ABB - Installation Products 69TCJS4-5-1 - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum
ABB - Installation Products

69TCJS4-5-1

UPC: 783786845040


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

This ABB 69 kV Transmission Cable Joint, SKU 69TCJS4-5-1, is engineered for reliable power transmission infrastructure. Designed with a Shieldbreak connection type and Housing Style 4, this joint ensures secure and efficient termination for high-voltage cables. The housing is specifically sized at Size 5, accommodating a defined range of cable diameters and configurations. Constructed with an Aluminum connector, it provides excellent conductivity and corrosion resistance, critical for long-term performance in demanding electrical systems. This joint is suitable for applications requiring robust and dependable connections at 69 kV, such as in substations, power generation facilities, and transmission networks. The Shieldbreak design is crucial for managing electrical stress at the cable shield termination, preventing premature failure and ensuring operational safety. ABB's Installation Products division delivers components that meet stringent utility standards. The Aluminum construction offers a cost-effective yet durable solution for critical power infrastructure projects. Its specific housing size and style are designed for precise fitment and ease of installation, minimizing downtime during maintenance or new construction. For utilities and contractors seeking dependable 69 kV cable jointing solutions, this ABB product offers a specification-driven approach to network integrity. The UNSPSC code for this product is 39121452.
  • 69 kV Voltage Rating for high-voltage transmission applications.
  • Shieldbreak connection type for effective electrical stress management.
  • Housing Style 4 with Size 5 for precise cable termination.
  • Aluminum connector material for optimal conductivity and corrosion resistance.
  • Manufactured by ABB - Installation Products for reliable infrastructure.

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.

69TCJS4-5-4

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1LM-1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ2L2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ2L1330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.

15PCJ1N2400

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

25PCJ1J2260

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 4, - 4

69TCJS4-3-4

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 4, - 4
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ1M2360

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.

Frequently Asked Questions

Are there safety precautions for installation?

Yes, refer to local code for required Personal Protective Equipment (PPE) during installation.

What is the minimum corona extinction voltage?

The minimum corona extinction voltage for 69 kV joints is 60 kV, with a 3 pC sensitivity.

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for these joints is 90 °C.

What is the BIL rating for 69 kV joints?

The Basic Impulse Level (BIL) rating for 69 kV joints is 350 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

What are the dimensions of the 69TCJS4-5-1 joint housing?

The joint housing for 69TCJS4-5-1 has a diameter of 7.22 in (183.4mm) and a length of 32.00 in (812.8mm).

What is the nominal voltage class for 69TCJS4-5-1?

The nominal voltage class for the 69TCJS4-5-1 is 69 kV, with a maximum system voltage of 72.5 kV.

What cable insulation diameter is compatible with 69TCJS4-5-1?

The 69TCJS4-5-1 joint is designed for solid dielectric cables with insulation diameters ranging from 2.900 in to 3.290 in (73.7mm to 83.6mm).

What are the dimensions of the 69TCJS4-5-1 joint housing?

The joint housing for 69TCJS4-5-1 has a diameter of 7.22 in (183.4mm) and a length of 32.00 in (812.8mm).

What is the BIL rating for 69 kV joints?

The Basic Impulse Level (BIL) rating for 69 kV joints is 350 kV (1.2 x 50μs; 10 positive, 10 negative impulses).

Are there safety precautions for installation?

Yes, refer to local code for required Personal Protective Equipment (PPE) during installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.