Cable stripping tools, Wire brush, Crimping tool, Deburring tool, Soldering equipment or Constant force spring tool, Sanding tool, Heat gun, Measuring tape

Supplies needed:

PVC tape, Conductor splice, Lubricant (supplied), Flat copper braid, Mastic tape, Heat shrink, Cleaning solvent

  1. Prepare for Installation and Ensure Safety

    Check the contents of the package to ensure they are complete and undamaged. Check all components to ensure proper fit with the cable and/or mating products. Read the entire installation instructions before starting. Have all required tools at hand and maintain cleanliness throughout the procedure. DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Cable Jackets and Metallic Shields

    Train the cables into their final position and square cut, leaving approximately 5mm between cables. Store the heat shrink on either cable. Remove the jackets of both cables to the dimensions shown in the documentation (A, B, C). Carefully remove the cable metallic tape screen for the distance shown and secure the ends with PVC tape. Keep the PVC tape on the copper tape and do not overlap onto the non-metallic screen.

  3. Prepare Non-Metallic Screens and Mark Cables

    WARNING: DO NOT NICK, CUT OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen from both cables to the point specified. Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' from the end of both cables, DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' to locate the splice later.

  4. Temporarily Store Joint Housing on Cable 1

    Beginning at the jacket and proceeding 10mm beyond the end of the metallic screen, apply one layer (half lapped) of PVC tape over the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC taped portion of the cable metallic tape screen on Cable 1. WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing. Store the housing onto Cable 1 up to the jacket. DO NOT store the splice housing on the exposed metallic tape shield.

  5. Remove Cable Insulation

    WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. Remove the cable insulation from both cables to dimension 'E' as specified in the documentation.

  6. Install and Crimp the Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between insulations; if it exceeds the 'Before' dimension (F Max) in the table, DO NOT PROCEED, review instructions and redo assembly. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs. Metal chips or filings must be removed from the splice joint assembly area. Wipe off all excess inhibitor. Check the distance between cable insulations; if it exceeds the 'After' dimension (F Max) in the table, DO NOT PROCEED, review instructions and redo assembly.

  7. Clean and Lubricate Cable Cores

    WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth. Always wipe towards the screen end. Lubricate cable insulation surfaces using the lubricant supplied. Always wipe toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.

  8. Position the Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker; the distance 'X' should be equal on each side of the joint housing. Remove the PVC tape applied in Step C to expose 25mm of copper tape.

  9. Restore the Screen

    Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.

  10. Restore the Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds. DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.